Specifications of A165E-M-02

Contact Configuration
DPST-NC
Switch Operation
Pushlock Turn Reset
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
30V
Contact Current Max
5A
Actuator Style
Round
Switch Terminals
Solder
Actuator Length
20mm
Ip Rating
IP65
Pole Throw Configuration
DPST
Switch Function Configuration
N.C.
Current Rating (max)
5A
Operating Temp Range
-10C to 55C
Contact Form
DPST - NC
Actuator Diameter
40mm
Svhc
No SVHC
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Note: These E-stop Shrouds are designed for use only in semiconductor manufacturing equipment. Do not use them for any other application.
Specifications
Note: 1. Only models with NC contacts have a direct opening mechanism.
• UL, cUL (File No.E41515)
• TÜV (EN60947-5-1) (Low Voltage Directive)
• CCC (GB14048.5)
Contacts (Standard Load)
Note: 1. Rated current values are determined according to the test-
190
E-stop Shroud (See note.)
E-stop Shroud (See note.)
UL (See note 2.)
TÜV Product Service EN60947-5-1,
CQC (CCC)
KOSHA (See note 3.) EN60947-5-1
10
current
Rated
6A at 220 VAC, 10 A at 110 VAC
3 A at 220VAC
3 A at 240 VAC, 1.5 A at 24 VDC
Certification body
carry
Certified Standards
Certified Standard Ratings
Ratings
2. UL-certification for CSA C22.2 No. 14 and bears the
3. Some models have been certified. Contact your OMRON sales representative.
2. Minimum applicable load: 10 mA at 5 VDC
ing conditions. The above ratings were obtained by conduct-
ing tests under the following conditions.
(1) Ambient temperature: 20 2 C
(2) Ambient humidity: 65 5%
(3) Operating frequency: 20 operations/minute
24 VAC
110 VAC 5
220 VAC 3
380 VAC 2
440 VAC 1
24 VDC
110 VDC
220 VDC
380 VDC
voltage
Rated
Item
10
---
tive load)
(induc-
AC15
UL508
EN60947-5-5
(certified direct opening
mechanism)
GB14048.5
Standards
10
10
6
3
2
---
(resistive
Appearance
Rated current (A)
AC12
load)
---
1.5
0.5
0.2
0.1
tive load)
(induc-
DC13
E41515
Inquire
2003010303070635
2004-220
---
---
File No.
---
10
2
0.6
0.2
(resistive
DC12
load)
Classification
mark.
LED Indicators without Voltage
Reduction Unit
6 VDC
6 VAC
12 VAC/VDC
24 VAC/VDC
Rated voltage
A22Z-EG1
A22Z-EG2
Model
60 mA
60 mA
30 mA
15 mA
Rated current
The SEMI S2-compatible Shroud and
legend plate for EMERGENCY OFF
come as a set. Use with an A22E Emer-
gency Stop Switch.
SEMI-S2/SEMATECH Application Guide
for SEMI 2S-compatible Shroud. Used
together with an A22E Emergency Stop
Pushbutton.
Remarks
6 VDC 5%
6 VAC/VDC 5%
12 VAC/VDC 5%
24 VAC/VDC 5%
Operating voltage