Specifications of H3RN-11 12VDC

Contact Configuration
SPCO
Nom Input Voltage
12VDC
Delay Time Range
0.1min To 10h
Timing Adjustment
DIP Switch
No. Of Pins
4
Length/height, External
47.4mm
External Width
12.8mm
External Depth
28.8mm
Relay Mounting
Plug In
H3RN
Specifications
Note: When using the H3RN in any place where the ambient temperature is more than 50"C, supply 90% to 110% of the rated voltages
Time ranges
Rated supply voltage
Pin type
Operating mode
Operating voltage range
Power consumption
Control outputs
Accuracy of operating time
Setting error
Reset time
Influence of voltage
Influence of temperature
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Life expectancy
Impulse withstand voltage
Noise immunity
Static immunity
Enclosure rating
Weight
EMC
Approved standards
Ratings
Characteristics
(12 VDC: 95% to 110% of the rated voltage).
Item
Item
0.1 s to 10 min (1 s, 10 s, 1 min, or 10 min
max. selectable)
24 VAC; 12, 24 VDC
Plug-in
ON-delay, interval, flicker OFF-start, or flicker-ON start selectable by DIP switch
85% to 110% of rated supply voltage (12 VDC: 90% to 110% of rated supply voltage)
(see note)
24 VAC:
12 VDC:
24 VDC:
3 A at 250 VAC, resistive load (cos! = 1) (G6B-2j14P-FD-US used)
The minimum applicable load is 10 mA at 5 VDC (P reference value).
#1% FS max. (1 s range: #1%#10 ms max.)
#15%#50 ms FS max.
Min. power-opening time: 12, 24 VDC: 0.1 s max. (including halfway reset)
#2% FS max.
#2% FS max.
100 M$ min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 min (between operating circuit and control output, or contacts of
different poles)
1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts)
Destruction: 10 to 55 Hz, 0.75-mm single amplitude
Malfunction: 10 to 55 Hz, 0.5-mm single amplitude
Destruction: 300 m/s
Malfunction: 100 m/s
Operating:
Storage:
Operating:
Mechanical: 10,000,000 operations min. (under no load at 1,800 operations/h)
Electrical:
Between power terminals: 1 kV
#1.5 kV, square-wave noise by noise simulator (pulse width: 100 ns/1 %s, 1-ns rise)
Destruction: 8 kV
Malfunction: 4 kV
IP20
Approx. 18 g
Emission Enclosure:
Emission AC Mains:
Immunity ESD:
Immunity RF-interference:
Immunity Conducted Disturbance: ENV50141:
Immunity Burst:
UL508, CSA22.2 No. 14
Conforms to VDE 0435/P2021 (for built-in use)
Conforms to EN50081-2, EN50082-2
Relay ON:
Relay OFF:
Relay ON:
Relay OFF:
Relay ON:
Relay OFF:
--10"C to 55"C (with no icing)
--25"C to 65"C (with no icing)
35% to 85%
100,000 operations min. (3 A at 250 VAC, resistive load at 1,800 operations/h)
H3RN-1/-2
H3RN-1/-2
2
2
(approx. 30G)
(approx. 10G)
approx. 0.8 VA (at 24 VAC, 60 Hz)
0.5 VA (at 24 VAC, 60 Hz)
approx. 0.4 W (at 12 VDC)
0.1 W (at 12 VDC)
approx. 0.5 W (at 24 VDC)
0.2 W (at 24 VDC)
24 VAC:
EN55011 Group 1 class A
EN55011 Group 1 class A
EN61000-4-2: 4 kV contact discharge (level 2)
ENV50140:
EN61000-4-4: 2 kV power-line (level 3)
0.5 s max. (including halfway reset)
0.1 min to 10 h (1 min, 10 min, 1 h, or 10 hrs
max. selectable)
8 kV air discharge (level 3)
10 V/m (amplitude modulated, 80 MHz to
1 GHz) (level 3)
10 V/m (pulse modulated, 900 MHz)
10 V (0.15 to 80 MHz) (level 3)
2 kV I/O signal-line (level 4)
H3RN-11/-21
H3RN-11/-21
H3RN