70-841-026 Emerson Network Power, 70-841-026 Datasheet

no-image

70-841-026

Manufacturer Part Number
70-841-026
Description
LPT100-M CONNECTOR KIT
Manufacturer
Emerson Network Power
Series
LPT100-Mr
Datasheet

Specifications of 70-841-026

Accessory Type
Connector Kit
For Use With
454-1460 - PWR SUP MED TRI 5V,15V,-15V 130W454-1459 - PWR SUP MED TRI 5V,12V,-12V 130W454-1479 - PWR SUP MED TRI 3.3V,5V,12V 130W454-1480 - PWR SUP MED 5V 24V 12V 130W 2X4"
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
LPT100-M Series
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
454-1366
Safety
• TUV 60950, 60601-1
• UL
• CSA
• NEMKO
• AUSTEL
• CB
• CE
Total Power:
Input Voltage:
# of Outputs:
Special Features
• Medical and ITE safeties
• Active power factor correction
• 2” x 4” footprint
• Less than 1U high
• EN61000-3-2 compliant
• Remote sense
• Power fail
• Adjustable main output
• Built-in Class B EMI filter
• Overvoltage protection
• Overload protection
• Thermal overload protection
• LPX50 enclosure kit available
LPT100-M Series
130 Watts
60950, 60601-1
60950, 60601-1
60950, 60601-1
Certificate & report
Mark (LVD)
60950, 60601-1
80 - 130 Watts
90 - 264 Vac
Triple
Electrical Specifications
Input
Input ra n ge:
Frequency:
Inrush current:
Efficiency:
EMI/RFI:
Safety ground
leakage current:
Output
Maximum power:
Adjustment range:
Hold-up time:
Overload protection:
Overvoltage protection: 15 - 35% above nominal output
Logical Control
Power failure:
Remote sense:
90 - 264 Vac; 127 - 300 Vdc
47 - 63 Hz
50 A max., cold start @ 25 °C
82% typical at full load
FCC Class B conducted; CISPR22 Class B conducted;
EN55022 Class B conducted; VDE0878PT3 Class B conducted
2 75 µA @ 50/60 Hz, 264 Vac input
80 W for convection;
130 W with 200 LFM forced air
All outputs adjustable: -20%, +10%, except for +24V output on LPT104-M
which will be -10%, +20% and 3.3 V output on the LPT101-M +10%, -15%
10 ms @ 130 W load, 120 Vac input
Short circuit protection on all outputs. Case overload
protected @ 110 - 160% above rating for V1 & V2, 150 - 250% for V3
Active LowTTL logic signal goes high 100 - 500 msec after main output; it
goes low at least 6 msec before loss of regulation
C ompensates for 0.5 V lead drop min. Will operate without remote sense
connected. Reverse connection protected.
Embedded Power for
Business-Critical Continuity
Rev. 01.14.11_141
LPT100-M Series
1 of 3

Related parts for 70-841-026

70-841-026 Summary of contents

Page 1

LPT100-M Series 130 Watts Total Power 130 Watts Input Voltage 264 Vac # of Outputs: Triple Special Features • Medical and ITE safeties • Active power factor correction • 2” x 4” footprint • Less than 1U high • EN61000-3-2 compliant • Remote sense • Power fail • Adjustable main output • Built-in Class B EMI filter • Overvoltage protection • ...

Page 2

... Environmental Specifications Operating temperature: 0° °C ambient derate each output as 2.5% per degree from 50° °C. -20 °C start up Storage temperature: -40 °C to +85 °C Electromagnetic designed to meet EN61000-4; susceptibility: -2, -3, -4, -5, -6, -8, -11 Level 3 Humidity: Operating; non-condensing 10% to 90% RH, non-operating, non-condensing 10% - 95% Vibration: IEC68-2-6 to the levels of IEC721-3-2 MTBF calculated: 583,000 hours at full load and 25 °C ambient conditions. 230 Vac input, Bellcore Mechanical Drawing GND ...

Page 3

... Mating Connectors AC Input (SK1): Molex P/N 09-50-3031 PINS: 08-52-0072 AC Ground: Molex P/N 01-9002001 DC Output (SK2): JST P/N VHR-8N PINS: SVH-21T-P1.1 Remote Sense (SK3): Molex P/N 51065-0400 PINS: 50212-8100 Emerson Network Power Connector Kit #70-841-026, includes all of the above Embedded Power for Business-Critical Continuity Americas 5810 Van Allen Way Ripple Carlsbad, CA 92008 P/P 2 USA (PARD) 3 Telephone: +1 760 930 4600 ± ...

Related keywords