2866983 Phoenix Contact, 2866983 Datasheet - Page 8

POWER SUPPLY 1.5A 24VDC

2866983

Manufacturer Part Number
2866983
Description
POWER SUPPLY 1.5A 24VDC
Manufacturer
Phoenix Contact
Series
Minir
Type
Industrialr
Datasheets

Specifications of 2866983

Voltage - Output
24V
Number Of Outputs
1
Power (watts)
36W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
100 ~ 240VAC
Mounting Type
DIN Rail
1st Output
24 VDC @ 1.5A
Size / Dimension
3.74" L x 1.38" W x 3.90" H (95mm x 35mm x 99mm)
Operating Temperature
-25°C ~ 70°C
Power (watts) - Rated
36W
Efficiency
84%
Approvals
cUL, EN, UL, VDE
Product
Switching
Commercial/medical
Commercial
Output Power Rating
36 W
Input Voltage
100 VAC to 240 VAC
Output Voltage (channel 1)
24 VDC
Output Current (channel 1)
1.5 A
Mounting Style
DIN Rail
Interface
Ethernet Modem
Phoenix Part Number
MINI-SYS-PS-100-240AC/24DC/1.5
Standards
TBR21, TIA-968-A, CS-03 for Europe, USA, and Canada
Voltage, Supply
85-264 VAC
Configuration
Enclosed
Operation
Switching
Output
24 VDC @ 1.5 A
Power, Output
6.5 W
Primary Type
AC-DC
Voltage, Input
85 to 264 VAC
Voltage, Output
24 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
277-2136
MINI-SYS-PS-100-240AC/24DC/1.5
102050_01_en
Connection, network forms 100...240 V AC networks
The 100...240 V AC connection is made using the L and N
screw connections.
The device can be connected to 1-phase AC systems or to
two of the phase conductors of three-phase systems (TN, TT
or IT networks in acc. with VDE 0100-300/IEC 60364-3) with
nominal voltages of 100 V AC ...240 V AC.
Input
MINI
L N
TN-S
1
+
-
L
N
PE
L N
MINI
TN-C
+
-
L
PEN
Protection of the primary side
The device must be installed in acc. with the regulations as
in EN 60950. It must be possible to disconnect the device
using a suitable isolating facility outside the power supply.
The primary side line protection, for example, is suitable. For
device protection, there is an internal fuse. Additional device
protection is not necessary.
Recommended backup fuse for mains protection
Power circuit-breaker 6 A, 10 A or 16 A, characteristic B (or
identical function).
L N
MINI
TT
For operation on two of the phase conductors
of a three-phase system, an isolating facility for
all poles must be provided.
If an internal fuse is triggered, there is most
probably a malfunction in the device. In this
case, the device must be inspected in the
factory!
+
MINI-SYS-PS-100-240AC/24DC/1.5
-
L
N
MINI
L N
PHOENIX CONTACT
iT
+
-
L1
L2
L3
8