Y92P-CXT4S Omron, Y92P-CXT4S Datasheet - Page 25

Mounting Hardware Front Panels - Rplc White (5Y9.2 / 0.5)

Y92P-CXT4S

Manufacturer Part Number
Y92P-CXT4S
Description
Mounting Hardware Front Panels - Rplc White (5Y9.2 / 0.5)
Manufacturer
Omron
Type
Front Panel Replacementr
Datasheet

Specifications of Y92P-CXT4S

Color
White
Features
Cover for Timer with 4 Digits
Product
Hardware
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
H5CX Series Timers
Setting Procedure Guide
Operating Procedures for Twin Timer Function
After making DIP switch settings for basic operation, advanced functions can be added using the operation keys on the front panel. Refer to
Step3
Note: All the pins are factory-set to OFF.
Step1
Step2
Be sure to turn ON pin 1 on the DIP switch.
Changes to DIP switch settings are enabled when the power is turned ON.
(Perform DIP switch settings while the power is OFF.)
1
2
3
4
5
6
7
8
on page 26 for details.
Power ON
Run mode
DIP switch settings
OFF time range
ON time range
Output mode
Timer mode
Input signal width
Switching to a Twin Timer
Settings for basic functions can be performed with just the DIP switch.
Note: There is no DIP switch on the H5CX-L8@. Go to
Item
Key-protect Switch
Hold down for 1 s min.
Hold down for 1 s min.
+
+
Flicker OFF start
1
1
Refer to the table on the right.
Refer to the table on the right.
Disabled
20 ms
OFF
Timer/twin timer
selection mode
UP
Flicker ON start
Enabled
tim
DOWN
Timer
1 ms
Press the
switch to a Twin Timer.
ON
OFF
ON
Twin timer
1 2 3 4 5 6 7 8
twn
Be sure to set pin 1 to ON when using the DIP switch.
or
Key to
Step3
Pin 2
Pin 4
OFF
OFF
OFF
OFF
ON
ON
ON
ON
.
Pin 3
Pin 5
OFF
OFF
OFF
OFF
ON
ON
ON
ON
H5CX-A@-N/-L@-N
0 min 01 s to 99 min 59 s
0 min 01 s to 99 min 59 s
0.01 s to 99.99 s
OFF time range
0.1 s to 999.9 s
ON time range
0.01 s to 99.99 s
0.1 s to 999.9 s
1 s to 9999 s
1 s to 9999 s
Twin Timer
25