TR-51666-16 MACROMATIC CONTROLS, TR-51666-16 Datasheet - Page 23

TIME DELAY RELAY, SPDT, 60MIN, 12VAC/DC

TR-51666-16

Manufacturer Part Number
TR-51666-16
Description
TIME DELAY RELAY, SPDT, 60MIN, 12VAC/DC
Manufacturer
MACROMATIC CONTROLS
Datasheet

Specifications of TR-51666-16

Contact Configuration
SPDT
Nom Input Voltage
12V
Delay Time Range
0.6min To 60min
Timing Adjustment
Knob
Relay Mounting
Plug In
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
TIME DELAY RELAYS
TD-8 Series DIP-Switch Digital-Set Plug-in
Application Data & Dimensions For Multi- & Single-Function Products
Programming Function & Time Delay
(TD-881 Series Multi-Function Only)
Programming is accomplished through the use of two
10-position DIP-switches (see drawings at right).
Switches A-D of the left-mounted DIP-switch are
used to select a function (see the descriptions of how
each function operates on Page 73 as a guide).
Switches E-K of the same DIP-switch are used to
select the time base. A convenient chart is on the
side of the relay to clearly illustrate how to set both
the function & time base.
The right-mounted 10-position DIP-switch is used to
select the time delay within the time base selected
with switches E-K from the first DIP-switch. Each
position on the second DIP-switch is marked with a
binary time increment. The required delay is selected by moving the switch of each increment to the ON position &
adding their corresponding values (see diagram at right). Note that dual mode products can either have the same or
different ON & OFF times.
Voltage Tolerance:
AC Operation:
DC Operation:
Load (Burden): 2 VA
Setting Accuracy:
Repeat Accuracy (constant voltage and temperature):
+0.1% of set time or +0.02 seconds, whichever is greater.
Reset Time:
All Functions Triggered by a Control Switch: 0.04 Seconds
All Other Functions: 0.1 Seconds
Start-up Time:
(Time from when power is applied until unit is timing)
120 & 240V units
12, 24 & 48V units
Maintain Function Time:
(Time unit continues to time after power is removed)
0.01 Seconds for all units
Insulation Voltage: 2,000 volts
Dimensions
72
Application Data
+1% of set time or +50ms, whichever is greater.
+10/-15% of nominal at 50/60 Hz.
+10/-15% of nominal.
0.05 Seconds
0.08 Seconds
2.4 (60)
(43)
1.7
Top Image
Temperature: -28
Output Contacts:
DPDT 10A @ 240V AC/30V DC,
1/2HP @ 120/240V AC (N.O.), 1/3HP @ 120V AC (N.C.)
B300 & R300; AC15 & DC13
Life:
Mechanical: 10,000,000 operations
Full Load: 100,000 operations
Compatibility:
Do not use a solid state switch to initiate the timing sequence-
problems with leakage current could occur. Contact Macromatic
Controls for additional information.
Control Switch Triggered Units:
Minimum required trigger switch closure time is 0.02 seconds.
Approvals:
File #E109466
o
to 65
(74)
2.9
o
C (-18
(76)
3.0
o
to 150
Side Nameplate
File #E109466
appropriate
socket
with
o
F)
Inches (Millimeters)
All Dimensions in
1/09