MF-RX012/250-0 Bourns Inc., MF-RX012/250-0 Datasheet

FUSE PTC RESETTABLE 0.12A HOLD

MF-RX012/250-0

Manufacturer Part Number
MF-RX012/250-0
Description
FUSE PTC RESETTABLE 0.12A HOLD
Manufacturer
Bourns Inc.
Series
MF-RXr
Datasheets

Specifications of MF-RX012/250-0

R Min/max
4.000 ~ 8.000 Ohm
Voltage - Max
250V
Current - Hold (ih) (max)
120mA
Current - Max
3A
Package / Case
Radial
Initial Resistance Max
8ohm
Svhc
No SVHC (15-Dec-2010)
Approval Bodies
CSA, TUV
Approval Category
UL Recognised
Current Max
3A
External Depth
4.6mm
External Length /
RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Current - Trip (it)
-
Time To Trip
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MF-RX012/250-0-U9
Manufacturer:
AUO
Quantity:
19 902
Operating/Storage Temperature ..............................-40 °C to +85 °C
Maximum Device Surface Temperature
Passive Aging ..........................................................+85 °C, 1000 hours ........................................................±15 % typical resistance change
Humidity Aging ........................................................+85 °C, 85 % R.H. 500 hours ..........................................±15 % typical resistance change
Thermal Shock ........................................................MIL-STD-202F, Method 107G, ........................................±10 % typical resistance change
Solvent Resistance ..................................................MIL-STD-202, Method 215B............................................No change
Lead Solerability ......................................................ANSI/J-STD-002 ..............................................................>95 % coverage
Flammability ............................................................IEC 695-2-2......................................................................No Flame for 60 secs.
Vibration ..................................................................MIL-STD-883C, Method 2007.1, Condition A..................±5 % typical resistance change
Test
Visual/Mech. ......................................................Verify dimensions and materials..................Per MF physical description
Resistance ..........................................................In still air @ 23 °C ........................................Rmin ≤ R ≤ R1max
Time to Trip ........................................................At specified current, Vmax, 23 °C ..............T ≤ typical time to trip (seconds)
Hold Current ......................................................30 min. at Ihold............................................No trip
Trip Cycle Life ....................................................Vmax, Imax, 100 cycles ..............................No arcing or burning
Trip Endurance....................................................Vmax, 48 hours ..........................................No arcing or burning
UL File Number ..................................................E 174545S
CSA File Number ................................................CA 110338
TÜV File Number ................................................R02057213
“U” suffix indicates product without insulation coating.
MF-RX012/250
MF-RX012/250-A
MF-RX012/250-C
MF-RX012/250-F
MF-RX012/250-1
MF-RX012/250-2
MF-RX012/250-T
MF-RX012/250U
MF-RX014/250
MF-RX014/250-A
MF-RX014/250-B
MF-RX014/250-T
MF-RX014/250U
MF-RX018/250
MF-RX018/250U
Electrical Characteristics
in Tripped State......................................................125 °C
Environmental Characteristics
Test Procedures And Requirements For Model MF-RX/250 Series
Model
Operating
Voltage
(Vdc)
Max.
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
Test Conditions
+60°C, 1000 hours
+125 °C to -55 °C,10 times
MF-RX/250 Series -
Features
Radial Leaded Devices
Fast tripping resettable PTCs
Binned and sorted narrow resistance
ranges available
RoHS compliant*
Lead free
Agency recognition:
(Vrms)
Volts
Max.
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
Interrupt
Ratings
Max.
Amps
Max.
10.0
10.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
(A)
Customers should verify actual device performance in their specific applications.
T V Rheinland
Telecom PTC Resettable Fuses
Current
Amps
0.145
0.145
0.145
0.145
0.145
23 °C
Hold
0.12
0.12
0.12
0.12
0.12
0.12
0.12
0.12
0.18
0.18
I H
at
Accept/Reject Criteria
Applications
±15 % typical resistance change
±15 % typical resistance change
*
Customer Premise Equipment (CPE)
Central Office / Telecom Centers (CO)
Access equipment
RoHS Directive 2002/95/EC Jan 27 2003 including Annex
Specifications are subject to change without notice.
Ohms
23 °C
Min.
4.0
7.0
5.5
6.0
6.0
8.0
7.0
6.0
3.0
3.0
4.5
5.4
3.5
0.8
0.8
at
Resistance
Initial
Ohms
23 °C
Max.
10.5
10.5
12.0
10.0
8.0
9.0
7.5
9.0
6.0
5.5
6.0
7.5
6.5
2.0
2.0
at
Resistance
One Hour
Post-Trip
Ohms
23 °C
Max.
16.0
16.0
14.0
16.0
16.0
16.0
16.0
16.0
14.0
12.0
14.0
14.0
12.0
4.0
4.0
at

Related parts for MF-RX012/250-0

MF-RX012/250-0 Summary of contents

Page 1

... Lead Solerability ......................................................ANSI/J-STD-002 ..............................................................>95 % coverage Flammability ............................................................IEC 695-2-2......................................................................No Flame for 60 secs. Vibration ..................................................................MIL-STD-883C, Method 2007.1, Condition A..................±5 % typical resistance change Test Procedures And Requirements For Model MF-RX/250 Series Test Visual/Mech. ......................................................Verify dimensions and materials..................Per MF physical description Resistance ..........................................................In still air @ 23 °C ........................................Rmin ≤ R ≤ R1max Time to Trip ........................................................At specified current, Vmax, 23 ° ...

Page 2

... Additional Features Ability to withstand AC power cross conditions Assists equipment with meeting ITU-T K.20/K.21/K.45 Assists equipment with meeting Telcordia GR-1089-C Intrabuilding MF-RX/250 Series - Thermal Derating Chart - I hold (Amps) Model -40 °C -20°C MF-RX012/250 0.186 0.165 MF-RX014/250 0.225 0.199 MF-RX018/250 0.269 0.240 I trip is approximately two times I hold. ...

Page 3

... MF-RX/250 Series - How to Order 012/250 Multifuse ® Product Designator Series RX = Radial Leaded Component Hold Current, Ihold 008-018 (0.08-0.18 Amps) Max. Interrupt Voltage, V 250 (250 Volts) Telecom Options U = Uncoated (radial parts only) Resistance Sorted Narrow resistance ranges - see Resistance Options chart Resistance Bins of 0.5 ohms ...

Page 4

... MF-R, MF-R/90, MF-R/600, MF-RX, MF-RX/72 & MF-RX/250 Series Tape and Reel Specifications Devices taped using EIA468–B/IEC286-2 standards. See table below and Figures 1 and 2 for details. Dimension Description Carrier tape width Hold down tape width: Hold down tape Top distance between tape edges ...

Page 5

... MF-R, MF-R/90, MF-R/600, MF-RX, MF-RX/72 & MF-RX/250 Series Tape and Reel Specifications Dimension Description Arbor hole diameter Core diameter: MF-R, MF-RX, MF-R/90 Core diameter: MF-RX/250, MF-R/600 Box: MF-R, MF-RX, MF-R/90 Box: MF-RX/250 Box: MF-R/600 Consecutive missing places: MF-R, MF-RX, MF-R/90 Consecutive missing places: MF-RX/250, MF-R/600 ...

Related keywords