STEVAL-IFS013V2 STMicroelectronics, STEVAL-IFS013V2 Datasheet - Page 10

no-image

STEVAL-IFS013V2

Manufacturer Part Number
STEVAL-IFS013V2
Description
ZIGBEE USB DONGLE EVAL KIT
Manufacturer
STMicroelectronics
Type
Transceiver, ZigBeer
Datasheets

Specifications of STEVAL-IFS013V2

Frequency
2.4GHz
For Use With/related Products
STM32, SPZB260-PRO
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
497-10371
Software equipment of the evaluation kit
Note:
4.3.1
4.3.2
4.3.3
10/18
ready message (SINK_READY) and, at that point, the sensor is free to send data (DATA) to
the sink at fixed intervals (as set by SEND_DATA_RATE).
The sink, sensor applications require the user interaction through the serial communication
channels (virtual COM through USB). Press the “?” key on the hyper terminal for printing the
user help menu. See the
a description of the available serial commands.
Sensor
A device that takes data readings from some input source and passes these readings to
a particular collection point. Many sensors report to a single sink. When the sensor
application joins the network, led LD2 on the board will blink (visual signal that the node is
active and joined to a network).
Sink
Sink is a device that serves as a collection point for 1 or more sensor devices. In this
example, the sink is set up to be the ZigBee coordinator device, and it forms the network
automatically on first startup and retains these settings across reboots. Once the sink
application starts running, led LD2 on your evaluation STEVAL-IFS013V2 board will blink
(visual signal that the node is active).
Table 1.
Table 2.
Serial commands supported on sensor and sink
Command
Command
m
&
?
5
6
a
c
k
l
!
i
*
f
Tells the node to send a multicast hello packet
Leave the ZigBee network so on node reset the sink can form a new network
Prints info about this node including channel and power
Prints the help menu
Simulate button B1 press - turns permit join, allowing other nodes to join to this node
Leave the ZigBee network
Prints the address table
Prints the multicast table
Print child table
Print the security keys
Force the sink to advertise
Switch the network key: send the key followed by a switch key command 30 s later
Send a switch key command. This is needed only if the device sent a new key and then
reset before it was able to send the switch key command
Serial commands supported on sensor and sink
Serial commands supported on sink only
Section 4.3.3: Serial commands supported on sensor and sink
Doc ID 15114 Rev 2
Response / description
Response / description
UM0602
for