37000 Simpson, 37000 Datasheet

Current Transducer

37000

Manufacturer Part Number
37000
Description
Current Transducer
Manufacturer
Simpson
Type
Inductiver
Datasheets

Specifications of 37000

Current Measuring Range Ac
0A To 5A
Supply Voltage Range Dc
21.6V To 26.4V
Sensor Output
Current
Frequency Max
60Hz
Transducer Output Current Dc Max
20mA
Length
69.85mm
Frequency Min
60Hz
Accuracy
0.5%
Frequency Response
60 Hz
Function
Current
Height
4.22 in.
Material, Stud
Brass
Output
Current
Primary Type
Current
Range, Measurement
5 A
Technology
Inductive
Width
0.071 in.
Equipment Type
Current Transducer
Range
0 - 5
Accuracy %
0.5%
Current Range Ac
0-5A
Current Range Dc
4-20mA
External Depth
59.94mm
Rohs Compliant
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
For Use With
Digital DC process panel indicators and controllers
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
37000
Manufacturer:
DES
Quantity:
1 030
Part Number:
37000200000
Manufacturer:
Littelfuse
Quantity:
40 000
Part Number:
37000400000
Manufacturer:
WICKMANN
Quantity:
3 150
Part Number:
37000500430
Manufacturer:
SANDISK
Quantity:
1 500
Part Number:
37000500430
Manufacturer:
ITT
Quantity:
200

Related parts for 37000

37000 Summary of contents

Page 1

...

Page 2

... Lindbergh’s historic solo trans-Atlantic flight in 1927 to the digital controllers used to raise and lower stages at the 2004 MTV Video Music Awards (VMAs) show or the MiniMax meters which monitor the lighting at CNN, Simpson continues to pro- vide solutions for a wide variety of electrical, electronic and environmental testing and measuring applications ...

Page 3

... Quick Disconnect Assemblies Metal Transition Assemblies Compression Fitting Shunts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C3 Switchboard External Portable Current Transformers . . . . . . . . . . . . . . .C4-C6 Donut Current Transformers Terminal Type Transformers Model 186 Current Transformer Model 183 Multipliers . . . . . . . . . . . . . . . . . .C7 Current Transducers . . . . . . . . . . . . . . . . . . .C7 1/8 DIN NEMA 4X Removable Cover . . . . .C8 Bezel Kits . . . . . . . . . . . . . . . . . . . . . . . . . . .C8 DIN Rail Mounting Kit . . . . . . . . . . . . . . . . . .C1 ...

Page 4

... Digital panel meters, such as the Simpson Hawk 3, offer scaling (the capability of the meter to asso- ciate, in engineering units, any desired value to the elec- trical input range) ...

Page 5

... A 12-pin connector with 6" wire leads is included with each unit for quick installation. Specifications DISPLAY Type Height Decimal point Overrange indication Backlighting Polarity POWER REQUIREMENTS DC Power Power supply current Backlight supply current ACCURACY @ 25°C ENVIRONMENTAL Operating Temperature Storage Temperature Relative Humidity Warmup time Temperature Coefficient NOISE REJECTION NMRR CMRR ...

Page 6

A 2 Ordering Information Mini Indicators can be configured by making an entry in each section. Example: M135-0-2-11-0 Selection M135 M145 Installation and Panel Cutout Basic Display DPM Power Function/ Unit Supply Description Selection Basic ...

Page 7

... U U nique m m ounting b b racket a a llows s s tacking ultiple u u nits • crew t t erminal c c onnectors asy installation • igit isplay w w ith optional n n egative acklighting Inputs AC TRMS Voltage AC TRMS Current Range Resolution Voltage Max Input Range Resolution Drop (Unfused) 200µA 100µ ...

Page 8

A 4 Ordering Information Mini-Max Indicators can be configured by making an entry in each section. Example: M245-1-0-71-0. Selection M235 M245 Not Available on ...

Page 9

DIN Temperature Indicator • Jumper-selectable input type and ºC/ºF indication • Screw terminal connectors for easy installation • Unique mounting bracket allows for stacking of multiple meters Dimensions - M235, M245 & M240 2.66” Specifications DISPLAY Type Height ...

Page 10

A 6 Ordering Information Mini-Max Indicators can be configured by making an entry in each section. Example: M240-0-91-0-F. Selection M240 Mounting Requirements Insert the Mini-Max through the panel, and then slide the mount- ing bracket ...

Page 11

... F45 DC Current ±0.05% of reading ±1 count 2A ± 5 counts F35 DC Current ±0.1% of reading ± 1 count 2A ± 5 counts (45Hz-1KHz) F45 AC Voltage/Current ±0.5% of reading ± 35 counts (45Hz-1KHz) F35 AC Voltage/Current ±1% of reading ± 5 counts (45Hz-1KHz) ENVIRONMENTAL Operating Temperature 0 to 55°C Storage Temperature -10 to 60°C Relative Humidity ...

Page 12

... Less than 20 minutes and S Platinum 100 (.00385 alpha wire ±84mV reading of uncompensated mV 0.1°C/°C 10MW(typical) 4.0µV/100W 2-1/2 times per second -1 on display, -40nA bias on thermocouple AC/AC TRMS Current Input Maximum Input Voltage Range Resolution Drop >100M 50V ...

Page 13

... Hz Sq. Wave 94 (F35) 20-1999 Hz Sq. Wave (not available with AC, temperature, or frequency inputs) 0 None 1 12 DCV @ 25mA max. current 2 24 DCV @ 25mA max. current C ° ° Meets CE EMI EN-50082-1, EN-55022, EN-61000-3-2, EN-61000-3-3 (temp. units only) Description Excitation Output Display Scaling ...

Page 14

... Temp. Coefficient Warmup time CONVERSION Technique Rate MECHANICAL Bezel Depth Panel cutout Weight Ordering Information Maximum Input 100M 100M 10M 10M DC Current Range Display Maximum Resolution Input 20µA 10µA 20mA 200µA 100µA 20mA 2mA 1mA 20mA 20mA 10µA 100mA ...

Page 15

... DC Volts High (600 V) 0.1% ± 1 count All others 0.05% ± 1 count Resistance All ranges 0.1% ± 2 counts *AC Current High (2A, 5A) 0.2% ± 2 counts All others 0.1% ± 2 counts *AC Volts High (600V) 0.1% ± 1 count All others 0.05% ± 1 count * AC functions measured at 50 Hz, include ± ...

Page 16

A 12 Ordering Information Hawk 3 Indicators can be configured by making an entry into each section. Example: H335-3-71-0-4-1 Basic Unit Selection H335 H345 1 120 ACV (3-1/2 only) 2 85-250 ACV (4-1/2 only) 9-36 DCV 3 85-250 ACV (3-1/2 ...

Page 17

... Function/Range 2 Two 4 Four 91 J Thermocouple 92 K Thermocouple Excitation 93 RTD, PT100 3-wire 0 None 94 E Thermocouple 1 12 DCV - 100mA max current 95 T Thermocouple 2 24 DCV - 100mA max current Specifications DISPLAY Type Quantity Height Brightness Overrange indication Underrange indication Sensor Break Excitation POWER REQUIREMENTS AC DC ACCURACY @ 25° ...

Page 18

... Overload 4.5 3.5 Impedance 200µ 11mA .1µ 100 35mA 1µ 111mA DC 200 mA 10 µ 353 .013 .013 Current Range Resolution Resolution Input Overload 4.5 3.5 Impedance 200µ 11mA .1µ 100 35mA 1µ 111mA AC 200 mA 10 µ 353mA .013 .013 ...

Page 19

... VA ±1% Rdg 120%FS ±0.6%FS var ±1.5% Rdg 120%FS ±0.8%FS PF ±2% Rdg* Frequency ±0.2° Neutral Current 5% to 120%FS Wh Register N/A VAh Register N/A Varh Register N/A N/A N/A Note: All accuracies specified are ±1 digit *Rdg = Reading MECHANICAL Bezel 2.77” ...

Page 20

... GIMA 300 Meter 300 GIMA 400 Meter 400 Power Supply 1 115 VAC @ 45-65Hz 2 230 VAC @ 45-65 Hz Voltage Input 1 120/208V 2 120/240V - Split Phase 3 277/480V 4 63/110V Current Input 5 amp 1 Other 0 None For other Voltage and Current Inputs, contact Simpson Electric Company Other ...

Page 21

... The Options Module provides four DC current sinks with a common signal return which allows connection to PLCs and other equipment fitted with a suitable interface. 4-20mA systems are commonly used where signals require transmission over long distances ...

Page 22

... PBT-ABS 9oz (255.1g) Output Power Supply None 1 0 120 ACV One Relay 2 1 240 ACV Two Relays 2 Excitation Input None Standard 1 12DCV Quadrature 2 (100mA max current) Other None ...

Page 23

... Panel Cutout Case Material Weight Other 0 None Excitation None 0 12DCV 1 Panel Cutout Dimensions on page A23 (100mA max current) Typical Min. Input Update Period Frequency 1.0 sec 1Hz 0.5 sec 2Hz 3 sec 20 Counts/Min 1.2 Million Counts/Min 90 sec 40 Counts/Hr 3.0 Million Counts/Hr 6-digit, 7-segment, red LED 0.56" ...

Page 24

... Height Decimal Point Count Direction Display Range Output Indicators POWER REQUIREMENTS AC Voltages Power Consumption INPUT RATINGS Current Sinking Current Sourcing Minimum Pulse Width Low Pass Filter Low Bias High Bias Count Rate Maximum Voltage Input A, B, and User INPUT User Input ...

Page 25

... Panel Cutout 3.62" x 1.77" (92mm x 45mm) Case Material PBT-ABS Weight 9oz (255.1g) Ordering Information Output Power Supply None 0 120 ACV 1 One Relay 1 240 ACV 2 Two Relays 2 Input Basic Unit S663 Standard 1 Quadrature 2 (100mA Max Current Other None 0 Excitation None 0 12DCV 1 ...

Page 26

... PBT-ABS 9oz (255.1g) Output Power Supply 0 None 120 ACV 1 240 ACV 2 Excitation Input Standard 1 Quadrature 2 100mA Max Current Other None 0 0 None 1 12DCV ...

Page 27

... One flexible coupling (1/2” I.D.) and three reducing inserts (1/4”, 5/16”, 3/8”). A Simpson 12” anodized aluminum measuring wheel is the right choice to complete the setup of a length measurement system. Whether the application requires one or two, Simpson’s measuring wheels will perform accurately and reliably throughout the measuring process ...

Page 28

... To aid in troubleshooting, LEDs are located directly on the body to instantly verify correct output operation. Quadrature output is standard and can be externally scaled to provide any engineering unit (RPM, angular position, feet/min., etc.). Gold-plated connectors ensure max- imum signal transfer. Very low power consumption; typical current draw, 35mA @ 15DCV. Specifications DISPLAY ...

Page 29

... Simpson Electric offers a wide range of reliable and durable analog panel meters to fulfill your application require- ments. Our products continue to set the standard for quality with each of our analog panel meter families. Century • Rugged black plastic case • Glass window for optimum viewing Round / Rectangular • ...

Page 30

... Calibration is unaffected by magnetic panel mounting. 1.5 seconds maximum 10 times F.S. 1.5 times F.S. 2%: AC Current, DC Process 3%: AC Voltage, DC Voltage, Wattmeters 0.5%: DC Current Sharp clear scale. Each dial arc is calibrated to track the specific type of movement used. +15% of meter impedance -4°F to +149°F (-20°C to +65°C) High density black plastic Model 1212: Black lance ...

Page 31

Model 1379 4-1/2"-Model 1329, 1329T, 1349, 1359 (2) #1/4-28 STUD 4-1/2"-Model 1389 3-1/2"-Model 1327, 1327T, 1347, 1357 B 3 ...

Page 32

... Available on special order * These meters require use of an external current transformer from page C5. AC Voltmeters, , 4-1/2” 3-1/2” Range Model 1359 Model 1357 0-5 06625 06665 0-10 06630 ...

Page 33

... Note 2: AC load meters must be used with external donut transformers. Complete instruc- tions for proper selection are included with each AC load meter. Advance assistance in selecting the appropriate transformer and determining the correct primary/secondary turns ratio can be obtained from a Simpson technical service representative or authorized service center. 4-20mA Process Meters Size 4-1/2" ...

Page 34

B 6 • Glass window for optimum viewing • Rugged black plastic case • Black knife-edge pointer for precision reading Frequency Meter Specifications Accuracy 45-55Hz ±0.3Hz (120V-240V) 55-65Hz ±0.3Hz (120V-240V) 380-420Hz ±1.2Hz (120V-240V) Movement Small core magnet, self-shielding Suspension Pivot ...

Page 35

Dimensions 1-1/2"-Models 2121, 2121T, 2141, MTG HOLES-.125 DIA DRILL THRU 3-1/2"-Models 2123, 2123T, 2143, 2153, 2183 4-1/2"-Model 2174 = Panel Meter Cut-out Dimensions 1 2-1/2"-Models 2122, 2122T, 2142, 2152,2182 3-1/2"-Model 2173 4-1/2"-Model 2124, 2124T, 2144, 2154, 2184 (4) #6-32 MTG. ...

Page 36

... Available on special order. †These meters are 5-amp meters used with an external current transformer. AC Dual Range Ammeter/Voltmeter, Model/Size and Catalog Number Approx. 2-1/2" Impedance (ohms Model Hz 2152 Range 15,030 ...

Page 37

... Model 2124T DC (Note 17585 AC (Note 2) 5 amps 17586 1. These DC meters require an external shunt from page C3, and wire-wound potentiometer (customer supplied). 17587 2. These AC meters require use of a current transformer from page C5. 17588 17590 Frequency Meters, 17592 Approx. Impedance 17594 <> (Ohms)@ Range ...

Page 38

B 10 • Clear acrylic case updates panel design • Black knife-edge pointer for precision reading • Special colored scales or logos available Dimensions 1-1/2"-Model 921, 921T, 941 2-1/2"-Model 922, 942 Specifications Accuracy: Movement: Suspension: Tracking: Repeatability: Shielding: Response Time: ...

Page 39

... TV3AAA075* 0-100 0.008 TV3AAA100* 0.008 0-150 TV3AAA150* 0.008 0-200 TV3AAA200* 0.008 0-300 TV3AAA300* * These meters require use of a current transformer from pages C4-C6 AC Voltmeters, Iron Vane Movement Approx. Model/Size and Catalog Number Impedance 3-1/2" (ohms) @ Model 953 Range 60 Hz 0-5 TV3AVV005 ...

Page 40

... TV1DAA5T5* TV2DAA5T5 1/2” DC current meters are self-contained through 10 amps; 15 amps and higher are supplied as 50mV meters and require an external shunt from page C3. 2 1/2”, 3 1/2” and 4 1/2” meters are self-contained through 50 amps. Higher ranges are 50 mV meters and require an external shunt from page C3 ...

Page 41

... Available on special order. * These meters require use of an external current transformer from page C4-C6 4-20mA Process Meters, Dial indicates 0-100 Percent Approx. Impedance Model/Size and Catalog number (Ohms) Range 4-20 5.0 B ...

Page 42

... Model 45 75-0-75 08010 * DC current meters are self-contained for ranges up to and including 50 amperes. Higher range DC current meters (50 mV) listed above are calibrated for 5' leads and require external shunts. <> Available on special order. 2-1/2" 3-1/2" DC Millivoltmeters, Model 125 ...

Page 43

Panel Meter Cut-out Dimensions NOTE: “T” model suffix used for Taut-Band movement 2-1/2"-Models 125, 125T, 145, 155, & 185 3-1/2"-Models 25 & 25T, 45, 55, 75, 85 & Model 25 Process Meter 3-1/2"-Model 75 .16 DIA. DRILL THRU. ...

Page 44

B 16 • Plastic case with Glass Window • Calibration not affected when mounted on steel • Three popular sizes: 2-1/2”, 3-1/2”, 4-1/2” Specifications Accuracy ±2% full scale (F.S.) (iron-vane), ±3% (rectifier) Wattmeters: ±2%F.S.; Compensated meters: ±3%F.S. Movement Models 57, ...

Page 45

Dimensions 3-1/2"-Models 27 & 27T, 47, 57, & 1/2”-Model 29, 29T, 49, 59, 79 & 89 2-1/2"-Model 177 3-1/2"-Model 1/2”-Model 79 2-1/2"-Model 127 & 127T, 147, 157, & 187 MTG. Holes - .140 DIA ...

Page 46

... Model 27 Model 29 † DC current meters are self-contained for ranges up to and including 50 amperes. Higher range DC current meters (50 mV) listed above are calibrated 06930 06950 for 5'. leads and require external shunts. 06940 <> Available on special order. ...

Page 47

Ordering Information AC Microammeters Rectifier Type, Self Shielding Movement Model/Size and Catalog Number Approx. Impedance 2-1/2" (ohms Range Model 147 Model 47 0-100 3400 < > 0-200 2400 < > 0-300 1800 < > 0-500 1200 < ...

Page 48

... Requires external current transformer from page C3-C4 4-1/2” Model 554 15121 15120 15122 15123 15125 15124 15127† 15128† ...

Page 49

Ordering Information AC Voltmeters, Iron-Vane Movement Model/Size and Catalog Number Approx. Impedance 3-1/2” Range (Ohms) @60Hz Model 553 0-150* 25,000 15060 0-250* 41,166 15061 0-300* 50,000 15062 *Rectifier movements are available on special order. DC Microammeters, Self-Shielding Movement Model/Size and ...

Page 50

B 22 • Rugged metal case for rigorous environments • Splash-proof and sealed against moisture, dust and dirt • Calibration not affected by steel panel mounting • O-Ring sealed zero adjust and electrical terminals Specifications Accuracy: ±3% F.S. AC Rectified, ...

Page 51

Ordering Information AC Microammeter Rectifier Type, Self-Shielding Movement Model/Size and Catalog Number Approx. Impedance 3-1/2” (ohms) @ 60Hz Range Model 3343 <> 4,000 0-100 <> Available on special order. AC Milliammeter Rectifier Type, Self-Shielding Movement Model/Size and Catalog Number Approx. ...

Page 52

B 24 Model 1357ET/Wide-Vue Model 112ET Model 55ET/Round Model 109ET Model 2153ET/Century Model 57ET/Rectangular ...

Page 53

Record “on” time of electrical equipment • No reset capability means virtually tamper- proof • Choice models • 2 sizes and 6 different case styles Dimensions 1-1/2"- Model 109ET 3 - 1/2”- Model 55ET 3 ...

Page 54

B 26 1-1/2"- Model 112ET = 1 Panel Meter Cut-out Dimensions 3 - 1/2”-Model 2153ET Specifications Accuracy: Models 109ET & 112ET; <.01%/24HRS. Models 55ET, 57ET, 1357ET & 2153ET: Synchronous with AC power Movement: Synchronous clock motor Overload (1 sec.): 10 ...

Page 55

Excellent readability -- more than double the scale length of standard movements • Sealed round metal or square plastic cases with glass windows • Zero adjust from front panel Specifications Accuracy: AC: ±3% full scale (F.S.) DC: ±2% full ...

Page 56

... Model 2543 0-5 ACA Motor Load 0.5VA Maximum* Current** * Internal transformer burden ** Dial reads 0-150% Motor Load Current < > Available on special order AC Voltmeters Rectifier Type, Model/Size and Catalog Number Approx. Impedance 3-1/2” Range (Ohms) @ 60Hz Model 2543 0-10 ...

Page 57

Wide Variety of Control, Alarm, and Limit Use • Calibration Not Affected by Steel Panel Mounting • Rugged Metal Case for Rigorous Environments • Commercially-Sealed, Moisture and Dust Proof Dimensions 4 - 1/2”-Model 3344AIXA & 3324AIXA = 1 Panel ...

Page 58

... Percent Motor Load 21680 21640 21682 21642 Scale 0-150%* 0-150%** 0-150%** 4-1/2” Model * Use with Model 186 current transformers, pages C4-C6 3324AIXA ** Use with current transformers, page C4 Single Set point Dual (High Limit) Set point Temperature Meters <> <> Specifications ...

Page 59

... DIN Rail Mounting Bracket • Fits Simpson Hawk 3, Falcon and Counters • Fits Standard Din Rail Ordering Information Din Rail Adapter Specifications Enclosure: UL94V-0 Rated ABS Attachment Clips: Spring Steel Stiffeners: Steel Installed depth: 4.20” from top of DIN Rail to front of ...

Page 60

Thermocouples/RTD Quick Disconnect Assemblies C 2 Ordering Information Type ANSI Color Code Black J Yellow K Note: All selections include standard plug and jack connectors. Specifications 316 Stainless Steel Best corrosion resistance of the stainless steel grades. Good corrosion resistance ...

Page 61

Shunts Portable 150 amp Catalog No. 06714 Switchboard 100 amp Catalog No. 06500 Ordering Information Switchboard 50mV Shunts Portable 50mV Shunts Range Cat. Number Range Cat. Number 100 06500 1 06700 150 06503 5 06703 200 06504 10 06704 ...

Page 62

... Current Transformers Model 186 Current Transformer C 4 • Optimal for remote sensing of AC current signals • Converts AC current signal to 0-10 ACV signal • For use with rectifier type analog panel meters or digital indicators • Perfect for low current measurement where a donut current transformer would ...

Page 63

... Donut Current Transformers Donut Current Transformers • Meets A.S.A C57.13 Standard •Flexible leads are UL105, 105°C CSA approved • Molded from impact and abrasive resist- ance black nylon for rugged construction • ±2% Accuracy Catalog Number Turns Ratio 01293 10:1 ...

Page 64

... The ratio of the current transformer can be modified by altering the number of secondary turns by forward or backwinding the secondary lead through the window of the current transformer. By adding second- ary turns, the same primary current will result in a decrease in second- ary output. By subtracting turns, the same primary current will result in greater secondary output. ...

Page 65

... X 0.50” 4.50” 0.44” 2.75” 0.75” 1.25” DIA 4.88” 2.25” 3.50” Output Current Range(DCmA) Catalog Number 4-20mA 37000 4-20mA 37001 4-20mA 37002 4-20mA 37003 4-20mA 37004 4-20mA 37005 4-20mA 37006 C ...

Page 66

DIN NEMA 4 Removable Cover • Protects 1/8 DIN indicators and controllers • Dust tight and water tight to NEMA 4 C standards 8 • Removable front cover allows access to programming buttons or scaling potentiometers Dimensions Specifications Lens ...

Page 67

Digital Products Feature Reference Guide Feature Mini Size: 3/64 DIN 1/8 DIN 1/4 DIN Display: LCD LCD Backlit LED Resolution: 3.5 digit 4.5 digit 4 digit Temperature 6 digit Power Supply: ACV DCV 9 DCV Battery Inputs ...

Page 68

...

Related keywords