C8051F541-IM Silicon Laboratories Inc, C8051F541-IM Datasheet - Page 196

IC 8051 MCU 16K FLASH 32-QFN

C8051F541-IM

Manufacturer Part Number
C8051F541-IM
Description
IC 8051 MCU 16K FLASH 32-QFN
Manufacturer
Silicon Laboratories Inc
Series
C8051F54xr
Datasheets

Specifications of C8051F541-IM

Program Memory Type
FLASH
Program Memory Size
16KB (16K x 8)
Package / Case
32-QFN
Mfg Application Notes
LIN Bootloader AppNote
Core Processor
8051
Core Size
8-Bit
Speed
50MHz
Connectivity
SMBus (2-Wire/I²C), SPI, UART/USART
Peripherals
POR, PWM, Temp Sensor, WDT
Number Of I /o
25
Ram Size
1.25K x 8
Voltage - Supply (vcc/vdd)
1.8 V ~ 5.25 V
Data Converters
A/D 25x12b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 125°C
Processor Series
C8051F5x
Core
8051
Data Bus Width
8 bit
Data Ram Size
256 B
Maximum Clock Frequency
50 MHz
Number Of Programmable I/os
25
Operating Supply Voltage
1.8 V to 5.25 V
Maximum Operating Temperature
+ 125 C
Mounting Style
SMD/SMT
3rd Party Development Tools
PK51, CA51, A51, ULINK2
Development Tools By Supplier
C8051F540DK
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
336-1672 - BOARD PROTOTYPE W/C8051F540336-1669 - KIT DEVELOPMENT FOR C8051F540
Eeprom Size
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
336-1673-5
C8051F54x
196
Bit
MASTER
TXMODE
STA
STO
ACKRQ
ARBLOST
ACK
SI
Set by Hardware When:
A START is generated.
START is generated.
SMB0DAT is written before the start of an
SMBus frame.
A START followed by an address byte is
received.
A STOP is detected while addressed as a
slave.
Arbitration is lost due to a detected STOP.
A byte has been received and an ACK
response value is needed.
A repeated START is detected as a
MASTER when STA is low (unwanted
repeated START).
SCL is sensed low while attempting to
generate a STOP or repeated START
condition.
SDA is sensed low while transmitting a 1
(excluding ACK bits).
The incoming ACK value is low 
(ACKNOWLEDGE).
A START has been generated.
Lost arbitration.
A byte has been transmitted and an
ACK/NACK received.
A byte has been received.
A START or repeated START followed by a
slave address + R/W has been received.
A STOP has been received.
Table 20.3. Sources for Hardware Changes to SMB0CN
Rev. 1.1
Cleared by Hardware When:
A STOP is generated.
Arbitration is lost.
A START is detected.
Arbitration is lost.
SMB0DAT is not written before the
start of an SMBus frame.
Must be cleared by software.
A pending STOP is generated.
After each ACK cycle.
Each time SI is cleared.
The incoming ACK value is high
(NOT ACKNOWLEDGE).
Must be cleared by software.