EEU-FA1V471 Panasonic - ECG, EEU-FA1V471 Datasheet - Page 7

no-image

EEU-FA1V471

Manufacturer Part Number
EEU-FA1V471
Description
CAP 470UF 35V FA SER ALUM LYTC
Manufacturer
Panasonic - ECG
Series
FAr
Datasheet

Specifications of EEU-FA1V471

Capacitance
470µF
Voltage Rating
35V
Tolerance
±20%
Lifetime @ Temp.
3000 Hrs @ 105°C
Operating Temperature
-55°C ~ 105°C
Features
General Purpose
Ripple Current
1.44A
Impedance
45 mOhm
Mounting Type
Through Hole
Package / Case
Radial, Can
Size / Dimension
0.394" Dia (10.00mm)
Height
0.984" (25.00mm)
Lead Spacing
0.197" (5.00mm)
Lead Free Status / RoHS Status
Request inventory verification / Request inventory verification
Esr (equivalent Series Resistance)
-
Surface Mount Land Size
-
Other names
EEUFA1V471
P5644A
Design, Specifications are subject to change without notice. Ask factory for technical specifications before purchase and/or use.
Whenever a doubt about safety arises from this product, please inform us immediately for technical consulation without fail.
(5)Clearance for Case Mounted Pressure
(6)Clearance for Seal Mounted Pressure
(7)Wiring Near the Pressure Relief Vent
(8)Circuit Board Patterns Under the Capacitor
(9)Screw Terminal Capacitor Mounting
1.6Electrical Isolation of the Capacitor
1.7 Capacitor Sleeve
The vinyl sleeve or laminate coating is intended for
marking and identification purposes and is not meant
to electrically insulate the capacitor.
The s l e e v i n g may split or crack if immersed into
solvents such as toluene or xylene, and then exposed
to high temperatures.
Always consider safety when designing equipment
and circuits. Plan for worst case failure modes such
as short circuits and open circuits which could occur
during use.
require sufficient clearance to allow for proper vent
operation. The minimum clearances are dependent
on capacitor diameters as follows.
Completely isolate the capacitor as follows.
axially leaded B types) and between the anode
(1)Provide protection circuits and protection devices
(2)Design redundant or secondary circuits where
Between the cathode and the case (except for
Relief Vents
Capacitors with case mounted pressure relief vents
A hole in the circuit board directly under the seal
vent location is required to allow proper release
of pressure.
Avoid locating high voltage or high current wiring
or circuit board paths above the pressure relief
vent. Flammable, high temperature gas exceeding
100 C may be released which could dissolve the
wire insulation and ignite.
Avoid circuit board runs under the capacitor as
electrolyte leakage could cause an electrical short.
Do not orient the capacitor with the screw terminal
side of the capacitor facing downwards.
Tighten the terminal and mounting bracket screws
w i t h i n t h e t o r q u e r a n g e s p e c i f i e d i n t h e
specification.
terminal and other circuit paths.
Between the extra mounting terminals (on T types)
and the anode terminal, cathode terminal, and
other circuit paths.
f40 mm or greater: 5 mm minimum
Relief Vents
f6.3 to f16 mm
f18 to f35 mm
to allow safe failure modes.
possible to assure continued operation in case of
main circuit failure.
: 2 mm minimum,
: 3 mm minimum.
– EE19 –
2. Capacitor Handling Techniques
2.1 Considerations Before Using
(1) Capacitors have a finite life. Do not reuse or
(2) Transient recovery voltage may be generated in
(3) Capacitors stored for long periods of time may
(4) If capacitors are dropped, they can be damaged
(5) Dented or crushed capacitors should not be
2.2 Capacitor Insertion
(1) Verify the correct capacitance and rated voltage
(2) Verify the correct polarity of the capacitor before
(3) Verify the correct hole spacing before insertion
(4) Ensure that the auto insertion equipment lead
2.3 Manual Soldering
(1) O b s e r v e t e m p e r a t u r e a n d t i m e s o l d e r i n g
(2) If lead wires must be formed to meet terminal
(3) If a soldered capacitor must be removed and
(4) Aviod touching the tip of the soldering iron to the
recycle capacitors from used equipment.
the capacitor due to dielectric absorption. If
required, this voltage can be discharged with a
resistor with a value of about 1 k .
exhibit an increase in leakage current. This can
be corrected by gradually applying rated voltage
in series with a resistor of approximately 1 k .
mechanically or electrically. Avoid using dropped
capacitors.
used. The seal integrity can be compromised
and loss of electrolyte/shortened life can result.
of the capacitor.
inserting.
(land pattern size on chip type) to avoid stress
on the terminals.
clinching operation does not stress the capacitor
leads where they enter the seal of the capacitor.
For chip type capacitors, excessive mounting
pressure can cause high leakage current, short
circuit, or disconnection.
specifications or do not exceed temperatures of
350 C for 3 seconds or less.
board hole spacing, avoid stress on the leadwire
where it enters the capacitor seal.
reinserted, avoid excessive stress to the capacitor
leads.
capacitor, to prevent melting of the vinyl sleeve.
Aluminum Electrolytic Capacitor
Mar. 2005

Related parts for EEU-FA1V471