GRM319R71H103KA01D Murata Electronics North America, GRM319R71H103KA01D Datasheet - Page 127

CAP CER 10000PF 50V 10% X7R 1206

GRM319R71H103KA01D

Manufacturer Part Number
GRM319R71H103KA01D
Description
CAP CER 10000PF 50V 10% X7R 1206
Manufacturer
Murata Electronics North America
Series
GRMr
Datasheet

Specifications of GRM319R71H103KA01D

Capacitance
10000pF
Voltage - Rated
50V
Tolerance
±10%
Temperature Coefficient
X7R
Mounting Type
Surface Mount, MLCC
Operating Temperature
-55°C ~ 125°C
Applications
General Purpose
Package / Case
1206 (3216 Metric)
Size / Dimension
0.126" L x 0.063" W (3.20mm x 1.60mm)
Thickness
0.85mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Ratings
-
Lead Spacing
-
Other names
490-1774-2
GRM42-6X7R103K050AD

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
GRM319R71H103KA01D
Manufacturer:
MURATA
Quantity:
460 000
!Note
• This PDF catalog is downloaded from the website of Murata Manufacturing co., ltd. Therefore, it’s specifications are subject to change or our products in it may be discontinued without advance notice. Please check with our
• This PDF catalog has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering.
sales representatives or product engineers before ordering.
!Note
!Note
No.
13
14
15
Mounting for testing: The capacitors should be mounted on the substrate as shown below using die bonding. when tests No. 11 to 15 are performed.
GMD Series Specifications and Test Methods (1)
Continued from the preceding page.
Humidity
(Steady State)
Humidity
Load
High
Temperature
Load
1. This Specifications and Test Methods is downloaded from the website of Murata Manufacturing co.,ltd. Therefore, it's specifications are subject to change or our products in it may be discontinued without advance notice.
• Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this catalog to prevent smoking and/or burning, etc.
0.
• This catalog has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering.
2. This Specifications and Test Methods has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product
0.
Please check with our sales representatives or product engineers before ordering.
specifications before ordering.
Item
Appearance No defects or abnormalities.
Capacitance
Change
D.F.
I.R.
Appearance No defects or abnormalities.
Capacitance
Change
D.F.
I.R.
Appearance No defects or abnormalities.
Capacitance
Change
D.F.
I.R.
R7 : Within 12.5%
R7 :
W.V. 25Vmin. : 0.05 max.
W.V. 16/10V : 0.05 max.
More than 1,000M or 50 · F
(whichever is smaller)
R7 : Within 12.5%
R7 :
W.V. 25Vmin. : 0.05 max.
W.V. 16/10V : 0.05 max.
More than 500M or 25 · F
(whichever is smaller)
R7 : Within 12.5%
R7 :
W.V. 25Vmin. : 0.05 max.
W.V. 16/10V : 0.05 max.
More than 1,000M or 50 · F
(whichever is smaller)
Alumina substrate
When no "*" is added in PNs table, please refer to GMD Series Specifications and Test Methods (1).
Specifications
Gold land
When "*" is added in PNs table, please refer to GMD Series Specifications and Test Methods (2).
GMD Series Specifications and Test Methods (1)
Gold wire
Set the capacitor for 500 12 hours at 40 2 C, in 90 to 95%
humidity.
Take it out and set it for 24 2 hours at room temperature, then
measure.
Apply the rated voltage for 500 12 hours at 40 2 C, in 90 to
95% humidity and set it for 24 2 hours at room temperature,
then measure. The charge/discharge current is less than
50mA.
A voltage treatment should be given to the capacitor, in which a
DC voltage of 200% the rated voltage is applied for one hour at
the maximum operating temperature; 3 C then it should be set
for 24 2 hours at room temperature and the initial measurement
should be conducted.
Then apply the above-mentioned voltage continuously for
1000 12 hours at the same temperature, remove it from the
bath, and set it for 24 2 hours at room temperature, then
measure. The charge/discharge current is less than 50mA.
Alumina substrate
Capacitor
Gold land
Die bond
Test Method
Gold wire
125
C02E.pdf
10.12.20