SF2-24V PANASONIC EW, SF2-24V Datasheet - Page 5

RELAY, FORCED CONTACT, DPCO, 24VDC

SF2-24V

Manufacturer Part Number
SF2-24V
Description
RELAY, FORCED CONTACT, DPCO, 24VDC
Manufacturer
PANASONIC EW
Datasheet

Specifications of SF2-24V

Coil Voltage Vdc Nom
24V
Coil Resistance
1.152kohm
Contact Current Max
6A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
30V
No. Of Poles
2
Relay Mounting
PC Board
External Width
25mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SF2-24V
Manufacturer:
SIEMENS
Quantity:
12 000
2) 3a1b Type
If the form “b” contact (No. 3) welds, the armature becomes non-operational, the contact gaps at the three form “a” contacts are
maintained at greater than 0.5 mm
When the form “a” contacts (No. 1, 2, or 4) weld, the armature remains in a non-returned state and the contact gap at the single form
“b” contact is maintained at greater than 0.5 mm
The table below shows the state of the other contacts when the current through the welded form “a” contact is 0 V and the rated
voltage is applied through the form “b” contact.
For Cautions for Use, see Relay Technical Information
No.4
No.3
No.4
No.3
No.4
No.3
Terminal No.
Contact No.
Contact Operation Table
Form “b” Contact Weld
Form “a” Contact Weld
Non-energized
11–12
No.1
Energized
No.2
7–8
No.3
5–6
9–10
No.4
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
No.1
No.2
No.1
No.2
No.1
No.2
.020
inch. Reliable isolation is thus ensured
Note: Contact gaps are shown at the initial state.
If the contacts change state owing to loading/breaking
it is necessary to check the actual loading.
Contact No.
terminal
Welded
.020
No.4
No.3
No.4
No.3
Non-energized (when no. 2 contact is welded)
No.
Energized (when no. 3 contact is welded)
Contact No.
inch. Reliable isolation is thus ensured.
1
2
3
4
>0.5
1
State of other contacts
>0.5
2
>0.5
>0.5
>0.5
3
No.1
No.2
No.1
No.2
>0.5
4
If the No. 3 contact welds.
Each of the three form “a” contacts (No. 1, 2,
and 4) maintain a gap of greater than 0.5 mm
.020
If the No. 2 contact welds.
The single form “b” contact (No. 3) maintains a
gap of greater than 0.5 mm
Empty cells: either closed or open
>0.5: contact gap is kept at
inch.
min. 0.5 mm
.020 inch
.020
inch.
SF