182K9 Hammond Manufacturing, 182K9 Datasheet

TRANSFORMER TOROID 18VCT 1.67A

182K9

Manufacturer Part Number
182K9
Description
TRANSFORMER TOROID 18VCT 1.67A
Manufacturer
Hammond Manufacturing
Type
Dual Primaryr
Series
182r
Datasheets

Specifications of 182K9

Maximum Power
30 VA
Primary Winding(s)
Dual
Secondary Winding(s)
Dual, No Center Tap
Series Output Voltage @ Current
18 VAC @ 1.67A
Parallel Output Voltage @ Current
9 VAC @ 3.34A
Mounting Type
Chassis Mount
Primary Voltage Rating
117 V / 234 V
Secondary Voltage Rating
18 V
Mounting Style
Bolt In
Dimensions
40.6 mm H
Product
Toroidal Power Transformers
Height
40.6 mm
Number Of Outputs
2
Termination Style
Quick Connects
Brand/series
182 Series
Configuration
Toroidal
Current, Secondary
3.34/1.67 A
Frequency
50/60 Hz
Length, Lead
8 "
Number Of Outlets
2
Phase
1
Power, Rating
30 VA
Primary Type
Dual
Standards
UL, CSA, CE
Termination
Leadwires
Voltage, Primary
117/234 VAC
Voltage, Secondary
9/18 VAC
Weight
1.12 lbs.
Power Rating
30VA
Secondary Voltages
2 X 9V
Secondary Current Nom
3.34A
Transformer Mounting
Panel
Secondary Current Aac
3.34A
Output Current, Secondary Series
1.67A
Primary Voltages
2 X 117V
Rohs Compliant
Yes
Current Rating
1.67 Series/3.34 Parallel A
Leaded Process Compatible
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Toroidal (182 Series)
Primary
Dual Secondary
Blk
Wht
Brn
Orn
Low profile, lightweight, cool running - due to high
efficiency toroidal design
Dual 117/234 VAC primary, 50/60 Hz. operation
Center single hole mounting
Supplied with two rubber insulating pads, one metal
centering washer and all mounting hardware
Center bolt size is 10-24 x 3 inch RHMS zinc plated
Minimum 8" long flexible leads
Due to toroid design - no electrostatic shield required
Hi-Pot test of 4,000V RMS between primary &
secondary
CSA certified to C22.2 #66 - CSA file #209651
UL recognized to UL506 - UL file #E207860
CE certified to IEC950
For wiring diagrams - visit our website:
Schematic
©
www.hammondmfg.com
St. Laurent, Quebec (514) 343-9010
Cheektowaga, NY (716) 630-7030
Guelph, Ontario (519) 822-2960
Transformer Schematics
Secondary
TOROIDAL POWER
Red
Blu
Gry
Yel
TRANSFORMERS
CANADA
USA
Primary
Single Secondary
Blk
Wht
Brn
Orn
Schematic
www.hammondmfg.com
Secondary
Red
Blu
34
Dim.
Ref.
B
C
D
G
H
K
M
A
E
F
J
L
I
Outside Diameter
Dimension Table
(Inches)
3.98
4.43
4.97
5.06
5.50
6.10
6.40
6.50
7.20
3.20
2.95
3.63
3.73
Queenstown, Australia 61-8-8240-2244
Basingstoke, UK 01256 812812
AUSTRALIA
(Inches)
Height
EUROPE
1.25
1.60
1.73
1.52
1.68
1.73
1.90
2.27
2.21
3.10
3.10
3.50
3.50
Weight
(Lbs.)
10.38
13.53
16.49
24.97
0.76
1.12
1.67
2.15
2.84
3.87
4.96
5.58
8.46

Related parts for 182K9

182K9 Summary of contents

Page 1

... Toroidal (182 Series) TOROIDAL POWER TRANSFORMERS • Low profile, lightweight, cool running - due to high efficiency toroidal design • Dual 117/234 VAC primary, 50/60 Hz. operation • Center single hole mounting • Supplied with two rubber insulating pads, one metal centering washer and all mounting hardware • ...

Page 2

... C. 182N6 50 12V C.T. @ 4.17A 6V @ 8.34A 182Q6 80 12V C.T. @ 6.67A 6V @ 13.34A 182H9 15 18V C.T. @ .83A 9V @ 1.66A 182K9 30 18V C.T. @ 1.67A 9V @ 3.34A 182M9 50 18V C.T. @ 2.78A 9V @ 5.56A 182N9 80 18V C.T. @ 4.44A 9V @ 8.88A 182Q9 120 18V C.T. @ 6.67A 9V @ 13.34A 182G12 15 24V C ...

Related keywords