LM95214CISD National Semiconductor, LM95214CISD Datasheet - Page 26
LM95214CISD
Manufacturer Part Number
LM95214CISD
Description
SENSOR, TEMP, 4-DIODE, 2-WIRE I/F
Manufacturer
National Semiconductor
Datasheet
1.LM95214CISD.pdf
(38 pages)
Specifications of LM95214CISD
Ic Output Type
Current
Sensing Accuracy Range
± 1°C
Supply Current
0.57mA
Supply Voltage Range
3V To 3.6V
Resolution (bits)
11bit
Sensor Case Style
LLP
No. Of Pins
14
Svhc
No SVHC
Temperature Sensing Range
-40°C To +140°C
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
LM95214CISD/NOPB
Manufacturer:
NS
Quantity:
8 157
Company:
Part Number:
LM95214CISDX/NOPB
Manufacturer:
14
Quantity:
4 211
www.national.com
Register Name
Status 2 (TCRIT1)
2.4.3 Status 2 (TCRIT1)
Status bits for TCRIT1. When one or more of these bits are set and if not masked the TCRIT1 output will activate. TCRIT1 will
deactivate when all these bits are cleared.
Bit(s)
7–5
4
3
2
1
0
Bit Name
-
R4T1
R3T1
R2T1
R1T1
LT1
Read/
Write
RO
RO
RO
RO
RO
RO
Command
Description
Reserved – will report "0" when read.
Remote 4 Tcrit Status:
1 – indicates that remote 4 reading is greater than or equal to the value set in Remote 4
Tcrit Limit register
0 – indicates that that remote 4 reading is less than the value set in Remote 4 Tcrit Limit
register minus the Common Hysteresis value
Remote 3 Tcrit Status:
1 – indicates that remote 3 reading is greater than or equal to the value set in Remote 3
Tcrit Limit register
0 – indicates that that remote 3 reading is less than the value set in Remote 3 Tcrit Limit
register minus the Common Hysteresis value
Remote 2 Tcrit-1 Status:
1 – indicates that remote 2 reading is greater than or equal to the value set in Remote 2
Tcrit-1 Limit register
0 – indicates that that remote 2 reading is less than the value set in Remote 2 Tcrit-1 Limit
register minus the Common Hysteresis value
Remote 1 Tcrit-1 Status:
1 – indicates that remote 1 reading is greater than or equal to the value set in Remote 1
Tcrit-1 Limit register
0 – indicates that that remote 1 reading is less than the value set in Remote 1 Tcrit-1 Limit
register minus the Common Hysteresis value
Local Tcrit Status:
1 – indicates that local reading is greater than or equal to the value set in Local Tcrit Limit
register
0 – indicates that local reading is less than the value set in Local Tcrit Limit register minus
the Common Hysteresis value
(Hex)
Byte
0x08
Read/
Write
RO
D7
–
26
D6
–
D5
–
R4T1 R3T1
D4
D3
R2T1
D2
R1T1
D1
LT1
D0
Default
(Hex)
POR
–