APDS-9300-020 Avago Technologies US Inc., APDS-9300-020 Datasheet - Page 9

IC SENSOR AMBIENT LIGHT 6CHIPLED

APDS-9300-020

Manufacturer Part Number
APDS-9300-020
Description
IC SENSOR AMBIENT LIGHT 6CHIPLED
Manufacturer
Avago Technologies US Inc.
Type
Chipr
Datasheet

Specifications of APDS-9300-020

Wavelength
640nm, 940nm
Output Type
I²C™
Package / Case
6CHIPLED
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 30 C
Output Current
20mA
Sensor Output
Digital
Supply Voltage Range Dc
2.4V To 3V
External Depth
2.2mm
External Width
2.6mm
Leaded Process Compatible
Yes
Length/height, External
0.55mm
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
516-2134-2
Register Set
The APDS-9300 is controlled and monitored by sixteen registers (three are reserved) and a command register accessed
through the serial interface. These registers provide for a variety of control functions and can be read to determine re-
sults of the ADC conversions. The register set is summarized in Table 2.
Table 2. Register Address
The mechanics of accessing a specific register depends on the specific I
protocols. In general, the COMMAND register is written first to specify the specific control/status register for following
read/write operations.
9
Address
--
0h
1h
2h
3h
4h
5h
6h
7h
8h
9h
Ah
Bh
Ch
Dh
Eh
Fh
Register Name
COMMAND
CONTROL
TIMING
THRESHLOWLOW
THRESHLOWHIGH
THRESHHIGHLOW
THRESHHIGHHIGH
INTERRUPT
--
CRC
--
ID
--
DATA0LOW
DATA0HIGH
DATA1LOW
DATA1HIGH
Register Function
Specifies register address
Control of basic functions
Integration time/gain control
Low byte of low interrupt threshold
High byte of low interrupt threshold
Low byte of high interrupt threshold
High byte of high interrupt threshold
Interrupt control
Reserved
Factory test — not a user register
Reserved
Part number/ Rev ID
Reserved
Low byte of ADC channel 0
High byte of ADC channel 0
Low byte of ADC channel 1
High byte of ADC channel 1
2
C protocol used. Refer to the section on I
2
C

Related parts for APDS-9300-020