TMP03FT9 Analog Devices Inc, TMP03FT9 Datasheet - Page 3

no-image

TMP03FT9

Manufacturer Part Number
TMP03FT9
Description
IC SENSOR TEMP/SERIAL OC TO-92-3
Manufacturer
Analog Devices Inc
Datasheet

Specifications of TMP03FT9

Mounting Type
Through Hole
Package / Case
TO-92-3 (Standard Body), TO-226
Rohs Status
RoHS non-compliant
Function
Temp Monitoring System (Sensor)
Topology
ADC (Sigma Delta), Digital Modulator
Sensor Type
Internal
Sensing Temperature
-40°C ~ 100°C
Output Type
Open Collector
Output Alarm
No
Output Fan
No
Voltage - Supply
4.5 V ~ 7 V
Operating Temperature
-55°C ~ 150°C
Ic Function
Temperature Sensor IC
Termination Type
Through Hole
Lead Free Status / RoHS Status

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TMP03FT9Z
Manufacturer:
YCL
Quantity:
1 000
Part Number:
TMP03FT9Z
Manufacturer:
ADI/亚德诺
Quantity:
20 000
ABSOLUTE MAXIMUM RATINGS
Maximum Supply Voltage . . . . . . . . . . . . . . . . . . . . . . . . . 9 V
Maximum Output Current (TMP03 D
Maximum Output Current (TMP04 D
Maximum Open-Collector Output Voltage (TMP03) . . . 18 V
Operating Temperature Range . . . . . . . . . . –55°C to +150°C
Dice Junction Temperature . . . . . . . . . . . . . . . . . . . . . . 175°C
Storage Temperature Range . . . . . . . . . . . . –65°C to +160°C
Lead Temperature (Soldering, 60 sec) . . . . . . . . . . . . . 300°C
1
2
3
Package Type
TO-92 (T9)
SO-8 (S)
TSSOP (RU)
NOTE
1
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection.
Although the TMP03 features proprietary ESD protection circuitry, permanent damage may
occur on devices subjected to high-energy electrostatic discharges. Therefore, proper ESD
precautions are recommended to avoid performance degradation or loss of functionality.
Stresses above those listed under Absolute Maximum Ratings may cause perma-
Digital inputs and outputs are protected, however, permanent damage may occur
Remove power before inserting or removing units from their sockets.
Θ
CAUTION
nent damage to the device. This is a stress rating only; functional operation at or
above this specification is not implied. Exposure to the above maximum rating
conditions for extended periods may affect device reliability.
on unprotected units from high-energy electrostatic fields. Keep units in conduc-
tive foam or packaging at all times until ready to use. Use proper antistatic
handling procedures.
JA
is specified for device in socket (worst case conditions).
162
158
240
JA
1
1
1
OUT
OUT
120
43
43
JC
) . . . . . . . . . 50 mA
) . . . . . . . . . 10 mA
Units
°C/W
°C/W
°C/W
Model
TMP03FT9
TMP03FS
TMP03FRU
TMP04FT9
TMP04FS
Accuracy
at 25 C
± 3.0
± 3.0
± 3.0
± 3.0
± 3.0
ORDERING GUIDE
WARNING!
Temperature
Range
XIND
XIND
XIND
XIND
XIND
TMP03/TMP04
ESD SENSITIVE DEVICE
Package
TO-92
SO-8
TSSOP-8
TO-92
SO-8

Related parts for TMP03FT9