AQZ264 PANASONIC EW, AQZ264 Datasheet

RELAY, PHOTOMOS

AQZ264

Manufacturer Part Number
AQZ264
Description
RELAY, PHOTOMOS
Manufacturer
PANASONIC EW
Datasheet

Specifications of AQZ264

Load Voltage Max
400V
Load Current
1A
On State Resistance Max
1.4ohm
Isolation Voltage
1500V
Forward Current If
50mA
Svhc
No SVHC (15-Dec-2010)
Control Voltage Type
DC
External Depth
9mm
External Length /
RoHS Compliant
Relay Terminals
Through Hole
Rohs Compliant
Yes
TYPES
AC/DC type
* Indicate the peak AC and DC values.
RATING
1) Absolute maximum ratings (Ambient temperature: 25 C
626
Input
Output
Total power dissipation
I/O isolation voltage
Temperature limits
Load voltage
400 V
Max. 43.0
60 V
1.693
LED forward current
LED reverse voltage
Peak forward current
Power dissipation
Load voltage (Peak AC)
Continuous load current (Peak AC)
Peak load current
Power dissipation
Operating
Storage
Output rating*
Item
Max. 32.0
1.260
Max. 9.0
.354
Load current
mm
6.0 A
1.0 A
POWER PhotoMOS RELAYS
(High capacity type)
inch
FEATURES
1. High capacity type power photoMOS
relay.
Can switch a wide range of currents and
voltages. Can control various types of
loads, from very small loads to a maxi-
mum 6A AC/DC current for sequencers,
motors, and lamps.
2. Low ON resistance and high sensi-
tivity.
Low ON resistance of less than 50 mW on
a par with mechanical relays (AQZ262).
High sensitivity LED operate current of 3
mA (at 25 C
3. AC/DC dual use
Bi-directional control is possible. There is
no need to differentiate depending on the
load as was necessary with the conven-
tional SSR.
4. 4-pin SIL type.
4-pin SIL type of (L) 43.0 mm
mm
.354 inch (H) 1.260 inch.
(H) 32.0 mm (L)
Symbol
Viso
Tstg
I
P
T
V
I
P
V
peak
P
I
I
FP
out
opr
F
L
R
in
T
L
77 F
77
AQZ262
AQZ264
Part No.
F)
–40 C to +100 C
).
–40 C to +85 C
AQZ262
10.0 A
6.0 A
60 V
1.693 inch (W)
1,500 V AC
50 mA
75 mA
3.0 W
3.0 W
3 V
1 A
(W) 9.0
–40 F to 185 F
–40 F to 212 F
AQZ264
400 V
1.0 A
3.0 A
Inner carton
20 pcs
PhotoMOS
RELAYS
5. Low-level off state leakage current
In contrast to the SSR with an off state
leakage current of several milliamps, the
PhotoMOS relay features a very small off
state leakage current of only 10mA even
at the rated load voltage.
6. Controls low-level analog signals
The triac, photocoupler, or SSR cannot be
used to control signals of less than sever-
al hundred mV. The high capacity type
power PhotoMOS relay feature extremely
low closed-circuit offset voltage to enable
control of low-level analog signals without
distortion.
TYPICAL APPLICATIONS
• Mercury relay replacement
• Railroad, traffic signals
• Compact motors, lamps, heaters
• OA equipment
• Measurement instruments
f = 100Hz, Duty factor = 0.1%
100 ms (1shot), V
Non-condensing at low temperatures
Packing quantity
Remarks
L
= DC
Outer carton
200 pcs
Pending
UL
Pending
CSA

Related parts for AQZ264

AQZ264 Summary of contents

Page 1

... TYPICAL APPLICATIONS • Mercury relay replacement • Railroad, traffic signals (W) 9.0 • Compact motors, lamps, heaters • OA equipment • Measurement instruments Packing quantity Inner carton 20 pcs AQZ264 Remarks 100Hz, Duty factor = 0. 400 V 1.0 A 3.0 A 100 ms (1shot ...

Page 2

... 100 MHz 4 1,000 M 500 0.5 cps Duty factor = 50 Max resistance vs. ambient temperature char- acteristics LED current: 10 mA; Continuous load current: 6A (DC)(AQZ262) 1A (DC)(AQZ264) 2 1.5 .394 inch 1 0 100 –40 – Ambient temperature, C Remarks = Max. L AQZ264 AQZ262 627 ...

Page 3

... LED forward current vs. turn off time char- acteristics Load voltage (DC); Continuous load current 100 mA (DC); Ambient temperature 0.6 0.5 AQZ262 0.4 0.3 0.2 AQZ264 0 LED forward current, mA 15.-(1) On resistance distribution Sample: AQZ262 LED current: 10 mA; Continuous load current (DC Quantity. n=100; Ambient temperature ...

Page 4

... LED dropout voltage distribution Sample: AQZ264 LED current: 50 mA; Quantity, n=100; Ambient temperature 100 1.28 0 1.24 1.26 1.3 1.32 LED dropout voltage, V AQZ262, 264 16.-(2) Turn on time distribution Sample: AQZ264 Load voltage (DC); Continuous load current: 100 mA (DC); Quantity, n=100; Ambient temperature Turn on time ...

Page 5

... Test time, h 22.-(2) Low temperature storage test (change of on resistance) –40 F Quantity, n=10; Ambient temperature: –40 C AQZ262 2 AQZ264 1.6 1.2 0.8 0 212 F AQZ262 AQZ264 3 10 All Rights Reserved, © Copyright Matsushita Electric Works, Ltd Online Catalog –40 F AQZ262 AQZ264 Test time, h ...

Related keywords