2866983 Phoenix Contact, 2866983 Datasheet
![POWER SUPPLY 1.5A 24VDC](/photos/13/96/139650/mfg_2866983_sml.jpg)
2866983
Specifications of 2866983
MINI-SYS-PS-100-240AC/24DC/1.5
Related parts for 2866983
2866983 Summary of contents
Page 1
... Make sure you always use the the latest documentation. It can be downloaded at www.download.phoenixcontact.com. A conversion table is available on the Internet at www.download.phoenixcontact.com/general/7000_en_00.pdf. © PHOENIX CONTACT - 11/2006 The electronic short circuit and idling-proof device is con- nected to single-phase AC networks with nominal voltages of 100 240 two of the phase conductors of three-phase networks with a linked voltage of this value ...
Page 2
... Peak switching voltages Connection in parallel Surge protection against internal surge voltages Resistance to reverse feed 102050_01_en MINI-SYS-PS-100-240AC/24DC/1.5 Type Order No. MINI-SYS-PS-100-240AC/24DC/1.5 2866983 Type Order No. ME 17,5 TBUS 1,5/ 5-ST-3,81 GN 2709561 100 V AC ... 240 ... 264 ... 65 Hz Approx. 0.75 A (120 V AC) Approx. 0.45 A (230 V AC) 2 < ...
Page 3
... IEC 61709 (SN 29500) Polyamide PA, color: green 0.25 kg -25 °C ... 70 °C (> 60°C derating) -40 °C ... 85 ° (at 25°C, no condensation) < 15 Hz, amplitude ±2 acc. with IEC 60068-2 ... 150 Hz, 2.3g, 90 min. 30g in all directions in acc. with IEC 60068-2-27 2 3K3 (in acc. with EN 60721) 3 PHOENIX CONTACT ...
Page 4
... Comments Criterion B Input/Output/Signal Level 3 - asymmetrical Frequency range 0.15 MHz ... 80 MHz Voltage 10 V Comments Criterion A Input (mains buffering > 20 ms) Comments Criterion B EN 55011 (EN 55022) Class B, area of application: Industry and residential EN 55011 (EN 55022) Class B, area of application: Industry and residential MINI-SYS-PS-100-240AC/24DC/1.5 PHOENIX CONTACT 4 ...
Page 5
... A (power circuit-breaker, characteristic B) COMBICON screw/plug connection ±1% 1.5 A (up to 60° (with POWER BOOST) COMBICON screw/plug connection 7 mm MINI-SYS-PS-100-240AC/24DC/1.5 2 [mm ] AWG [Nm] solid stranded Torque 0.2 - 2.5 0 0.5 - 0.6 0.2 - 2.5 0 0.5 - 0.6 0.2 - 2.5 0 0.5 - 0.6 PHOENIX CONTACT 5 ...
Page 6
... In order to guarantee sufficient convection, we recommend observing the following minimum distance to other modules vertical di- rection and horizontal direction. The power supply unit can be snapped onto all DIN rails in acc. with EN 60715. They must be horizontal (connecting terminal blocks above and below). PHOENIX CONTACT 6 ...
Page 7
... Position the module with the DIN rail guide on the upper edge of the DIN rail, and snap it in with a downward moti1on. Dismantling Pull the snap lever open with the aid of a screwdriver and slide the module out at the lower edge of the DIN rail. MINI-SYS-PS-100-240AC/24DC/1.5 PHOENIX CONTACT 7 ...
Page 8
... Power circuit-breaker characteristic B (or identical function). MINI-SYS-PS-100-240AC/24DC/1 MINI For operation on two of the phase conductors of a three-phase system, an isolating facility for all poles must be provided internal fuse is triggered, there is most probably a malfunction in the device. In this case, the device must be inspected in the factory! PHOENIX CONTACT ...
Page 9
... State 2 OFF Open 1. The output voltage is less than 21.5 V. There is a secondary consumer short circuit or overload. 2. There is no input voltage or there is a device fault. PHOENIX CONTACT 9 ...
Page 10
... Kelvin increase in temperature. The de- vice does not switch off at ambient temperatures of +70°C or thermal overload. The output capacity is reduced as far as necessary to provide device protection. After it has cooled down, the output capacity is increased again. 60 MINI-SYS-PS-100-240AC/24DC/1 the case of ambi- N PHOENIX CONTACT 10 ...
Page 11
... N + − + − + PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany 102050_01_en Parallel operation Due to the current carrying capacity, a maximum of two de- vices may be connected in parallel on the DIN rail connector for redundancy. Without using the DIN rail connector, de- vices of the same type can be connected in parallel both for redundancy reasons as well as to improve performance ...