E8MS-N0 Omron, E8MS-N0 Datasheet - Page 5

SENSOR PRESSURE NEGATIV 0-101KPA

E8MS-N0

Manufacturer Part Number
E8MS-N0
Description
SENSOR PRESSURE NEGATIV 0-101KPA
Manufacturer
Omron
Series
E8MSr
Datasheets

Specifications of E8MS-N0

Pressure Type
Gauge
Operating Pressure
-14.65 ~ +0 PSI, -101 ~ 0 kPa
Port Size
Male, 1/8" (3.175mm) 27 NPT
Output
Digital
Voltage - Supply
12 V ~ 24 V
Termination Style
Cable
Operating Temperature
0°C ~ 50°C
Package / Case
Module
Sensor Output
Voltage
Supply Current
25mA
Voltage Rating
12V
Port Style
NPT, M5
Pressure Measurement Type
Gage
Operating Pressure Min
0psi
Terminal Type
Connector
Operating Pressure Max
14.6psi
Mounting Style
Desktop
Maximum Operating Temperature
+ 50 C
Minimum Operating Temperature
0 C
Operating Supply Voltage
12 V
Output Voltage
1 V to 5 V
Pressure Port
Y
Sensor Type
Sensors
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
E8MSN0
Controllers
* Pressure differentials are displayed with a minus (−) sign.
Item
Connectable Pressure
Sensor
Power supply voltage
Current consumption
Sensor power supply
Input
Output
Autoshift input
Indica-
tors
Response speed
Set resolution
Display accuracy
Protection circuits
Ambient temperature
range
Ambient humidity range Operating/Storage: 35% to 85% (with no condensation)
Temperature influence
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Degree of protection
Connection method
Weight
Accessories
Sensor input
(through 4-pin
one-touch
connector)
Comparative
output
Measurement
value
Message
Measurement
and setting
channel
Comparative
output
Others
Model
E8M-A1-S
Differential pressure from 0
to 1,000 Pa between posi-
tive and negative ports
24 VDC ±10%, ripple (p-p) of 10% max.
200 mA max. (including sensor section current consumption of 30 mA per channel)
Supplied from the Controller, 12 VDC±10% (30 mA max. per channel)
Input voltage range: 1 to 5 VDC with an impedance of 800 kΩ per channel
NPN open collector
Maximum load current: 80mA max.
Load voltage: 30 VDC max.
Residual voltage: 0.8 V max. with a flow current of 30 mA, 0.4 V max. with a flow current of 16 mA
NO or NC (selectable) independent output in hysteresis or window mode (selectable) on each channel
Non-voltage input (contact or non-contact), Input: 10 ms min.
LED indicator (orange) with a character height of 9 mm for 4 digits.
LED indicator (orange) with a character height of 9 mm for 4 digits.
LED indicator (red) with a character height of 5 mm for 1 digit.
LED indicator (red) that is lit when the output transistor is turned ON
LED indicator (green) for connecting channel and unit display (green)
5 ms max. (The response speed will switch to 20 ms, 160 ms, or 640 ms when chattering prevention is enabled.)
±0.1% FS max.
±0.5% FS ±1 digit max. (at ambient temperature of 25°C)
Reverse polarity protection, load short-circuit protection
Operating: 0 to 50°C
Storage:
±0.5 FS max. (25°C reference)
100 MΩ min. (at 500 VDC) between current-carrying parts and case
1,000 VAC for 1 min
Destruction: 10 to 150 Hz, 0.75-mm single amplitude or 100 m/s
power supplied)
Destruction: 300 m/s
IEC 60529, Front surface only: IP65 (when panel mounted), Otherwise: IP30
Panel mounting
Power supply and output: 8-pin terminal
Sensor I/O: 4-pin e-CON connector
Approx. 55 g (not including accessories)
Instruction manual, Adapter, Water-proof Packing
*
−20 to 60°C (with no icing)
2
3 times each in X, Y and Z directions (with power supplied)
E8MS-01
(0 to 100 kPa)
E8M-MP8
E8MS-10
E8M-10
(0 to 1 MPa)
2
, 4 times each for 8 min in X, Y and Z directions (with
E8MS-N0
E8M-N0
(0 to −101 kPa)
E8MS/E8M
5