Specifications of E3X-NA6

Amplifier Type
Wire Saving
Voltage - Supply
12 V ~ 24 V
Output Type
NPN
Current - Supply
35mA
Mounting Type
DIN Rail
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
E3XNA6
E3XNA6Q
E3X-NA
I
Joining Amplifier Units
1.
2. Line up the clips and slide the Amplifier Units together. Then
Separating Amplifier Units
Slide Amplifier Units away from each other, and remove from the
DIN rail one at a time. (Do not attempt to remove Amplifier Units
from the DIN rail without separating them first.)
Note:
Mounting
1.
2. Press the back part onto the mounting bracket or the DIN rail.
Note:
Mounting the Amplifier Unit
press the Amplifier Units together until they click into place.
E39-L148 (order separately) or onto a DIN rail.
Mount the Amplifier Units one at a time onto the DIN rail.
Mount the front part on the mounting bracket E39-L143 or
1. The specifications for ambient temperature will vary
2. Always turn OFF the power supply before joining or
Do not mount the back of the Amplifier Unit onto the
mounting bracket or the DIN rail first, or the mounting
strength of the Amplifier Unit may be reduced. Always
mount the front of the Amplifier Unit first.
according to the number of Amplifier Units used
together. For details, refer to Ratings/Characteristics in
the Specifications section of this data sheet.
separating Amplifier Units.
Clip
(1)
DIN rail
Click into
place
(2)
Removal
Pull the lock tab of the Amplifier Unit with a flat blade screwdriver
in direction (3) and lift the fiber insertion part in direction (4) as
shown below.
When side-mounting using a mounting bracket, secure the
mounting bracket to the Amplifier Unit and then mount using M3
screws. Use plain washers of diameter 6mm or less when
mounting.
Operating Environment
Ambient Conditions
Dust or dirt accumulation on the optical communications hole may
prevent normal communications. Be sure to remove any dust or
dirt before using the Unit.
Ratings and Specifications
The ratings and performance specifications for items such as the
minimum sensing target and characteristics are based on prod-
ucts taken at random from certain production lots. Use this data
as reference only.
Protective Cover
Be sure to mount the Protective Cover before use.
(4)
Plain washers
(6-mm dia. max.)
DIN rail
(3)
E3X-NA