HCS300-I/P Microchip Technology, HCS300-I/P Datasheet - Page 10

no-image

HCS300-I/P

Manufacturer Part Number
HCS300-I/P
Description
IC,Remote-Control Transmitter/Encoder,CMOS,DIP,8PIN
Manufacturer
Microchip Technology
Type
Code Hopping Encoderr
Datasheets

Specifications of HCS300-I/P

Applications
Remote Secure Access, Keyless Entry
Mounting Type
Through Hole
Package / Case
8-DIP (0.300", 7.62mm)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HCS300-I/P
Manufacturer:
MICROCHIP
Quantity:
12 000
HCS300
5.0
5.1
The code word completion feature ensures that entire
code words are transmitted, even if the button is
released before the code word is complete. If the but-
ton is held down beyond the time for one code word,
multiple code words will result. If another button is acti-
vated during a transmission, the active transmission
will be aborted and a new transmission will begin using
the new button information.
5.2
During normal transmission the LED output is LOW. If
the supply voltage drops below the low voltage trip
point, the LED output will be toggled at approximately
5Hz during the transmission (Section 3.6.4).
5.3
This bit will be low for the first transmitted word. If a
button is held down for more than one transmitted code
word, this bit will be set to indicate a repeated code
word and remain set until the button is released.
5.4
The V
give an indication to the user that the transmitter bat-
tery is low. The V
sion
transmitted as a zero if the operating voltage is above
the low voltage trip point. Refer to Figure 4-2. The trip
point is selectable based on the battery voltage being
used. See Section 3.6.3 for a description of how the
low voltage trip point is configured.
5.5
The Auto-shutoff function automatically stops the
device from transmitting if a button inadvertently gets
pressed for a long period of time. This will prevent the
device from draining the battery if a button gets
pressed while the transmitter is in a pocket or purse.
This function can be enabled or disabled and is
selected by setting or clearing the Auto-shutoff bit (see
Section 3.5.1). Setting this bit high will enable the func-
tion (turn Auto-shutoff function on) and setting the bit
low will disable the function. Time-out period is approx-
imately 25 seconds.
DS21137F-page 10
LOW
(Figure 4-2
SPECIAL FEATURES
Code Word Completion
RPT: Repeat Indicator
V
Auto-shutoff
LED Output Operation
LOW
signal is transmitted so the receiver can
: Voltage LOW Indicator
LOW
and
bit is included in every transmis-
Figure 8-4)
and
will
be
5.6
In order to increase the level of security in a system, it
is possible for the receiver to implement what is known
as a secure learn function. This can be done by utilizing
the seed value stored in EEPROM, transmitted only
when all four button inputs are pressed at the same
time (Table 5-1). Instead of the normal key generation
inputs being used to create the crypt key, this seed
value is used.
TABLE 5-1:
Hopping Code
Seed Code
Standby
Seed Transmission
PIN ACTIVATION TABLE
Function
13
14
15
0
1
2
-
2001 Microchip Technology Inc.
S3
0
0
0
1
1
1
-
S2
0
0
0
1
1
1
-
S1
0
0
1
0
1
1
-
S0
0
1
0
1
0
1
-

Related parts for HCS300-I/P