Specifications of Z8F2422VS020SG

Core Processor
Z8
Core Size
8-Bit
Speed
20MHz
Connectivity
I²C, IrDA, SPI, UART/USART
Peripherals
Brown-out Detect/Reset, DMA, POR, PWM, WDT
Number Of I /o
46
Program Memory Size
24KB (24K x 8)
Program Memory Type
FLASH
Ram Size
2K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Data Converters
A/D 12x10b
Oscillator Type
Internal
Operating Temperature
0°C ~ 70°C
Package / Case
68-LCC (J-Lead)
Processor Series
Z8F242x
Core
eZ8
Data Bus Width
8 bit
Data Ram Size
2 KB
Interface Type
I2C, SPI, UART
Maximum Clock Frequency
20 MHz
Number Of Programmable I/os
46
Number Of Timers
4
Operating Supply Voltage
3 V to 3.6 V
Maximum Operating Temperature
+ 70 C
Mounting Style
SMD/SMT
Development Tools By Supplier
Z8F64200100KITG, ZENETSC0100ZACG, ZUSBSC00100ZACG, Z8F64210100ZDA, Z8F64210100ZDP, Z8F64210100ZDV, Z8F64220100ZDA, Z8F64220100ZDV, Z8F6422AR00ZEM, Z8F6422VS00ZEM, Z8F6421AN00ZEM
Minimum Operating Temperature
0 C
On-chip Adc
10 bit, 12 Channel
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / Rohs Status
 Details
Other names
269-4253
Z8F2422VS020SG

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
Z8F2422VS020SG
Manufacturer:
Zilog
Quantity:
10 000
PS019921-0308
Interrupt Vectors and Priority
Interrupt Assertion
Caution:
Software Interrupt Assertion
Caution:
The interrupt controller supports three levels of interrupt priority. Level 3 is the highest
priority, Level 2 is the second highest priority, and Level 1 is the lowest priority. If all of
the interrupts were enabled with identical interrupt priority (all as Level 2 interrupts, for
example), then interrupt priority would be assigned from highest to lowest as specified in
Table 23
which, in turn, always have higher priority than Level 1 interrupts. Within each interrupt
priority level (Level 1, Level 2, or Level 3), priority is assigned as specified in
page 63. Reset, Watchdog Timer interrupt (if enabled), and Illegal Instruction Trap always
have highest priority.
Interrupt sources assert their interrupt requests for only a single system clock period
(single pulse). When the interrupt request is acknowledged by the eZ8 CPU, the
corresponding bit in the Interrupt Request register is cleared until the next interrupt
occurs. Writing a 0 to the corresponding bit in the Interrupt Request register likewise
clears the interrupt request.
Program code can generate interrupts directly. Writing a 1 to the desired bit in the Interrupt
Request register triggers an interrupt (assuming that interrupt is enabled). When the inter-
rupt request is acknowledged by the eZ8 CPU, the bit in the Interrupt Request register is
automatically cleared to 0.
The following style of coding to clear bits in the Interrupt Request registers is
NOT recommended. All incoming interrupts that are received between
execution of the first LDX command and the last LDX command are lost.
the Interrupt Request 0 register is recommended:
The following style of coding to generate software interrupts by setting bits in
the Interrupt Request registers is NOT recommended. All incoming interrupts
To avoid missing interrupts, the following style of coding to clear bits in
on page 63. Level 3 interrupts always have higher priority than Level 2 interrupts
Poor coding style that can result in lost interrupt requests:
Good coding style that avoids lost interrupt requests:
LDX r0, IRQ0
AND r0, MASK
LDX IRQ0, r0
ANDX IRQ0, MASK
Z8 Encore! XP
Product Specification
®
Interrupt Controller
F64XX Series
Table 23
on
66