DTB47-3X-W ETA-USA, DTB47-3X-W Datasheet

no-image

DTB47-3X-W

Manufacturer Part Number
DTB47-3X-W
Description
Plug-In AC Adapters 47 WATTS +5/+12/-12
Manufacturer
ETA-USA
Datasheet

Specifications of DTB47-3X-W

Mounting Style
Wall
Input Voltage (nominal)
110 VAC to 220 VAC
Number Of Outputs
3
Output Power Rating
47 W
Output Voltage (channel 1)
5 V
Output Current (channel 1)
7 A
Output Voltage (channel 2)
12 V
Output Current (channel 2)
1.5 A
Dc Output Connector
8 Pin DIN
Ac Plug Included/required
Required
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
GENERAL SPECIFICATION
This specification describes the performance
characteristics of a grounded, single phase, 47
watts, 3 output level adapter power supply.
1) INPUT
2) OUTPUT
+5V/7A; +12V/1.5A; -12V/0.3A; TOTAL OUTPUT: 47W MAX.
2.1)
NOTE: 20MHz bandwidth ripple & noise is measured by using 0.1uF C.C. & 10uF/50V
2.2)
ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com
V1
V2
V3
INRUSH CURRNET
HOLD UP TIME
Line Frequency
STATIC DC LOAD & RIPPLE NOISE
Description
The power supply unit should maintain its proper voltage within voltage specifications for at least 10 mS after losing
Input Voltage
input power under the condition of 115VAC (or 230VAC) input voltage and max. output load.
Input Current
VOLTAGE
NOMINAL
E.C. bypassed at the output connector.
Efficiency
+12V
+5V
-12V
RoHS
1.0A MAX. (RMS)
-10.80V
11.40V
90VAC
MIN.
4.85V
Min.
47Hz
-
LIMIT
60A MAX. (COLD START AT MAX. LOAD & 220VAC INPUT)
110/220V 264VAC
Typical
50/60Hz
-13.20V
30A MAX. (COLD START AT MAX. LOAD & 110VAC
12.60V
MAX.
5.25V
-
Max.
0.01A
63Hz
70%
MIN.
1.0A
0.1A
AVERAGE LOAD
7.0A
MAX.
1.5A
0.3A
AC normal input & the Maximum load
Full Range; 50/60Hz
RIPPLE & NOISE
AC/DC SWITCHING ADAPTOR
Condition
120mV
120mV
50mV
-
DTB47-3X-W
TRIPLE OUTPUT
47 WATT

Related parts for DTB47-3X-W

DTB47-3X-W Summary of contents

Page 1

... AC normal input & the Maximum load LIMIT AVERAGE LOAD MAX. MIN. MAX. 5.25V 1.0A 7.0A 12.60V 0.1A 1.5A -13.20V 0.01A 0.3A 47 WATT TRIPLE OUTPUT AC/DC SWITCHING ADAPTOR DTB47-3X-W Condition Full Range; 50/60Hz - RIPPLE & NOISE 50mV 120mV 120mV ...

Page 2

... EN55022 PART 15 class "B" FCC CERTIFICATE 5.1 ) DIELECTRIC WITHSTAND Primary to Secondary: 3000VAC for 60 Sec. Primary to Frame Ground: 1500VAC for 60 Sec. Secondary to Ground: 500VAC for 60 Sec. ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com OVERVOLTAGE RANGE (V) FROM 5 degree centigrade percent, non-condensing -25 to +85 degree centigrade percent, non-condensing TO 6 ...

Page 3

... MECHANICAL REQUIREMENT 8.1) : 132( 69( 40(H) mm. CASE DIMENSION 8.2) OUTPUT CONNECTOR ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com : DEPENDS ON YOUR REQUIREMENTS OUTPUT CABLE LENGTH: 1500 ± 50mm OUTPUT CONNECTOR: 8P DIN INPUT CONNECTOR: IEC320-C13 (3 pins) ...

Page 4

... ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com ...