PV-670508-000 Amphenol Industrial Operations, PV-670508-000 Datasheet

CRIMP TOOL H4

PV-670508-000

Manufacturer Part Number
PV-670508-000
Description
CRIMP TOOL H4
Manufacturer
Amphenol Industrial Operations
Series
Helios H4r
Datasheets

Specifications of PV-670508-000

Tool Type
Hand Crimper
Features
Side Entry
For Use With/related Products
Photovoltaic (Solar Panel) Connectors
For Use With
956-1008 - CONN H4 MALE HALF 14AWG/2.5MM2956-1007 - CONN H4 FEMALE HALF 14AWG/2.5MM2956-1006 - CONN H4 MATED PAIR 14AWG/2.5MM2956-1005 - CONN H4 MALE HALF 10AWG/6MM2956-1004 - CONN H4 FEMALE HALF 10AWG/6MM2956-1003 - CONN H4 MATED PAIR 10AWG/6MM2956-1002 - CONN H4 MALE HALF 12AWG/4MM2956-1001 - CONN H4 FEMALE HALF 12AWG/4MM2956-1000 - CONN H4 MATED PAIR 12AWG/4MM2
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
956-1010
H4TC0000
Amphenol
Assembly Instruction for the Helios H4 PV Connector
Connectors must not be connected or disconnected under load!
www.amphenol-industrial.com

PV-670508-000 Summary of contents

Page 1

... Amphenol Assembly Instruction for the Helios H4 PV Connector Connectors must not be connected or disconnected under load! www.amphenol-industrial.com ...

Page 2

... Amphenol Helios H4 components come pre-assembled and the caps are loose. And the whole connector will include the male side and female side. PV-100508-F – Female side Connector PV-100508-M – Male side Connector www.amphenol-industrial.com ...

Page 3

Amphenol 1. Assembly Instruction for the male side and female side connector 1.1 Strip cable .276 inches (9/32”) - (7mm) and be careful NOT to nick conductors. Amphenol specified strip tool can be used in this step. Adjust the striper ...

Page 4

Amphenol 1. Assembly Instructions for the male side connector and female side. 1.2 Insert striped cable into contact barrel and insure all conductor strands are captured in the contact barrel and the conductors are visible in the contact barrel observation ...

Page 5

Amphenol 1. Assembly Instructions for the male side connector and female side. 1.3 Crimp contact barrel by using the hex crimping die. See below figures. Crimped pin contact Amphenol specified crimping tool can be used in this step. Put the ...

Page 6

... Assembly Instructions for the male side connector and female side. 1.4 Insert contact cable assembly into back of male and female connector. A “click” should be heard or felt when the contact cable assembly is seated correctly. PV-090508-F – Female side Connector PV-090508-M – Male side Connector www.amphenol-industrial.com See below figures. ...

Page 7

... Assembly Instructions for the male side connector and female side. 1.5 Wrest the cap by using the torque to Amphenol specified wrench tool can be used in this step. Here 2 wrench tools are used, one is by hand for holding the connector by hand, another is also by hand to wrest the cap down until the tool starts to snap over ...

Page 8

Amphenol 2. Mate and separate Helios H4 connector 2.1 After wrest the cap tightly, align the 2 half connectors and mate them together by hand until a “click” is heard or felt. 2.2 When the separation of connector is necessary, ...