79222641 Crouzet USA, 79222641 Datasheet - Page 111

no-image

79222641

Manufacturer Part Number
79222641
Description
WHT STRIKER PINS-PROG CAM 30PC
Manufacturer
Crouzet USA
Datasheet

Specifications of 79222641

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For more information www.crouzet.com
Connections
LN
Principles
Emptying control
R S T
B
C
D
E
F
G
H
M
3
Max. level
Min. level
Output relay
Down
Unit power-up
Controlled level
Empty function
P
1
2
4
Un
3
3
4
Max.
2
5
1
Min.
11
6
10
7
2
8
9
T
1
3
2
1
4
2
4
8
5
5
6
7
6
7
B
C
D
E
Input
Common
‘LN’ 11-pin
‘LN’ 8-pin
Operating principle
Control of maximum and/or minimum levels of conductive liquids (tap water, sea water, waste
water, chemical solutions, coffee etc).
The principle is based on measurement of the apparent resistance of the liquid between two
submerged probes. When this value is lower than the preset threshold on the unit front face, the
output relay changes state. To avoid electrolytic phenomena, an AC current funs across the
probes. Applications found in environmental, chemical industries and food technology etc.
Regulation of two levels : Minimum / Maximum
The output relay changes state when the level of liquid reaches the maximum electrode, with the
minimum electrode submerged. It returns to its initial state when the minimum probe is no longer in
contact with the liquid.
Note
The probe wire (maximum 100 metres) does not have to be screened, but avoid mounting it in
parallel with the power supply wires. A screened wire can be used, with the screening connected to
the common.