LM25066APSQE/NOPB National Semiconductor, LM25066APSQE/NOPB Datasheet - Page 31

IC CTLR PM HOTSWAP 24-LLP

LM25066APSQE/NOPB

Manufacturer Part Number
LM25066APSQE/NOPB
Description
IC CTLR PM HOTSWAP 24-LLP
Manufacturer
National Semiconductor
Series
PowerWise®r
Datasheets

Specifications of LM25066APSQE/NOPB

Applications
Base Station-Networking Line Cards, Servers
Current - Supply
5.8mA
Voltage - Supply
2.9 V ~ 17 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
*
Package / Case
*
Input Voltage
17V
Internal Switch
No
Supply Voltage Range
2.9V To 5.5V
Rohs Compliant
Yes
Digital Ic Case Style
LLP
No. Of Pins
24
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
LM25066APSQE/NOPBTR
STATUS_VOUT (7Ah)
The STATUS_VOUT command is a standard PMBus ™ com-
mand that returns the value of the VOUT UV Warn flag.
Accesses to this command should use the PMBus ™ read
STATUS_INPUT (7Ch)
The STATUS_INPUT command is a standard PMBus ™ com-
mand that returns the value of a number of flags related to
input voltage, current, and power. Accesses to this command
should use the PMBus ™ read byte protocol. To clear bits in
STATUS_TEMPERATURE (7dh)
The STATUS_TEMPERATURE is a standard PMBus ™ com-
mand that returns the value of the of a number of flags related
to the temperature telemetry value. Accesses to this com-
Bit
Bit
Bit
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
VOUT Tracking Error
Insufficient Voltage
Undertemp Warn
Undertemp Fault
TOFF Max Fault
VOUT OV Warn
VOUT UV Warn
Overtemp Warn
VOUT OV Fault
VOUT UV Fault
Overtemp Fault
TON Max Fault
VIN OV Warn
VIN UV Warn
PIN OP Warn
VIN OV Fault
VIN UV Fault
IIN OC Warn
IIN OC Fault
VOUT Max
reserved
reserved
reserved
reserved
NAME
NAME
NAME
TABLE 13. STATUS_TEMPERATURE Definitions
TABLE 12. STATUS_INPUT Definitions
TABLE 11. STATUS_VOUT Definitions
A VOUT Under-voltage Warning has occurred
An over-temperature Warning has occurred
A VIN Under-voltage Warning has occurred
A VIN Over-voltage Warning has occurred
An IIN Over-current Warning has occurred
A PIN Over-power Warning has occurred
An over-temperature Fault has occurred
31
A VIN Under-voltage Fault has occurred
A VIN Over-voltage Fault has occurred
An IIN Over-current Fault has occurred
byte protocol. To clear bits in this register, the underlying fault
should be removed and a CLEAR_FAULTS command is-
sued.
this register, the underlying fault should be removed and a
CLEAR_FAULTS command issued. The IN UV Warn flag will
default to 1 on startup. However, it will be cleared to 0 after
the first time the input voltage exceeds the resistor pro-
grammed UVLO threshold.
mand should use the PMBus ™ read byte protocol. To clear
bits in this register, the underlying fault should be removed
and a CLEAR_FAULTS command issued.
Not Supported, always 0
Not Supported, always 0
Not Supported, always 0
Not Supported, always 0
Not Supported, always 0
Not Supported, always 0
Not Supported, always 0
Not Supported, always 0
Not Supported, always 0
Not Supported, always 0
Not Supported, always 0
Not Supported, always 0
Not Supported, always 0
Not Supported, always 0
Meaning
Meaning
Meaning
www.national.com
Default
Default
Default
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
0