Z4LC-S2840

Manufacturer Part Number
Z4LC-S2840
Description
SENS NPN 28MM BEAM 40MM DIST
Manufacturer
Omron
Datasheet

Specifications of Z4LC-S2840

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
Z4LCS2840
Z4LC
Explanation of Each Mode
J MEASUREMENT MODES
Select one of the following measurement modes according to the measurement conditions.
(1.) One-side Interruption Mode 1 (First Dark Edge)
Measures the width from the edge of the beam to the end of the
first dark section. (For meander detection, orientation flat
positioning, etc.)
(2.) One-side Interruption Mode 2 (First Light Edge)
Measures the width from the edge of the beam to the end of the
first light section. (For gap measurement, etc.)
(3.) Bar Diameter Measurement Mode (Diameter)
Measures the width from the first edge to the last edge of the
beam. (For measuring the diameter of bars, etc.)
(4.) Bar Position Measurement Mode (Position)
Measures the center point between the first edge and the last
edge of the beam. (For position detection of bars, etc.)
(5.) Pin Pitch Determination Mode (Pin Pitch)
Measures the pin pitch and determines if pins are centered or
not. It is passed if all pin pitch are within the tolerance and
rejected if not. (Pin number: 14 max.)
4
(6.) Pin Diameter Determination Mode (Pin Diameter)
Determines whether pin diameters are within a set range.
(Pin number: 14 max.)
(7.) Specified Edge Measurement Mode (Edge)
Measures the width of two specified edges.
(8.) Wire Position Detection Mode (Fine Line)
Measures the position of fine lines with minimum of 0.1 dia. The
measurement details are the same as that of bar position
measurement mode. (For positioning of wires more than 0.1 dia.)
(9.) Transparent Object Edge Detection Mode (Glass)
Detects the edge of glass boards and transparent sheets. The
distance between the upper edge of the beam and the edge of
the transparent object is measured. (For detecting edges of
transparent objects.)
Forced Zero Function
The displayed value can be set to zero by the ZERO/ENT Key on
the front panel or external input.
Suitable for the discrimination of standard workpieces.
Analog Output Setting Function
The range of analog output can be set within the measurement
width 28 mm.
Enable Mode Measurement Function
The processing item (i.e. maximum, minimum, maximum minus
minimum, or average) can be set. The set item is calculated and
output while the enable mode signal is input.
Suitable for the measurement of bar movement.