ON DELAY TIMER, 110VAC

H2C-SA 110AC

Manufacturer Part Number
H2C-SA 110AC
Description
ON DELAY TIMER, 110VAC
Manufacturer
Omron
Datasheet

Specifications of H2C-SA 110AC

Contact Configuration
SPDT
Nom Input Voltage
110VAC
Delay Time Range
1.25s To 30h
Adjustment Type
Knob
Relay Mounting
Panel
Svhc
No SVHC (15-Dec-2010)
Coil Voltage Vac Nom
110V
H2C
Specifications
Five time ranges are available for each timer by turning the time range selector every 60 degrees.
Note: Rated time is displayed on the window.
Note: 1. The front panel of the timer is color coded to identify the following supply voltage classifications:
2
A
B
C
Rated supply voltage
Operating voltage range
Power consumption
Control outputs
Accuracy of operating time
Setting error
Reset time
Influence of voltage
Influence of temperature
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Life expectancy
Motor life expectancy
Approved standards
Weight
Time range code
Time Ranges
Ratings
Characteristics
2. If the voltage continues to be applied after the set time has elapsed, the operating voltage range will change to between 90% and
3. The switching capacity of the control output is 6 A at 250 VAC (cos" = 1). Refer to “Engineering Data” since the electrical service life
100 to 120 V: Blue
200 to 240 V: Red
Other classes: Black
110% of the rated voltage.
of the built-in switch will change in such a case.
Item
1.25 to 30 s
0.2 to 6 s
0.5 to 12 s
100, 110, 115, 120, 200, 220, or 240 VAC (50/60 Hz) (see note 1)
85% to 110% of rated supply voltage (see note 2)
Approx. 3.5 VA
6 A at 250 VAC, resistive load (cos! = 1) (see note 3)
#0.5% max. $#1% max. at 0.2 to 6 s for the time range code B or at 0.5 to 12 s for the time
range code C)
#2% max.
0.5 s max.
#1% max.
#2% max.
100 M% min. (at 500 VDC)
2,500 VAC, 50/60 Hz for 1 min (between current-carrying and non-current-carrying parts)
2,000 VAC, 50/60 Hz for 1 min (between contact and control circuit and between contacts of
different polarities)
1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts)
Destruction: 10 to 55 Hz with 0.75-mm double amplitude
Malfunction: 10 to 55 Hz with 0.5-mm double amplitude
Destruction: 1,000 m/s
Malfunction: 150 m/s
Operating: --10&C to 50&C
Storage:
Operating: 45% to 85%
Mechanical: 10,000,000 operations min.
Electrical:
20,000 hrs
UL (File No. E52800)
H2C series:
H2C-F series: approx. 270 g
7.5 s to 3 min
2 to 60 s
5 to 120 s
--25&C to 65&C
500,000 operations min. (3 A at 250 VAC, resistive load at 1,800 operations/h)
See “Engineering Data”
approx. 180 g
Position of time range selector
2
(approx. 15G)
2
(approx. 100G)
1.25 to 30 min
0.2 to 6 min
0.5 to 12 min
H2C
7.5 min to 3 hrs
2 to 60 min
5 to 120 min
1.25 to 30 hrs
0.2 to 6 hrs
0.5 to 12 hrs
H2C