LM95214CISD National Semiconductor, LM95214CISD Datasheet - Page 25

SENSOR, TEMP, 4-DIODE, 2-WIRE I/F

LM95214CISD

Manufacturer Part Number
LM95214CISD
Description
SENSOR, TEMP, 4-DIODE, 2-WIRE I/F
Manufacturer
National Semiconductor
Datasheet

Specifications of LM95214CISD

Ic Output Type
Current
Sensing Accuracy Range
± 1°C
Supply Current
0.57mA
Supply Voltage Range
3V To 3.6V
Resolution (bits)
11bit
Sensor Case Style
LLP
No. Of Pins
14
Svhc
No SVHC
Temperature Sensing Range
-40°C To +140°C
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LM95214CISD/NOPB
Manufacturer:
NS
Quantity:
8 157
Part Number:
LM95214CISDX/NOPB
Manufacturer:
14
Quantity:
4 211
Part Number:
LM95214CISDX/NOPB
0
Register Name
Status 1 (Diode Fault)
2.4.2 Status 1 Register (Diode Fault)
Status fault bits for open or shorted diode (i.e. Short Fault: D+ shorted to Ground or D-; Open Fault: D+ shorted to V
During fault conditions the temperature reading is 0 °C if unsigned value registers are read or –128.000 °C if signed value registers
are read.
Bit(s)
1
0
Bit(s)
7
6
5
4
3
2
1
0
Bit Name
R4DO
R4DS
R3DO
R3DS
R2DO
R2DS
R1DO
R1DS
Bit Name
SR2F
SR1F
Read/
Write
RO
RO
RO
RO
RO
RO
RO
RO
Read/
Write
RO
RO
Command
Description
Remote 4 diode open fault status:
1 – indicates that remote 4 diode has an "open" fault
0 – indicates that remote 4 diode does not have an "open" fault
Remote 4 diode short fault status:
1 – indicates that remote 4 diode has a "short" fault
0 – indicates that remote 4 diode does not have a "short" fault
Remote 3 diode open fault status:
1 – indicates that remote 3 diode has an "open" fault
0 – indicates that remote 3 diode does not have an "open" fault
Remote 3 diode short fault status:
1 – indicates that remote 3 diode has a "short" fault
0 – indicates that remote 3 diode does not have a "short" fault
Remote 2 diode open fault status:
1 – indicates that remote 2 diode has an "open" fault
0 – indicates that remote 2 diode does not have an "open" fault
Remote 2 diode short fault status:
1 – indicates that remote 2 diode has a "short" fault
0 – indicates that remote 2 diode does not have a "short" fault
Remote 1 diode open fault status:
1 – indicates that remote 1 diode has an "open" fault
0 – indicates that remote 1 diode does not have an "open" fault
Remote 1 diode short fault status:
1 – indicates that remote 1 diode has a "short" fault
0 – indicates that remote 1 diode does not have a "short" fault
(Hex)
Byte
0x07
Description
Status Register 2 Flag:
1 – indicates that Status Register 2 has at least one bit set
0 – indicates that all of Status Register 2 bits are cleared
Status Register 1 Flag:
1 – indicates that Status Register 1 has at least one bit set
0 – indicates that all of Status Register 1 bits are cleared
Read/
Write
RO
R4DO R4DS R3DO R3DS R2DO R2DS R1DO R1DS
D7
25
D6
D5
D4
D3
D2
D1
DD
D0
, or floating).
www.national.com
Default
(Hex)
POR