... XBee-PRO® XSC RF Module XBee-PRO® XSC RF Module RF Module Operation RF Module Configuration Appendices Product Manual 90000938-B For RF Module Part Number: XBP09-XC … 900 MHz OEM RF Modules by Digi International Inc. 11001 Bren Road East Minnetonka, MN 55343 www.digi.com 90000938_B 3, 17, 2010 ...
Page 2
... XBee‐PRO®XSC RF Module ‐ Product Manual © 2010 Digi International, Inc. All rights reserved No part of the contents of this manual may be transmitted or reproduced in any form or by any means without the written permission of Digi International, Inc. ...
Page 3
XBee‐PRO® XSC OEM RF Modules Contents 1. XBee-PRO® XSC OEM RF Module.......... 4 Key Features......................................... 5 Worldwide Acceptance .......................... 5 Specifications ....................................... 6 Pin Signals............................................ 7 Electrical Characteristics ...................... 8 Timing Specifications ............................ 8 Mechanical Drawings ............................ Module Operation ......................... 10 ...
Page 4
XBee‐PRO® XSC OEM RF Modules 1. XBee‐PRO® XSC OEM RF Module The XBee-PRO XSC (900 MHz) OEM RF Modules were engineered to afford OEMs and integrators an easy-to-use RF solution that provides reliable delivery of critical data between remote devices. These modules come configured to sustain reliable long-range wireless ...
Page 5
XBee‐PRO® XSC OEM RF Modules 1.1. Key Features Long Range Data Integrity XBee-PRO XSC (900 MHz) Range: • Indoor/Urban 1200' (370m) • Outdoor line-of-sight miles (9.6 km) w/ 2.1 dBm dipole antenna • Outdoor line-of-sight miles ...
Page 6
XBee‐PRO® XSC OEM RF Modules 1.2. Specifications Table 1‐01. XBee‐PRO XSC OEM RF Module Specifications Specification Performance Indoor/Urban Range Outdoor line-of-sight Range Interface Data Rate Throughput Data Rate RF Data Rate Transmit Power Output Receiver Sensitivity Power Requirements Supply Voltage Receive Current Transmit Current Power Down Current General Frequency Range ...
Page 7
XBee‐PRO® XSC OEM RF Modules 1.3. Pin Signals Figure 1‐01. XBee‐PRO XSC OEM RF Module Pin Numbers (top view, shield underneath) Table 1‐02. J1 Pin Signal Descriptions Module Pin © 2010 Digi International, Inc. (Low‐asserted signals distinguished with a horizontal line over signal name.) Public Signal Notes I/O VCC I DO (Data Out) O ...
Page 8
XBee‐PRO® XSC OEM RF Modules Module Pin 19 20 1.4. Electrical Characteristics Figure 1‐02. System Block Diagram The data flow sequence is initiated when the first byte of data is received in the DI Buffer of the transmitting module (XBee Module A). As long as XBee Module ...
Page 9
XBee‐PRO® XSC OEM RF Modules Table 1‐03. AC Characteristics (SY parameter = 0, symbols correspond to Figure 1‐02 and Figure 1‐03.) Symbol Description Latency from the time data transmitted until received Time that TX/PWR pin driven low Time that RX LED pin driven high T Channel Initialization Time ST ...
Page 10
XBee‐PRO® XSC OEM RF Modules 2. RF Module Operation 2.1. Serial Communications The XBee module interfaces to a host device through a CMOS-level asynchronous serial port. Through its serial port, the module can communicate with any UART voltage compatible device or through a level translator to any ...
Page 11
XBee‐PRO® XSC OEM RF Modules 2.1.3. Flow Control Figure 2‐03. Internal Data Flow Diagram (The five most commonly‐used pin signals shown.) DI (Data In) Buffer and Flow Control When serial data enters the XBee module through the DI Pin, then the data is stored in the DI Buffer until it can be transmitted. When the ...
Page 12
XBee‐PRO® XSC OEM RF Modules 2.2. Modes of Operation XBee-PRO® XSC RF Modules operate in five modes. Figure 2‐04. Modes of Operation 2.2.1. Idle Mode When not receiving or transmitting data, the RF module is in Idle Mode. The module shifts into the other modes of operation ...
Page 13
XBee‐PRO® XSC OEM RF Modules RF Packet Figure 2‐06. RF Packet Components * When streaming multiple RF packets, the RF Initializer is only sent in front of the first packet. RF Initializer An RF initializer is sent each time a new connection sequence begins. The RF initializer ...
Page 14
XBee‐PRO® XSC OEM RF Modules 2.2.3. Receive Mode If a module detects RF data while operating in Idle Mode, the module transitions into Receive Mode to start receiving RF packets. Figure 2‐08. Reception of RF Data After a packet is received, the module checks the CRC (cyclic redundancy ...
Page 15
XBee‐PRO® XSC OEM RF Modules Once in Pin Sleep Mode, CTS is de-asserted (high), indicating that data should not be sent to the module. The PWR pin is also de-asserted (low) when the module is in Pin Sleep Mode. Note: The module will complete ...
Page 16
XBee‐PRO® XSC OEM RF Modules Length of wake‐up initializer is shorter than the time interval of Cyclic Sleep. This configuration is vulnerable to the receiver waking and missing the wake‐up initializer (and therefore also the accompanying payload data). © 2010 Digi International, Inc. 16 ...
Page 17
XBee‐PRO® XSC OEM RF Modules 2.2.5. Command Mode To modify or read module parameters, the module must first enter into Command Mode, the state iin which received characters on the UARTare interpreted as commands. Two command types are avail- able for programming the module: ...
Page 18
XBee‐PRO® XSC OEM RF Modules Binary Commands Sending and receiving parameter values using binary commands is the fastest way to change operating parameters of the module. Binary commands are used most often to sample signal strength (RS parameter) and/or error counts change ...
Page 19
XBee‐PRO® XSC OEM RF Modules 3. RF Module Configuration 3.1. XBee Programming Examples For information about entering and exiting AT and Binary Command Modes, refer to the Command Mode section. 3.1.1. AT Commands To Send AT Commands (Using the ‘Terminal’ tab of the X-CTU Software) Example: Utilize ...
Page 20
XBee‐PRO® XSC OEM RF Modules 3.2. Command Reference Table Table 3‐01. AT Commands (The RF Module expects numerical values in hexadecimal. ʺdʺ denotes decimal equivalent.) AT Binary AT Command Name Command Command AT 0x05 (5d) Guard Time After BD 0x15 (21d) Interface Data Rate BT 0x04 (4d) Guard Time Before CC 0x13 (19d) Command Sequence Character CD 0x28 ...
Page 21
XBee‐PRO® XSC OEM RF Modules 3.3. Command Descriptions Commands in this section are listed alphabetically. Command categories are designated between the “< >” symbols that follow each command title. Modules expect numerical values in hexadecimal and those values are designated by a “0x” prefix. ...
Page 22
XBee‐PRO® XSC OEM RF Modules Table 3‐02. Parameter Sent vs. Parameter Stored BD Parameter Sent (HEX) BT (Guard Time Before) Command Command Summary AT Command: ATBT Binary Command: 0x04 (4 decimal) Parameter Range:2 – 0xFFFF [x 100 milliseconds] Default Parameter Value: 0x0A (10 decimal) Number of bytes returned: 2 ...
Page 23
XBee‐PRO® XSC OEM RF Modules CN (Exit AT Command Mode) Command Command Summary AT Command: ATCN Binary Command: 0x09 (9 decimal) CS (DO2 Configuration) Command Command Summary AT Command: ATCS Binary Command: 0x1F (31 decimal) Parameter Range:0 – 4 Parameter Configuration Value 0 RS-232 ...
Page 24
XBee‐PRO® XSC OEM RF Modules DT (Destination Address) Command Command Summary AT Command: ATDT Binary Command: 0x00 Parameter Range:0 – 0xFFFF Default Parameter Value: 0 Number of bytes returned: 2 Related Commands: HP (Hopping Channel), ID (Module VID), MK (Address Mask) E0 (Echo Off) ...
Page 25
XBee‐PRO® XSC OEM RF Modules E1 (Echo On) Command Command Summary AT Command: ATE1 Binary Command: 0x0B (11 decimal) ER (Receive Error Count) Command Command Summary AT Command: ATER Binary Command: 0x0F (15 decimal) Parameter Range:0 – 0xFFFF Default Parameter Value: 0 Number of ...
Page 26
XBee‐PRO® XSC OEM RF Modules FL (Software Flow Control) Command Command Summary Description AT Command: <Serial Interfacing> FL Command ATFL is used to configure software flow Binary control. Hardware flow control is Command: implemented with the Module as 0x07 (7 the DO2 pin (), ...
Page 27
XBee‐PRO® XSC OEM RF Modules GD (Receive Good Count) Command Command Summary AT Command: ATGD Binary Command: 0x10 (16 decimal) Parameter Range:0 – 0xFFFF Default Parameter Value: 0 Number of bytes returned: 2 Related Commands: ER (Receive Error Count) HP (Hopping Channel) Command Command ...
Page 28
XBee‐PRO® XSC OEM RF Modules HT (Time before Wake-up Initializer) Command Command Summary AT Command: ATHT Binary Command: 0x03 (3 decimal) Parameter Range:0 – 0xFFFF [x 100 milliseconds] Default Parameter Value: 0xFFFF (means that long wake-up initializer will not be sent) Number of bytes ...
Page 29
XBee‐PRO® XSC OEM RF Modules LH (Wake-up Initializer Timer) Command Command Summary AT Command: ATLH Binary Command: 0x0C (12 decimal) Parameter Range:0 – 0xFF [x 100 milliseconds] Default Parameter Value: 1 Number of bytes returned: 1 Related Commands: HT (Time before Wake-up Initializer), SM ...
Page 30
XBee‐PRO® XSC OEM RF Modules NB (Parity) Command Command Summary AT Command: ATNB Binary Command: 0x23 (35 decimal) Parameter Range:0 – 4 Parameter Configuration Value 8-bit (no parity or 0 7-bit (any parity) 1 8-bit even 2 8-bit odd 3 8-bit mark 4 8-bit ...
Page 31
XBee‐PRO® XSC OEM RF Modules PW (Pin Wake-up) Command Command Summary AT Command: ATPW Binary Command: 0x1D (29 decimal) Parameter Range:0 – 1 Parameter Configuration Value 0 Disabled 1 Enabled Default Parameter Value: 0 Number of bytes returned: 1 Related Commands: SM (Sleep Mode), ...
Page 32
XBee‐PRO® XSC OEM RF Modules RO (Packetization Timeout) Command Command Summary AT Command: ATRO Binary Command: 0x21 (33 decimal) Parameter Range:0 – 0xFFFF [x 200 µs] Default Parameter Value: 0 Number of bytes returned (RSSI PWM Timer) Command Command Summary AT ...
Page 33
XBee‐PRO® XSC OEM RF Modules RR (Retries) Command Command Summary AT Command: ATRR Binary Command: 0x18 (24 decimal) Parameter Range:0 – 0xFF Default Parameter Value: 0 (disabled) Number of bytes returned (RSSI) Command Command Summary AT Command: ATRS Binary Command: 0x1C (28 ...
Page 34
XBee‐PRO® XSC OEM RF Modules RT (DI2 Configuration) Command Command Summary AT Command: ATRT Binary Command: 0x16 (22 decimal) Parameter Range:0 – 2 Parameter Configuration Value 0 disabled 1 Enable Binary Programming 2 Enable Flow Control Default Parameter Value: 0 Number of bytes returned: ...
Page 35
XBee‐PRO® XSC OEM RF Modules SM (Sleep Mode) Command Command Summary AT Command: ATSM Binary Command: 0x01 Parameter Range:0,1 3-8 Parameter Configuration Value 0 Disabled 1 Pin Sleep Cyclic 0.5 second sleep 3 (Module wakes every 0.5 seconds) 4 Cyclic 1.0 second sleep 5 ...
Page 36
XBee‐PRO® XSC OEM RF Modules SY (Time before Initialization) Command Command Summary AT Command: ATSY Binary Command: 0x17 (23 decimal) Parameter Range:0 – 0xFF [x 100 milliseconds] Default Parameter Value: 0 (Disabled - channel initialization information is sent with each RF packet.) Number of ...
Page 37
XBee‐PRO® XSC OEM RF Modules TT (Streaming Limit) Command Command Summary AT Command: ATTT Binary Command: 0x1A (26 decimal) Parameter Range:0 – 0xFFFF (0 = disabled) Default Parameter Value: 0xFFFF (65535 decimal) Number of bytes returned: 2 Related Commands: RN (Delay Slots) © 2010 Digi International, Inc. Description ...
Page 38
XBee‐PRO® XSC OEM RF Modules Appendix A: Agency Certifications FCC (United States) Certification The XBee-PRO® XSC OEM RF Module complies with Part 15 of the FCC rules and regulations. Compliance with the labeling requirements, FCC notices and antenna usage guidelines is required. In order to operate under ...
Page 39
XBee‐PRO® XSC OEM RF Modules Final antenna installation and operating configurations of this transmitter including antenna gain and cable loss must not exceed the EIRP of the configuration used for calculating MPE. Grantee (Digi) must coordinate with OEM integrators to ensure the end-users and ...
Page 40
XBee‐PRO® XSC OEM RF Modules Antenna Options: 900 MHz Antenna Listings Table A-01. Antennas approved for use with the XBee-PRO XSC OEM RF Module Part Number Omni-directional antennas A09-F0 A09-F1 A09-F2 A09-F3 A09-F4 A09-F5 A09-F6 A09-F7 A09-F8 A09-F9 A09-W7 A09-F0 A09-F1 A09-F2 A09-F3 A09-F4 ...
Page 41
XBee‐PRO® XSC OEM RF Modules A09-QBMMP6I A09-QI 29000187 A09-QW A09-QRAMM A09-QSM-3 A09-QSM-3H A09-QBMM-P6I A09-QHRN A09-QHSN A09-QHSM-2 A09-QHRSM-2 A09-QHRSM-170 A09-QRSM-380 A09-QAPM-520 A09-QSPM-3 A09-QAPM-3 A09-QAPM-3H A09-DPSM-P12F A09-D3NF-P12F A09-D3SM-P12F A09-D3PNF A09-D3TM-P12F A09-D3PTM A09-M0SM A09-M2SM A09-M3SM A09-M5SM A09-M7SM A09-M8SM A09-M0TM A09-M2TM A09-M3TM A09-M5TM A09-M7TM A09-M8TM Yagi antennas A09-Y6 ...
Page 42
XBee‐PRO® XSC OEM RF Modules A09-Y15 A09-Y15 A09-Y6TM A09-Y7TM A09-Y8TM A09-Y9TM A09-Y10TM A09-Y11TM A09-Y12TM A09-Y13TM A09-Y14TM A09-Y14TM A09-Y15TM A09-Y15TM © 2010 Digi International, Inc. 13 Element Yagi RPN 15 Element Yagi RPN 2 Element Yagi RPTNC 3 Element Yagi RPTNC 4 Element Yagi RPTNC 4 Element Yagi RPTNC ...
Page 43
XBee‐PRO® XSC OEM RF Modules Appendix B: Additional Information 1-Year Warranty WARRANTY PERIOD: Digi warranties hardware Product for a period of one (1) year. WARRANTY PROCEDURE: Upon return of the hardware Product Digi will, at its option, repair or replace Product at no additional charge, freight prepaid, ...
Page 44
XBee‐PRO® XSC OEM RF Modules XStream Compatible Z6 = ZigBee 2006 Z7 = ZigBee 2007 WF = WiFi (802.11) 5 Antenna Type C = Chip H = Helical S = SMA Wire N = None 6 Temperature ...