990XCP98000 SQUARE D, 990XCP98000 Datasheet - Page 81

no-image

990XCP98000

Manufacturer Part Number
990XCP98000
Description
QUANTUM CPU BATTERY FOR S
Manufacturer
SQUARE D
Datasheet

Specifications of 990XCP98000

Rohs Compliant
YES
Battery Capacity
1800mAh
Battery Technology
Lithium
Battery Voltage
3V
Battery Terminals
Connector
Weight
0.12lb
Topologies
1
2
3
4
6
7
8
9
10
12
13
52 0422 000
T-connector 2 x RG-11/1 x RG-6 MA 0185 100
RG-6 terminator for T-connector 52 0402 000
RG-11 trunk cable terminator for T-connector
Head-end adaptor 140 CRP 931 00
Head-end adaptor 140 CRP 932 00 (redundant)
RIO drop adaptor 140 CRA 931 00
RIO drop adaptor 140 CRA 932 00 (redundant)
RG-6 coaxial cable (drop)
RG-11 coaxial cable (trunk)
Rack extension module 140 XBE 100 00
Cable for extension module 140 XCA 717 0p
Line length 4.572 km max.
Line length 4.572 km max.
Line length 4.572 km max.
Two F connectors
F connector
52-0401-000
7
Quantum CPU head-end module
7
Quantum CPU head-end module
Local I/O
Local I/O
A T-connector
Modicon
automation platform
I/O architectures
Remote I/O (RIO)
electrically isolate the drop from the trunk cable and to protect the system from
impedance mismatches and cable disconnections. A minimum signal strength
of 14 dB is required between the trunk cable and each I/O drop to help ensure
correct operation. The signal loss on the trunk cable is less than 1 dB as it crosses
a T-connector. A total of 35 dB is available from the head-end RIO CPU. The whole
cabling architecture must not exceed this system limit.
For systems that require high availability, a solution with redundant cable is
available, to provide protection against cable breaks and damaged connectors. With
two cables connected between the host and each drop, the first cable break does not
disrupt communication. If a cable break occurs, a status bit is set to 1 to indicate the
problem drop or the faulty cable. For preventive maintenance, the system also
provides retry counters for all communication transactions to all drops. High retry
counts on a cable in a specific drop could indicate connection problems. This will
enable corrective work to be scheduled before there is unwanted downtime.
RIO drop 1
RIO drop 1
Topologies
Single-cable topology
RIO topology with redundant cable
10
10
Two cables
per drop
1
2
10
3
4
MA 0185 100 is required for each I/O drop on the system to
6
®
RIO drop 2
RIO drop 2
Quantum
9
9
8
8
RIO drop 2 extension
RIO drop 2 extension
12
12
12
8
8
4
Last RIO drop
Last RIO drop
13
13
3
3/5
0
10
10
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9

Related parts for 990XCP98000