ACS710KLATR-25CB-T Allegro Microsystems Inc, ACS710KLATR-25CB-T Datasheet - Page 3

IC, CURRENT SENSOR, 11mA, 16-SOIC

ACS710KLATR-25CB-T

Manufacturer Part Number
ACS710KLATR-25CB-T
Description
IC, CURRENT SENSOR, 11mA, 16-SOIC
Manufacturer
Allegro Microsystems Inc
Series
-r
Datasheet

Specifications of ACS710KLATR-25CB-T

Quiescent Current
11mA
Bandwidth
120kHz
Sensor Case Style
SOIC
No. Of Pins
16
Supply Voltage Range
3V To 5.5V
Operating Temperature Range
-40°C To +125°C
Msl
MSL 3 - 168 Hours
Featured Product
ACS710 Current Sensor IC
Current - Sensing
±25A
Accuracy
±4.05%
Sensitivity
28mV/A
Current - Supply
11mA
Sensor Type
Hall Effect
Voltage - Supply
3 V ~ 5.5 V
Output
2.5V
Frequency
120kHz
Response Time
4µs
Polarization
Bidirectional
Operating Temperature
-40°C ~ 125°C
Package / Case
16-SOIC (0.295", 7.50mm Width)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ACS710KLATR-25CB-T
Manufacturer:
ROHM
Quantity:
6 258
Part Number:
ACS710KLATR-25CB-T
Manufacturer:
ALLEGRO/雅丽高
Quantity:
20 000
Company:
Part Number:
ACS710KLATR-25CB-T
Quantity:
12 000
Company:
Part Number:
ACS710KLATR-25CB-T
Quantity:
30
ACS710
IP+
IP+
IP+
IP+
IP–
IP–
IP–
IP–
Pin-out Diagram
FAULT_EN
1
2
3
4
5
6
7
8
VOC
IP+
IP–
16
15
14
13
12
11
10
9
FAULT_EN
VOC
VCC
FAULT
VIOUT
FILTER
VZCR
GND
Sensitivity
Bias
Hall
Trim
Hall
Amplifier
Terminal List Table
1 through 4
5 through 8
Current Sensor with Integrated Overcurrent Detection
Number
Recovery
10
11
12
13
14
15
16
9
Signal
VCC
POR
FAULT_EN Enables overcurrent faulting when high. Resets ¯ F ¯ ¯ A ¯ U ¯ ¯ L ¯ ¯ T ¯ when low.
Functional Block Diagram
FILTER
VIOUT
¯ F ¯ ¯ A ¯ U ¯ ¯ L ¯ ¯ T ¯
Name
VZCR
GND
VCC
VOC
IP+
IP–
GND
Fault
Comparator
120 kHz Bandwidth, High Voltage Isolation
Sensed current copper conduction path pins. Terminals for current being sensed;
fused internally, loop to IP– pins; unidirectional or bidirectional current flow.
Sensed current copper conduction path pins. Terminals for current being sensed;
fused internally, loop to IP+ pins; unidirectional or bidirectional current flow.
Device ground connection.
Voltage Reference Output pin. Zero current (0 A) reference; output voltage on this
pin scales with V
Filter pin. Terminal for an external capacitor connected from this pin to GND to set
the device bandwidth.
Analog Output pin. Output voltage on this pin is proportional to current flowing
through the loop between the IP+ pins and IP– pins.
Overcurrent Fault pin. When current flowing between IP+ pins and IP– pins
exceeds the overcurrent fault threshold, this pin transitions to a logic low state.
Supply voltage.
Overcurrent Input pin. Analog input voltage on this pin sets the overcurrent fault
threshold.
OC Fault
R
F(INT)
CC
FAULT Reset
.
FILTER
+
+
POR
2V
REF
V
Description
Trim
OUT(Q)
Control
Logic
115 Northeast Cutoff
1.508.853.5000; www.allegromicro.com
Allegro MicroSystems, Inc.
Worcester, Massachusetts 01615-0036 U.S.A.
D
CLK
R
Fault Latch
Q
3 mA
Drain
FAULT
VZCR
VIOUT
3

Related parts for ACS710KLATR-25CB-T