E3X-NA6 Omron, E3X-NA6 Datasheet

no-image

E3X-NA6

Manufacturer Part Number
E3X-NA6
Description
CONN READY NPN GEN PURPOSE FO
Manufacturer
Omron
Series
E3X-NAr
Datasheets

Specifications of E3X-NA6

Amplifier Type
Wire Saving
Voltage - Supply
12 V ~ 24 V
Output Type
NPN
Current - Supply
35mA
Mounting Type
DIN Rail
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
E3XNA6
E3XNA6Q
Solve Your Basic Sensing Challenges
Easily with the E3X-NA Series
I
I
I
I
I
I
I
I
I
Ordering Information:
Amplifier Units, Connectors, Accessories and Fiber-Optics
I
Type
Standard
High-speed
Mark-detection
Water-resistant
Streamlined features provide basic sensing
immediately after plug-in
Wire-saving amplifiers reduce installation
time and minimize space requirements
Master/slave connector design affords
connectivity for up to 16 wire-saving
amplifiers
Use the LED bar display to quickly confirm
sensor performance
Optical communication design prevents
mutual interference for up to 5 amplifiers
Green LED models address mark-detecting
applications
High-speed models have a response time
of 50 µs
Select a water-resistant model (IP66 rating)
using an M8 connector
Prewired water-resistant models are available
Amplifier Units with Cables
User-Friendly Fiber-Optic Amplifier
Part number
NPN output
E3X-NA11
E3X-NA11F
E3X-NAG11
E3X-NA11V
PNP output
E3X-NA41
E3X-NA41F
E3X-NAG41
E3X-NA41V
Control output
ON/OFF
Appearance
E3X-NA

Related parts for E3X-NA6

E3X-NA6 Summary of contents

Page 1

... User-Friendly Fiber-Optic Amplifier Solve Your Basic Sensing Challenges Easily with the E3X-NA Series I Streamlined features provide basic sensing immediately after plug-in I Wire-saving amplifiers reduce installation time and minimize space requirements I Master/slave connector design affords connectivity for wire-saving amplifiers I Use the LED bar display to quickly confirm ...

Page 2

... Master E3X-CN11 Slave E3X-CN12 XS3F-M421-40 XS3F-M422-40 Cable length 2 m Applicable Connectors (Order Separately) NPN PNP Master Connector + E3X-NA6 E3X-NA8 E3X-CN11 (3-wire Master Connector + 4 Slave Connectors Cable type Fiber-Optic Cables I The E3X-NA amplifiers use Omron’s E32-series fiber-optic cables. With a choice of over 80 sensing heads, you are sure to find one that matches your application requirements ...

Page 3

... Protective Cover attached) Approx. 110 g Polyethersulfone (PES) E3X-CN12 Approx E3X-NA Connector-ready amplifier units Wire-saving Water-resistant models models (use M8 connectors) E3X-NA6 E3X-NA14V E3X-NA8 E3X-NA44V 500 VAC at 50 for 1 minute IEC60529 IEC60529 IP66 IP50 (with (with Protective Protective Cover attached) Cover at- tached) ...

Page 4

... Timer Switch ON: Timer function is ON. OFF: Timer function is OFF. LED Bar Display I Indicators In addition to an operation indicator (orange), the E3X-NA also has incident level indicators (4 green and 1 red). Use these indicators for optical axis adjustments and maintenance. Status of indicators Operation (in L/ON mode) ...

Page 5

... E3X-NA Operation Output Circuits I Output Model Mode Timing chart selector NPN E3X-NA11 LIGHT Incident light E3X-NA6 ON No incident light E3X-NAG11 (L/ON) Operation indicator E3X-NA11F (orange) E3X-NA11V Output E3X-NA14V transistor Load (relay) DARK Incident light ON No incident light (D/ON) Operation indicator (orange) ...

Page 6

... Distance X (mm) −40 −60 E3X-NA@ (V) E3X-NA@F −80 E32-D11L 150 X 100 E3X-NAG 300 400 500 Distance X (mm) 200 100 −50 E3X-NA@F −100 E3X-NA@ (V) −150 E32-D33 E3X-NA Distance X (mm) −5 E3X-NA@ (V) −10 −15 E3X-NA E32-T11R 200 X 150 Y E3X-NAG@ 100 ...

Page 7

... E3X-NA Number of turn ns Sensing Distance vs. Hysteresis E32-T11L 100 80 60 E3X-NA@ ( 100 200 300 400 500 600 700 0 Distance (mm Distance (mm) E32-D11L 400 300 E3X-NA@ (V) 200 100 @ Number of t Number of turns E32-D11L 20 15 E3X-NA@ ( 100 150 200 0 Distance Distance (mm) E3X-NA 7 ...

Page 8

... With these models, a 4-dia., 3-conductor, vinyl-insulated round cable (conductor cross-sectional area: 0.45 mm diameter: 1.1 mm) is used. Standard length The hole for optical communications is for preventing mutual interference. There is no hole for E3X-NA@F models. Water-Resistant Amplifier Units with Cables (with Mounting Bracket Attached) ...

Page 9

... E3X-NA Wire-Saving Amplifiers E3X-NA6 E3X-NA8 10 (0.39) Two, 2.4 dia. 8 10.7 Dimensions with Master Connector Connected 71 (2.80) 67.5 64.3 31.5 (1.24) 1.5 1.8 5.1 3.9 M8 Connector-Ready, Water-Resistant Amplifier Units E3X-NA14V E3X-NA44V Two, 2.4 dia. 33 (1.30) 8 10.7 3.9 Mounting Holes Two Incident level indicators Operation indicator 13 ...

Page 10

... See note. 4 8.4 15 (6.56 ft.) 10.7 6.8 See note. 4 8.4 15.1 2. dia. 12 dia 21.5 3.4 31 23.1 4 dia. 9 dia. 3.4 0.5 1.95 E3X-NA 4 dia. 30± 10± insulation diameter: 1.1 mm) is used. 2.6 dia. 30± 10± insulation diameter: 1.1 mm) is used ...

Page 11

... E3X-NA Accessories (Order Separately Mounting Bracket for E3X-NA , E3X-NA E39-L143 10.3 5.3 Material: Stainless steel (SUS 304) @ Mounting Bracket for E3X-NA V Models E39-L148 12 max. 12 Material: Stainless steel (SUS 304) End Plate PFP-M 4 and E3X-NAG Models 34.8 (1.37 7.3 26.8 Two, 3.2 dia. ...

Page 12

... E3X-NA may burst or burn. Polarity When supplying power to the E3X-NA, make sure that the polarity of the power is correct, or the E3X-NA may burst or burn. No-load Operation A load must be connected to the E3X-NA during operation, or internal elements may burst or burn. Always wire through a load. ...

Page 13

... The ratings and performance specifications for items such as the minimum sensing target and characteristics are based on prod- ucts taken at random from certain production lots. Use this data as reference only. Protective Cover Be sure to mount the Protective Cover before use. (2) E3X-NA (4) DIN rail (3) Plain washers (6-mm dia. max.) 13 ...

Page 14

... N·m max. E32-T16WR Use a proper-sized wrench. Fiber Connection and Disconnection The E3X-NA Amplifier Unit has a lock button. Connect or discon- nect the fibers to or from the E3X-NA Amplifier Unit using the following procedures: 1. Connection Open the protective cover, insert the fibers according to the fiber insertion marks on the side of the Amplifier Unit, and lower the lock button ...

Page 15

... After the Amplifier Unit has been separated, press down on the lever on the Connector and remove it. (Do not attempt to remove Connectors without separating them from other Amplifier Units first not bend here. E3X-NA Insert Sticker Sticker Press down Lever Remove ...

Page 16

... Insert the clip that removed into the slit underneath the clip on another Amplifier Unit. 2. Remove the clip by rotating the Amplifier Unit. Rotate Pull Strengths for Connectors (Including Cables) E3X-CN11 max. E3X-CN12 max. 16 Reflector I Use of E39-R3 Reflector Use detergent, etc., to remove any dust or oil from the surfaces where tape is applied ...

Page 17

... E3X-NAG@ 40 E3X-NA@F 60 E3X-NA@ (V) 200 E3X-NAG@ 40 E3X-NA@F 60 E3X-NA@ (V) E3X-NA@F E3X-NA@ (V) 400 (3,000) E3X-NAG@ 75 (550) E3X-NA@F 120 (900) E3X-NA@ (V) 360 E3X-NAG@ 65 E3X-NA@F 100 E3X-NA@ (V) 100 E3X-NAG@ 20 E3X-NA@F 30 E3X-NA@ (V) 100 E3X-NAG@ 20 E3X-NA@F 30 E3X-NA@ (V) 400 E3X-NAG@ 75 1.2-mm dia. E3X-NA@F 120 E3X-NA@ (V) 100 E3X-NAG@ 20 0.9-mm dia. ...

Page 18

... E3X-NA@F 0.5-mm dia. 30 (0.1-mm dia.) E3X-NA@ (V) 1.0-mm dia. 280 (2,100) (0.03-mm dia.) E3X-NAG@ 50 (375) E3X-NA@F 1.0-mm dia. 80 (600) (0.2-mm dia.) E3X-NA@ (V) 1.0-mm dia. 280 (2,100) (0.03-mm dia.) E3X-NAG@ 50 (375) E3X-NA@F 1.0-mm dia. 80 (600) (0.2-mm dia.) E3X-NA@ (V) 0.5-mm dia. 60 (0.03-mm dia.) E3X-NAG@ ...

Page 19

... E3X-NA@F 1.5-mm dia. 120 (1.0-mm dia.) E3X-NA@ (V) 1.0-mm dia. 300 (3,000) (0.03-mm dia.) E3X-NA@F 1.0-mm dia. 90 (0.5-mm dia.) E3X-NA@ (V) 1.0-mm dia. (0.03-mm dia.) 130 E3X-NA@F 1.0-mm dia. (0.3-mm dia.) 35 E3X-NA@ (V) 1.7-mm dia. 700 (0.03-mm dia.) E3X-NA@F 1.7-mm dia. ...

Page 20

... The values of the minimum sensing target for E3X-NA@ (V) and E3X-NAG@ through-beam models indicate those obtained where the sensing distance and sensitivity are set to optimum values. 3. The value of the minimum sensing target for E3X-NA@F through-beam models indicates that obtained at the rated sensing dis- tance with the sensitivity set to the optimum value. ...

Page 21

... E3X-NA@ (V) 150 E3X-NAG screw E3X-NA@F 50 E3X-NA@ (V) 36 E3X-NAG screw E3X-NA@F 12 E3X-NA@ (V) 150 E3X-NAG@ 25 2.5-mm dia. E3X-NA@F 50 E3X-NA@ (V) 36 E3X-NAG@ 6 1.2-mm dia. E3X-NA@F 12 E3X-NA@ (V) 10 E3X-NA@F 0.8-mm dia. 3.3 E3X-NA@ 1.5 0.5-mm dia. E3X-NA@F 0.5 E3X-NA Standard object Part Permis- (see note) (min. ...

Page 22

... M3 screw E3X-NA@F 5 E3X-NA@ (V) 15 E3X-NAG@ 2.4 M4 screw E3X-NA@F 5 E3X-NA@ (V) 7 1.5-mm dia. E3X-NA@F 2.3 E3X-NA@ (V) 90 E3X-NAG screw E3X-NA@F 30 E3X-NA@ (V) 90 E3X-NAG@ 15 3-mm dia. E3X-NA@F 30 E3X-NA@ ( screw E3X-NA@F 5 E3X-NA@ (V) 15 3-mm dia. E3X-NA@F 5 E3X-NA Standard object Part Permis- (see note) (min. ...

Page 23

... E3X-NAG screw E3X-NA@F 50 E3X-NA@ (V) 80 E3X-NAG@ 12 3-mm dia. E3X-NA@F 25 E3X-NA@ (V) 40 E3X-NAG screw E3X-NA@F 13 E3X-NA@ ( screw E3X-NA@F 5 E3X-NA@ (V) 15 2-mm dia. E3X-NA@F 5 E3X-NA@ (V) 40 E3X-NAG@ 6 2-mm dia. E3X-NA@F 13 E3X-NA@ (V) 40 E3X-NAG@ 10 E3X-NA@F 13 E3X-NA@ (V) 16 E3X-NA@F 5 E3X-NA@ (V) 15 2-mm dia. E3X-NAG@ 2 ...

Page 24

... E3X-NA@F 4±2 E3X-NA@ (V) 7.2±1.8 E3X-NA@F 7.2±1.8 E3X-NA@ (V) 3.3 E3X-NA@F 3.3 E3X-NA@ (V) 3.3 E3X-NA@F 3.3 E3X-NA@ (V) --- E3X-NA@F E3X-NA@ (V) --- E3X-NA@F ° 130 E3X-NA Standard object Part Permis- (see note) (min. number sible sensing target: bending Gold wire) radius 150×150 35 mm E32-D51 (0 ...

Page 25

... E3X-NA E3X-NA 25 ...

Page 26

... E3X-NA 26 E3X-NA ...

Page 27

... E3X-NA E3X-NA 27 ...

Page 28

... OMRON ELECTRONICS LLC One East Commerce Drive Schaumburg, IL 60173 1-800-55-OMRON Cat. No. E318-E3-1 10/01/7.5M 28 OMRON ON-LINE Global - http://www.omron.com USA - http://www.omron.com/oei Canada - http://www.omron.com/oci Specifications subject to change without notice E3X-NA OMRON CANADA, INC. 885 Milner Avenue Scarborough, Ontario M1B 5V8 416-286-6465 Printed in USA ...

Related keywords