BCCM6033SQ Cooper/Bussmann, BCCM6033SQ Datasheet - Page 163

no-image

BCCM6033SQ

Manufacturer Part Number
BCCM6033SQ
Description
FUSEBLOCK CLASS CC 13/32X1-1/2"
Manufacturer
Cooper/Bussmann
Series
BCCMr
Type
Blockr
Datasheet

Specifications of BCCM6033SQ

Fuse Size
Class CC
Number Of Circuits
3
Mounting Type
Chassis Mount
Termination Style
Screw Terminal
Current Rating
20A
Product
Block
Fuse Size / Group
Class CC
Voltage Rating
600 Volts
Mounting Style
Screw
Body Material
Thermoplastic
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Electrical Characteristics
Part Number Construction
Catalog Number Cross Reference
ECL055-10E
ECL055-20E
ECL055-40E
Example
Bussmann
Number
ECL055-15E
ECL055-25E
ECL055-30E
ECL055-50E
ECL055-65E
ECL055-80E
ECL055-100E
ECL055-125E
ECL055-150E
ECL055-200E
ECL055-250E
ECL055-300E
ECL055-400E
ECL055-450E
ECL055-500E
ECL055-600E
EBI055-750E
EBI055-900E
Bussmann
ECL055-10E
ECL055-15E
ECL055-20E
ECL055-25E
ECL055-30E
ECL055-40E
ECL055-50E
ECL055-65E
ECL055-80E
ECL055-100E
ECL055-125E
ECL055-150E
ECL055-200E
ECL055-250E
ECL055-300E
ECL055-400E
ECL055-450E
ECL055-500E
ECL055-600E
EBI055-750E
EBI055-900E
Medium Voltage Fuses and Fuse Links
E-Rated Medium Voltage Fuses: CL-14 & Bolt-In
Catalog Symbol
For complete specification data, call Bussmann Information Fax ~ 636.527.1450
ECL
AO55B3DORO-750E
AO55B3DORO-900E
A055C1DORO-100E
A055C1DORO-125E
A055C1DORO-150E
A055C1DORO-200E
A055C1DORO-250E
A055C1DORO-300E
A055C1DORO-400E
A055C2DORO-450E
A055C2DORO-500E
A055C2DORO-600E
A055C1DORO-10E
A055C1DORO-15E
A055C1DORO-20E
A055C1DORO-25E
A055C1DORO-30E
A055C1DORO-40E
A055C1DORO-50E
A055C1DORO-65E
A055C1DORO-80E
Ampere
Rating
100E
125E
150E
200E
250E
300E
400E
450E
500E
600E
750E
900E
Ferraz-Shawmut
New Catalog #
10E
15E
40E
80E
20E
25E
30E
50E
65E
Voltage Rating
Voltage
5.5kV
5.5kV
5.5kV
5.5kV
5.5kV
5.5kV
5.5kV
5.5kV
5.5kV
5.5kV
5.5kV
5.5kV
5.5kV
5.5kV
5.5kV
5.5kV
5.5kV
5.5kV
5.5kV
5.5kV
5.5kV
055 = 5.5 kV
055
Max Sym.
63kA
63kA
63kA
63kA
63kA
63kA
63kA
63kA
63kA
63kA
63kA
63kA
63kA
63kA
63kA
63kA
63kA
63kA
63kA
63kA
63kA
IR
Ferraz-Shawmut
225-007-937
225-007-938
225-007-939
225-007-940
225-007-941
225-007-942
225-007-943
225-007-944
225-007-945
225-007-946
225-007-947
225-007-948
225-007-949
225-007-950
225-007-951
225-007-952
225-007-953
225-007-954
225-007-955
A055X750E-4
A055X900E-4
Old Catalog #
Ampere Rating
Barrels
# of
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
2
2
2
3
3
500E
Figure #
1
1
1
1
1
1
1
1
1
1
1
1
2
2
3
3
3
3
3
4
4
Clip-Lock
Clip-Lock
Clip-Lock
Clip-Lock
Clip-Lock
Clip-Lock
Clip-Lock
Clip-Lock
Clip-Lock
Clip-Lock
Clip-Lock
Clip-Lock
Clip-Lock
Clip-Lock
Clip-Lock
Clip-Lock
Clip-Lock
Clip-Lock
Clip-Lock
Bolt-In
Bolt-In
Style
Current-limiting medium voltage fuses are
classified into three categories:
Full Range - defined by ANSI as “a fuse capable of inter-
rupting all currents from the maximum rated interrupting
current down to the minimum continuous current that caus-
es melting of the fusible element(s), when the fuse is applied
at the maximum ambient temperature specified by the man-
ufacturer.” It is able to interrupt any normal 60 cycle current
that will melt its element.
General Purpose - defined by ANSI C37.40 as “a fuse
capable of interrupting all currents from the maximum rated
interrupting current down to the current that causes melting
of the fusible element in one hour.” Not all currents fall with-
in this range. It is possible to receive an overcurrent lower
than the value given by the one hour criterion.
Back-up - defined by ANSI C37.40 as “a fuse capable of
interrupting all currents from the maximum rated interrupting
current down to the rated minimum interrupting current.”
The minimum rated interrupting current is the lowest current
that the fuse will be able to clear properly. This creates a
need to place a low current interrupting device in series with
the back-up rated fuse.
CATALOG SYMBOL: ECL055 & EBI055
E-RATED MEDIUM VOLTAGE FUSES:
FOR TRANSFORMER AND FEEDER PROTECTION
VOLTAGE RATING: 5.5 KV
INTERRUPTING RATING: 63KA Maximum Sym.
CURRENT LIMITING
CONSTRUCTION:
• Silver element in a double concentric helical configuration
• Silica filler
• Silver plated copper terminals and endcaps
• Filament wound, glass epoxy fuse tube
FEATURES:
• General Purpose Fuses. Bussmann’s medium voltage
• Clip-lock and bolt-in style available in double and triple
• Indoor and Outdoor Usage. The filament wound, glass
• Open Fuse Indication. Indicator travel distance is 16mm.
• Operating Frequency: 50/60 Hz
fuses provide general purpose protection and are capable of
interrupting fault currents up to 63,000A RMS sym.
barrel fuse designs.
epoxy fuse tube provides UV and moisture protection for the
fuse. This makes Bussmann’s medium voltage fuses suitable
for both indoor and outdoor applications.
Meets E requirements per ANSI C37.46
Meets General Purpose requirements per ANSI C37.40
Bussmann
Data Sheet: 9002
159
®

Related parts for BCCM6033SQ