MCP3301-BI/MS Microchip Technology, MCP3301-BI/MS Datasheet - Page 21

no-image

MCP3301-BI/MS

Manufacturer Part Number
MCP3301-BI/MS
Description
IC,A/D CONVERTER,SINGLE,13-BIT,TSSOP,8PIN
Manufacturer
Microchip Technology
Datasheet

Specifications of MCP3301-BI/MS

Rohs Compliant
YES
Number Of Bits
13
Sampling Rate (per Second)
100k
Data Interface
Serial, SPI™
Number Of Converters
1
Voltage Supply Source
Single Supply
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
8-TSSOP, 8-MSOP (0.118", 3.00mm Width)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
TMPSNS-RTD1 - BOARD EVAL PT100 RTD TEMP SENSOR
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
MCP3301BI/MS

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MCP3301-BI/MS
Manufacturer:
Microchip
Quantity:
4 000
7.2
Communication with the device is completed using a
standard SPI compatible serial interface. Initiating com-
munication with the MCP3301 begins with the CS
going low. If the device was powered up with the CS pin
low, it must be brought high and back low to initiate
communication. The device will begin to sample the
analog input on the first rising edge of CLK after CS
goes low. The sample period will end in the falling edge
of the second clock, at which time the device will output
a low null bit. The next 13 clocks will output the result
of the conversion with the sign bit first, followed by the
FIGURE 7-2:
FIGURE 7-3:
© 2007 Microchip Technology Inc.
CLK
D
CS
D
OUT
CS
CLK
OUT
t
ACQ
Communicating with the MCP3301
* After completing the data transfer, if further clocks are applied with CS low, the ADC will output LSB first data,
followed by zeros indefinitely. See Figure 7-2 below.
** t
high impedance node, leaving the CLK running to clock out the LSB-first data or zeros.
HI-Z
HI-Z
high impedance node, leaving the CLK running to clock out the LSB-first data or zeros.
DATA
* After completing the data transfer, if further clocks are applied with CS low, the ADC will output zeros indefi-
nitely.
** t
DATA
t
t
ACQ
SUCS
: during this time, the bias current and the comparator power down and the reference input becomes a
t
NULL
SUCS
: during this time, the bias current and the comparator power down and the reference input becomes a
BIT
Communication with MCP3301 (MSB first Format).
Communication with MCP3301 (LSB first Format).
NULL
SB
BIT
B11 B10
SB
B11 B10 B9
B9
B8
t
CONV
B7
B6
B8
B5
t
SAMPLE
B7
t
CONV
B4
B6
B3
B2
B5
B1
t
B4
SAMPLE
12 remaining data bits, as shown in Figure 7-2. Data is
always output from the device on the falling edge of the
clock. If all 13 data bits have been transmitted and the
device continues to receive clocks while the CS is held
low, the device will output the conversion result LSB
first, as shown in Figure 7-3. If more clocks are pro-
vided to the device while CS is still low (after the LSB
first data has been transmitted), the device will clock
out zeros indefinitely.
B0
B3
B1
B2
B2
B3
B1 B0
t
CSH
B4
B5
*
t
DATA
t
Power Down
DATA
B6
**
**
Power
Down
HI-Z
B7
B8
MCP3301
B9 B10
NULL
BIT
SB B11 B10 B9
B11
DS21700C-page 21
t
CSH
SB
*
HI-Z