G6JU-2FSY 5DC Omron, G6JU-2FSY 5DC Datasheet - Page 3

RELAY, SMD, DPDT, 5VDC, LATCHING

G6JU-2FSY 5DC

Manufacturer Part Number
G6JU-2FSY 5DC
Description
RELAY, SMD, DPDT, 5VDC, LATCHING
Manufacturer
Omron
Datasheet

Specifications of G6JU-2FSY 5DC

Contact Current Max
1A
Contact Voltage Ac Nom
125V
Contact Voltage Dc Nom
30V
Coil Voltage Vdc Nom
5V
Coil Resistance
245.5ohm
Coil Power Cont
100mW
Coil Type
DC Coil
Coil Current
20.4mA
Contact Configuration
DPDT
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
G6J-Y
Note:
Note:
Contact resistance (See note 1.)
Operating (set) time (See note 2.)
Release (reset) time (See note 2.)
Minimum set/reset signal width
Insulation resistance (See note 3.)
Dielectric
strength
Impulse
withstand
voltage
Vibration resistance
Shock resistance
Life expectancy
Failure rate (P level) (See note 4.)
Ambient temperature
Ambient humidity
Weight
Characteristics
The above values are initial values.
1. The contact resistance was measured with 10 mA at 1 VDC with a fall-of-potential method.
2. Values in parentheses are actual values.
3. The insulation resistance was measured with a 500-VDC Megger Tester applied to the same parts as those for checking the
4. This value was measured at a switching frequency of 120 operations/min and the criterion of contact resistance is 50 Ω . This
dielectric strength.
value may vary depending on the operating frequency, operating conditions, expected reliability level of the relay, etc. Always
double-check relay suitability under actual load conditions.
Item
Coil and contacts 1,500 VAC, 50/60 Hz for 1 min
Contacts of
different polarity
Contacts of
same polarity
Coil and contacts 2,500 VAC, 2 x 10 µ s
Contacts of
different polarity
Contacts of
same polarity
100 m Ω max.
3 ms max. (approx. 1.6 ms)
3 ms max. (approx. 1.0 ms)
---
1,000 M Ω min. (at 500 VDC)
1,000 VAC, 50/60 Hz for 1 min
750 VAC, 50/60 Hz for 1 min
1,500 VAC, 10 x 160 µ s
Destruction: 10-55-10 Hz 2.5-mm single amplitude (5-mm double amplitude)
Malfunction: 10-55-10 Hz 1.65-mm single amplitude (3.3-mm double amplitude)
Destruction: 1,000 m/s
Malfunction: 750 m/s
Mechanical: 50,000,000 operations min. (at 36,000 operations/hour)
Electrical:
10 µ A at 10 mVDC
− 40 to 85°C (with no icing or condensation)
5% to 85%
Approx. 1.0 g
G6J-2P-Y, G6J-2FS-Y, G6J-2FL-Y
Single-side Stable Relays
100,000 operations min. (with a rated load at 1,800 operations/hour)
2
(approx. 75G)
2
(approx. 100G)
3 ms max. (approx. 0.9 ms)
10 ms
G6JU-2P-Y, G6JU-2FS-Y, G6JU-2FL-Y
Single-winding Latching Relays
G6J-Y
83