LMP8601MA/NOPB National Semiconductor, LMP8601MA/NOPB Datasheet - Page 18

IC AMP CURRENT SENSE 60V 8SOIC

LMP8601MA/NOPB

Manufacturer Part Number
LMP8601MA/NOPB
Description
IC AMP CURRENT SENSE 60V 8SOIC
Manufacturer
National Semiconductor
Series
LMP®r
Datasheet

Specifications of LMP8601MA/NOPB

Amplifier Type
Current Sense
Number Of Circuits
1
Slew Rate
0.83 V/µs
Gain Bandwidth Product
60kHz
Current - Input Bias
0.04pA
Voltage - Input Offset
150µV
Current - Supply
1.1mA
Current - Output / Channel
48mA
Voltage - Supply, Single/dual (±)
3 V ~ 5.5 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
8-SOIC (3.9mm Width)
No. Of Amplifiers
1
Input Bias Current
20nA
Input Offset Voltage
1mV
Bandwidth
60kHz
Cmrr
90dB
Supply Voltage Range
3V To 5.5V
Supply Current
1.1mA
Rohs Compliant
Yes
Number Of Channels
1
Common Mode Rejection Ratio (min)
80 dB
Available Set Gain
26.06 dB
Operating Supply Voltage
5 V
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Supply Voltage (max)
5.5 V
Supply Voltage (min)
3 V
For Use With
LMP8601MAEVAL - BOARD EVALUATION FOR LMP8601MA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Output Type
-
-3db Bandwidth
-
Lead Free Status / Rohs Status
 Details
Other names
*LM8601MA/NOPB
LMP8601MA

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LMP8601MA/NOPB
Manufacturer:
TI
Quantity:
14 500
www.national.com
BATTERY CURRENT MONITOR APPLICATION
This application example shows how the LMP8601/LM-
P8601Q can be used to monitor the current flowing in and out
a battery pack. The fact that the LMP8601/LMP8601Q can
measure small voltages at a high offset voltage outside the
parts own supply range makes this part a very good choice
ADVANCED BATTERY CHARGER APPLICATION
The above circuit can be used to realize an advanced battery
charger that has the capability to monitor the exact net current
that flows in and out the battery as show in
output signal of the LMP8601/LMP8601Q is digitized with the
FIGURE 11. Battery Current Monitor Application
Figure
12. The
K2 = 2
18
for such applications. If the load current of the battery is higher
then the charging current, the output voltage of the LMP8601/
LMP8601Q will be above the “half offset voltage” for a net
current flowing out of the battery. When the charging current
is higher then the load current the output will be below this
“half offset voltage”.
A/D converter and used as an input for the charge controller.
The Charge controller can me used to regulate the charger
circuit to deliver exactly the current that is required by the load,
avoiding overcharging a fully loaded battery
20157154

Related parts for LMP8601MA/NOPB