DTB47-3X-W ETA-USA, DTB47-3X-W Datasheet - Page 2

no-image

DTB47-3X-W

Manufacturer Part Number
DTB47-3X-W
Description
Plug-In AC Adapters 47 WATTS +5/+12/-12
Manufacturer
ETA-USA
Datasheet

Specifications of DTB47-3X-W

Mounting Style
Wall
Input Voltage (nominal)
110 VAC to 220 VAC
Number Of Outputs
3
Output Power Rating
47 W
Output Voltage (channel 1)
5 V
Output Current (channel 1)
7 A
Output Voltage (channel 2)
12 V
Output Current (channel 2)
1.5 A
Dc Output Connector
8 Pin DIN
Ac Plug Included/required
Required
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3)PROTECTION:
4) ENVIRONMENT:
5) SAFETY PROVIDED
ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com
3.3)
3.1)
If any over voltage occurs, the power supply should latch off before any output exceeds its limit below.
The power supply will be automatically recovered after the over voltage fault being removed.
3.2)
4.2)
4.1)
5.1
OVERLOAD PROTECTION.
OVER VOLTAGE PROTECTION (OVP)
An over load protection will be effected when overloading reaches +160% MAX the power supply will
be automatically recovered after the overload being removed.
SHORT CIRCUIT PROTECTION
FCC CERTIFICATE
UL 1950
CSA 22.2
TUV EN60950
CE
Short circuit occurred on +5V, +12V output should not cause any damage to the power supply but shut down the
power supply. The power supply will be automatically recovered after the short circuit being removed.
SHIPPING AND STORAGE:
OPERATING:
)
DIELECTRIC WITHSTAND
EN55022 PART 15 class "B"
VOLTAGE (V)
Temperature:
Temperature:
Primary to Secondary: 3000VAC for 60 Sec.
Primary to Frame Ground: 1500VAC for 60 Sec.
Secondary to Ground: 500VAC for 60 Sec.
Relative Humidity:
Relative Humidity:
NOMINAL
+5
0 to 40 degree centigrade
-25 to +85 degree centigrade
20 to 90 percent, non-condensing
20 to 90 percent, non-condensing
FROM
5.6
OVERVOLTAGE RANGE (V)
TO
6.5