SI3015-KS Silicon Laboratories Inc, SI3015-KS Datasheet - Page 54

no-image

SI3015-KS

Manufacturer Part Number
SI3015-KS
Description
IC SI2400 LINE-SIDE DAA 16SOIC
Manufacturer
Silicon Laboratories Inc
Type
Enhanced Global Direct Access Arrangementr
Datasheet

Specifications of SI3015-KS

Package / Case
16-SOIC (0.154", 3.90mm Width)
Data Format
V.90
Interface
Serial
Voltage - Supply
3.3 V ~ 5 V
Mounting Type
Surface Mount
Product
Modem Module
Supply Current
0.3 mA
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Baud Rates
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Contains lead / RoHS non-compliant
Other names
336-1094

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SI3015-KS
Manufacturer:
SILICON
Quantity:
35
Part Number:
SI3015-KS
Manufacturer:
SILICON
Quantity:
10 000
Part Number:
SI3015-KS
Manufacturer:
SILICON LABS/芯科
Quantity:
20 000
Company:
Part Number:
SI3015-KS
Quantity:
214
Company:
Part Number:
SI3015-KS
Quantity:
214
Part Number:
SI3015-KSR
Manufacturer:
SILICON LABS/芯科
Quantity:
20 000
Si2400
S14 (MF4). Modem Functions 4
Reset settings = 0000_0000
54
Name
Type
Bit
Bit
7
6
5
4
3
2
1
0
MRCD
R/W
D7
MRCD
Name
AOC
UDF
TEO
NLD
IND
OD
RD
UDF
R/W
D6
Disable Modem Result Codes. (See S62 also.)
0 = Enables the following modem result codes:
1 = Disables the following modem result codes:
Intrusion—”i” and “ I ”
Line present—”l” and “L”
Flash—”f”
Ring—”R”
Register S62 can be used to individually re-enable particular result codes.
User Defined Frequency.
0 = Disable.
1 = Enable user defined frequency detectors in A0 and !0 modes.
TIES Escape Operation.
0 = Disable TIES escape operation.
1 = Enable TIES.
AutoOverCurrent Detection.
0 = Disables AutoOverCurrent detection.
1 = Enables AutoOverCurrent detection.
Overcurrent Detected (Sticky).
No Phone Line.
This bit is sticky while off-hook if S82[3] (LCLD) = 1
hook. NLD remains sticky for 800 ms after going from off-hook to on-hook.
Intrusion Detected.
This bit is normally NOT sticky so that the user may monitor/poll for intrusion manually.
However, during dialing and during data mode, it is impossible to monitor/poll this bit.
Therefore, if the Si2400 is either dialing or in data mode, this bit is sticky. If triggered dur-
ing data mode, this bit will remain sticky for 800 ms after the Si2400 goes back on-hook.
Ring Detected (Sticky).
This bit is normally sticky, but is cleared when the Si2400 goes from on-hook to off-hook.
b
(0x00)
TEO
R/W
D5
AOC
R/W
D4
R/W
OD
D3
Rev. 1.3
NLD
R/W
D2
Function
R/W
IND
D1
b
, and non-sticky (status) while on-
R/W
RD
D0

Related parts for SI3015-KS