HS9Z-A1 IDEC, HS9Z-A1 Datasheet - Page 4
![Switch Key](/photos/19/43/194323/4438426_sml.jpg)
HS9Z-A1
Manufacturer Part Number
HS9Z-A1
Description
Switch Key
Manufacturer
IDEC
Datasheet
1.HS9Z-A1.pdf
(12 pages)
Specifications of HS9Z-A1
For Use With
HS1E Series Interlock Switches
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Door Interlock Switches
HS1E-4 (Main Circuit: 1NC-1NC, Auxiliary Circuit: 1NO/1NO)
HS1E-14 (Main Circuit: 1NC-1NC, Auxiliary Circuit: 1NO)
Switch/Door
Status
Door
Circuit
Diagram
Main Circuit
Aux. Circuit
Solenoid
Switch/Door
Status
Door
Circuit
Diagram
Main Circuit
Aux. Circuit
Solenoid
1. Main Circuit: used to enable the machine to start only when the main circuit is closed.
2. Auxiliary Circuit: used to indicate whether the machine circuit or door is open or closed.
3. Terminals 7 and 8 are used for the LED indicator, and are isolated from solenoid and door status.
•
•
•
•
•
•
Contacts are linked to
the solenoid mechanically
Contacts are linked to
the solenoid mechanically
Door Closed
Machine ready to operate
Solenoid de-energized
Door Closed
Machine ready to operate
Solenoid de-energized
5-6: Power OFF
5-6: Power OFF
3-4: Closed
3-4: Closed
1-2: Open
1-2: Open
Status 1
Status 1
•
•
•
•
•
•
Door Closed
Machine cannot be started
Solenoid de-energized
Door Closed
Machine cannot be started
Solenoid energized
Contacts are linked to
the solenoid mechanically
Application Examples and Circuit Diagrams
Contacts are linked to
the solenoid mechanically
5-6: Power ON
5-6: Power ON
USA: 800-262-IDEC
1-2: Closed
3-4: Open
3-4: Open
1-2: Open
Status 2
Status 2
•
•
•
•
•
•
Door Opened
Machine cannot be started
Solenoid energized
Door Opened
Machine cannot be started
Solenoid energized
Contacts are linked to
the solenoid mechanically
Contacts are linked to
the solenoid mechanically
5-6: Power ON
5-6: Power ON
Canada: 888-317-IDEC
1-2: Closed
1-2: Closed
3-4: Open
3-4: Open
Status 3
Status 3
•
•
•
•
•
•
Door Opened
Machine cannot be started
Solenoid de-energized
Door Opened
Machine cannot be started
Solenoid de-energized
Contacts are linked to
the solenoid mechanically
Contacts are linked to
the solenoid mechanically
(Note)
5-6: Power OFF
5-6: Power OFF
3-4: Closed
1-2: Closed
1-2: Closed
3-4: Open
Status 4
Status 4
HS1E Series
•
•
•
•
•
•
Door Closed
Machine cannot be started
Solenoid de-energized
Door Closed
Machine cannot be started
Solenoid de-energized
Contacts are linked to
the solenoid mechanically
Unlocked Manually
Contacts are linked to
the solenoid mechanically
Unlocked Manually
5-6: Power OFF
5-6: Power OFF
1-2: Closed
3-4: Open
3-4: Open
1-2: Open
387