MAP110-1024 POWER ONE, MAP110-1024 Datasheet - Page 4

Linear & Switching Power Supplies 110W 24V 3.8A 28V 3.2A

MAP110-1024

Manufacturer Part Number
MAP110-1024
Description
Linear & Switching Power Supplies 110W 24V 3.8A 28V 3.2A
Manufacturer
POWER ONE
Type
Open Framer
Datasheet

Specifications of MAP110-1024

Product
Switching
Commercial/medical
Commercial
Output Power Rating
90 W
Input Voltage
85 VAC to 264 VAC
Number Of Outputs
1
Output Voltage (channel 1)
24 V, 28 V
Output Current (channel 1)
3.8 A, 3.2 A
Mounting Style
Chassis
Dimensions
7 in L x 4.3 in W x 1.97 in H
Output Current (max)
3.8/3.2A
Output Voltage
24/28V
Output Power (max)
80W
Input Frequency
47 to 63Hz
Efficiency
80%
Screening Level
Commercial
Product Length (mm)
177.8mm
Product Height (mm)
50mm
Product Depth (mm)
109.2mm
Operating Temperature Min Deg. C
0C
Operating Temperature Max Deg. C
70C
Pin Count
19
Brand/series
MAP110 Series
Configuration
Open-Frame
Current, Input
3.5 A (RMS)(85 VAC), 2.8 A (RMS)(110 VAC)
Current, Output
3.8⁄3.2 A (Convection Cooled), 5⁄4.3 A (Forced Air)
Frequency, Operating
47 to 63 Hz (AC Input), 20 to 25 kHz (Operating)
Line Regulation
0.1%
Load Regulation
0.5%
Mounting Type
Panel
Operation
Switching
Output
24 VDC @ 5 A/28 VDC @ 4.3 A
Power, Output
110 W
Power, Rating
110 W
Primary Type
AC-DC
Special Features
Remote Sense
Standards
UL Listed, CSA Certified
Temperature, Operating
0 to +50 °C
Voltage, Input
85 to 264 VAC
Voltage, Output
24/28 VDC
En61000-4-2 Esd Level 4 (8 Kv)
All Map Products
En61000-4-3 Radiated Level 3 (10 V/m)
All Map Products
Universal Input
90-132 VAC or 175-264 VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
MCD10142 Rev. 1.0, 27-Jan-10
Environmental Specifications
PARAMETER
Altitude
Operating Temperature
Storage Temperature
Temperature Coefficient
Relative Humidity
Options
DESCRIPTION
L-Bracket
Cover
Power Fail
Signal
Thermal
Shutdown
CONDITIONS/DESCRIPTION
Operating.
Non-operating.
Derate linearly above 50°C by 2.5% per° C
to a maximum temperature of 70°C.
0°C to 70°C.
Non-condensing.
NOTES
Add ‘L’ suffix to model number.
Add ‘C’ suffix to model number. Includes L-Bracket.
Add ‘P’ suffix to model number. Provides >5 mS typical warning time before
main output drops 5%. Warning time increases at reduced load levels.
Add ‘T’ suffix to model number. Initiates shut-down in the event of an overtemperature
condition. Automatic recovery.
Page 4 of 5
MAP110 AC-DC Series Data Sheet
At 100% load:
At 50% load:
MIN
-55
0
0
(182.0mm x 115.0mm x 61.0mm)
(183.0mm x 115.0mm x 61.0mm)
±0.03
NOM
7.15" x 4.50" x 2.40"
7.20" x 4.50" x 2.40"
www.power-one.com
DIMENSIONS
N/A
N/A
±0.05
MAX
10k
50k
50
70
85
95
ASL Ft.
ASL Ft.
UNITS
%/°C
%RH
°C
°C
°C