A22-24AY Omron, A22-24AY Datasheet - Page 215

LAMP A22 SERIES 24VAC/DC LED YLW

A22-24AY

Manufacturer Part Number
A22-24AY
Description
LAMP A22 SERIES 24VAC/DC LED YLW
Manufacturer
Omron
Type
LED, 10.6 mm Diameterr
Series
A22r
Datasheets

Specifications of A22-24AY

Accessory Type
LED Lamp Replacement
Color
Yellow
Illumination
Illuminated
Contact Rating
8 mAmps at 24 VoltsAC/DC
Height
20 mm
Illumination Color
Yellow
Mounting Style
Snap In
Termination Style
Socket
For Use With/related Products
A22 Series
For Use With
Z1496 - SWITCH PB RND MOM SPST-NO ILLZ1495 - SWITCH PB ILL RND MOM SPST-NOZ1492 - SWITCH PB RND MOM SPST-NC ILLZ1494 - SWITCH PB ILL RND MOM SPST-NOZ1486 - SWITCH PB ILL RND MOM SPST-NOZ1485 - SWITCH PB ILL RND MOM SPST-NOZ1482 - SWITCH PB RND MOM SPST-NC ILLZ1484 - SWITCH PB ILL RND MOM SPST-NOZ1483 - SWITCH PB RND MOM SPST-NO ILLZ1477 - SWITCH PB SQ MOM SPST-NO ILL-YLWZ1476 - SWITCH PB SQ MOM SPST-NO ILL-WHTZ1475 - SWITCH PB SQ MOM SPST-NO ILL-GRNZ1474 - SWITCH PB SQ MOM SPST-NO ILL-BLU
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
A2224AY
Z1578
A3A
Note: 1. With alternate-action models, a setting and resetting is regarded as one operation.
UL (File No. E41515)/CSA (File No. LR45258)
SPST-NO: 6 A at 125 VAC, 2 A at 250 VAC, 4 A at 30 VDC
SPDT: 3 A at 125 VAC, 2 A at 30 VDC
Note: The above lock stroke figure applies to A3A alternate
Operating frequency
Insulation resistance
Contact resistance
Dielectric strength
Vibration resistance
Shock resistance
Life expectancy
Weight
Ambient temperature
Ambient humidity
Degree of protection
Electric shock protection class
PTI (proof tracking index)
Pollution degree
OF max.
RF min.
TT
PT max.
LTA min. (See note.)
Characteristics
Approved Standards
Operating Characteristics
2. The figure for the dielectric strength between LED terminals in the above table is for when the LED is not installed in the Switch.
3. The figures for malfunctions in the above table are for malfunctions of at least 1 ms.
operation models only.
2.45 N
0.15 N
Approx. 2 mm
1.5 mm
0.5 mm
Mechanical:
Electrical: 20 operations/minute max.
100 MΩ min. (at 500 VDC)
100 mΩ max. (initial value)
600 VAC, 50/60 Hz for 1 min between terminals of same polarity
2,000 VAC, 50/60 Hz for 1 min between each terminal and ground
600 VAC, 50/60 Hz for 1 min between LED terminals (See note 2.)
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude (See note 3.)
Destruction: 500 m/s
Malfunction: 150 m/s
Mechanical:
Electrical: 50,000 operations min.
Approx. 3.2 g
Operating: –10°C to 55°C (with no icing)
Storage:
Operating: 35% to 85%
IP00
Class II
175
3 (IEC947-5-1)
Momentary action:
Alternate action:
Momentary action:
Alternate action:
–25°C to 65°C
2
2
(See note 3.)
120 operations/minute max.
60 operations/minute max. (See note 1.)
1,000,000 operations min.
50,000 operations min. (See note 1.)
A3A
213