ADP125ARHZ-R7 Analog Devices Inc, ADP125ARHZ-R7 Datasheet - Page 4

IC REG LDO ADJ 500MA 8MSOP

ADP125ARHZ-R7

Manufacturer Part Number
ADP125ARHZ-R7
Description
IC REG LDO ADJ 500MA 8MSOP
Manufacturer
Analog Devices Inc
Datasheets

Specifications of ADP125ARHZ-R7

Regulator Topology
Positive Adjustable
Voltage - Output
0.8 ~ 5 V
Voltage - Input
2.3 ~ 5.5 V
Voltage - Dropout (typical)
0.13V @ 500mA
Number Of Regulators
1
Current - Output
500mA (Max)
Current - Limit (min)
550mA
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
8-MSOP Exposed Pad, 8-HMSOP, 8-eMSOP
Primary Input Voltage
5.5V
Output Voltage Adjustable Range
800mV To 5V
Dropout Voltage Vdo
130mV
No. Of Pins
8
Output Current
500mA
Voltage Regulator Case Style
MSOP
Operating Temperature Range
-40°C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
ADP125ARHZ-R7TR
ADP124/ADP125
Parameter
OUTPUT NOISE
POWER SUPPLY REJECTION RATIO
1
2
3
4
5
6
RECOMMENDED CAPACITOR SPECIFICATIONS
Table 2.
Parameter
Minimum Input and Output
Capacitor ESR
1
The current from the external resistor divider network in the case of adjustable voltage output (as with the ADP125) should be subtracted from the ground current measured.
Accuracy when VOUT is connected directly to ADJ. When VOUT voltage is set by external feedback resistors, absolute accuracy in adjust mode depends on the tolerances of
the resistors used.
Based on an endpoint calculation using 1 mA and 500 mA loads.
Dropout voltage is defined as the input-to-output voltage differential when the input voltage is set to the nominal output voltage. This applies only for output voltages
greater than 2.3V.
Start-up time is defined as the time between the rising edge of EN to VOUT being at 90% of its nominal value.
Current limit threshold is defined as the current at which the output voltage drops to 90% of the specified typical value. For example, the current limit for a 3.3 V
output voltage is defined as the current that causes the output voltage to drop to 90% of 3.3V, or 2.97 V.
The minimum input and output capacitance should be greater than 0.70 μF over the full range of operating conditions. The full range of operating conditions in the
application must be considered during device selection to ensure that the minimum capacitance specification is met. X7R and X5R type capacitors are recommended;
Y5V and Z5U capacitors are not recommended for use with this LDO.
(V
Capacitance
IN
= V
OUT
+1V)
1
Symbol
OUT
PSRR
Symbol
CAP
R
ESR
MIN
NOISE
Test Conditions
10 Hz to 100 kHz, V
10 Hz to 100 kHz, V
10 Hz to 100 kHz, V
10 Hz to 100 kHz, V
10 Hz to 100 kHz, V
10 kHz to 100 kHz, V
Test Conditions
T
T
A
A
= −40°C to +125°C
= −40°C to +125°C
Rev. 0 | Page 4 of 20
IN
IN
IN
IN
IN
OUT
= 5.5 V, V
= 5.5 V, V
= 5.5 V, V
= 5.5 V, V
= 5.5 V, V
= 1.8 V, 2.5 V, 3.3 V
OUT
OUT
OUT
OUT
OUT
= 1.2 V
= 1.8 V
= 2.5 V
= 3.3 V
= 4.2V
Min
Min
0.70
0.001
Typ
25
35
45
55
65
60
Typ
Max
Max
1
Unit
μV rms
μV rms
μV rms
μV rms
μV rms
dB
Unit
μF
Ω