HS9Z-A2 IDEC, HS9Z-A2 Datasheet - Page 8

Switch Key

HS9Z-A2

Manufacturer Part Number
HS9Z-A2
Description
Switch Key
Manufacturer
IDEC
Datasheet

Specifications of HS9Z-A2

For Use With
HS1E Series Interlock Switches
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Door Interlock Switches
Actuator Angle Adjustment
Minimum Radius of Hinged Door
HS9Z-A2 Actuator
Using the screw (M3 hex socket head screw), the actuator angle can be
adjusted (refer to the dimensional drawing). Adjustable angle:
(0˚) to 20˚
The larger the adjusted angle of the actuator, the smaller the applicable
radius of the door opening.
When using the interlock switch for a hinged door, refer to the minimum
radius of doors shown below. For the doors with small minimum radius, use
angle adjustable actuators (HS9ZA3 or HS9Z-A3S).
Note: Because deviation or dislocation of hinged door may occur in actual applications, make sure
of the correct operation before installation.
When the door hinge is on the extension line of the actuator mounting
surface:
When the door hinge is on the extension line of the interlock switch surface:
Door Hinge
Door Hinge
HS9Z-A2
Actuator
USA: 800-262-IDEC
Accessories, continued
Canada: 888-317-IDEC
When using the HS9Z-A3 Angle Adjustable (vertical) Actuator
After installing the actuator, open the door. Then adjust the actuator so that
its edge can be inserted properly into the entry slot of the safety switch.
Recommended tightening torque: 0.8 N-m (approx. 8.0 kgf-cm)
After adjusting the actuator angle, apply loctite or the like to the adjustment
screw so as to prevent its loosening.
When the door hinge is on the extension line of the interlock switch surface:
When the door hinge is on the extension line of the actuator mounting
surface:
HS1E Series
HS9Z-A3/A3S
Actuator
391

Related parts for HS9Z-A2