Specifications of IM-T-11A

Supply Voltage Max
24VDC
Control Output Type
2NO/1NC
If arc suppressors are used, they MUST
be installed across the actuator coil of the
machine primary control elements (MPCE1,
MPCE2). NEVER install suppressors
directly across the output contacts of
the Interface Module. It is possible for
suppressors to fail as a short circuit. If
installed directly across the output contacts
of the Interface Module, a short-circuited
suppressor will create an unsafe condition
which could result in serious injury or death.
Banner Engineering Corp.
Banner Engineering Corp.
WARNING . . .
Use of Arc Suppressors
www.bannerengineering.com • Tel: 763.544.3164
www.bannerengineering.com • Tel: 763.544.3164
Minneapolis, MN U.S.A.
Minneapolis, MN U.S.A.
Figure 5. Generalized hookup to a 2-channel primary safety device with two hard-contact safety
Figure 6. Generalized hookup to a 2-channel primary safety device with two current-sourcing
+24V dc
+24V dc
Machine
Control
outputs and one monitoring contact feedback input
safety outputs and two monitoring inputs
Machine
Control
Feedback (optional)
S3
S4
13
23
33
Feedback (optional)
Primary
Safety
Device
Output
Safety
+
S3
S4
13
23
33
K2
K2
IM-T-9A
Output
Safety
Primary
Safety
Device
Safety Output
+
K2
K2
IM-T-9A
Safety Output
EDM
K1
K1
+
+
EDM2
EDM1
K1
K1
S1
S2
Y1
Y2
Y3
Y4
14
24
34
MPCE2 MPCE1
S1
S2
Y1
Y2
Y3
Y4
14
24
34
MPCE
2
Reset
MPCE2
MPCE
MPCE
2
1
MPCE1
MPCE
1
0V dc
0V dc
NOTE: Although this hookup shows model
NOTE: Although this hookup shows model
IM-T-9A, the hookup for model
IM-T-11A is identical.
IM-T-9A, the hookup for model
IM-T-11A is identical.