37000 Simpson, 37000 Datasheet - Page 44

Current Transducer

37000

Manufacturer Part Number
37000
Description
Current Transducer
Manufacturer
Simpson
Type
Inductiver
Datasheets

Specifications of 37000

Current Measuring Range Ac
0A To 5A
Supply Voltage Range Dc
21.6V To 26.4V
Sensor Output
Current
Frequency Max
60Hz
Transducer Output Current Dc Max
20mA
Length
69.85mm
Frequency Min
60Hz
Accuracy
0.5%
Frequency Response
60 Hz
Function
Current
Height
4.22 in.
Material, Stud
Brass
Output
Current
Primary Type
Current
Range, Measurement
5 A
Technology
Inductive
Width
0.071 in.
Equipment Type
Current Transducer
Range
0 - 5
Accuracy %
0.5%
Current Range Ac
0-5A
Current Range Dc
4-20mA
External Depth
59.94mm
Rohs Compliant
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
For Use With
Digital DC process panel indicators and controllers
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
37000
Manufacturer:
DES
Quantity:
1 030
Part Number:
37000200000
Manufacturer:
Littelfuse
Quantity:
40 000
Part Number:
37000400000
Manufacturer:
WICKMANN
Quantity:
3 150
Part Number:
37000500430
Manufacturer:
SANDISK
Quantity:
1 500
Part Number:
37000500430
Manufacturer:
ITT
Quantity:
200
16
B
• Plastic case with Glass Window
• Calibration not affected when mounted on
• Three popular sizes: 2-1/2”, 3-1/2”, 4-1/2”
Accuracy
Movement
Suspension
Tracking
Shielding
Response Time
Overload (1 sec.)
Overload
(Continuous)
Repeatability
Dial
Resistance
Pointer
Scale Length
Net Weight
Specifications
Wattmeters:
steel
±2% full scale (F.S.) (iron-vane), ±3% (rectifier)
±2%F.S.; Compensated meters: ±3%F.S.
Models 57, 59, 157 Iron-vane, magnetically damped
Wattmeters: Dynamometer
All others: Annular, rectifier type, self-shielding
Pivot and jewel; “T” styles: taut band
±3%
Calibration is unaffected by magnetic panel mounting
1.5 seconds maximum
10 times F.S.
1.5 times F.S.
2%, tautband: .5%
Sharp clear scale. Each dial arc is calibrated to track
the specific type of movement used
±15% of meter impedance
Spade pointer with black, matte finish
Models 177 & 157: 1.6” (40.6mm)
Models 147, 127 & 127T: 1.8” (45.7mm)
Models 57 & 77: 2.3” (58.4mm)
Models 27, 27T, & 47: 2.5” (63.5mm)
Models 59 & 79: 3.50” (89.0mm)
Models 29, 29T, & 49: 3.9” (99.0mm)
Models 57 & 157: 5oz (0.14kg)
Models 127, 127T & 147: 7oz (0.20kg)
Models 27, 27T, 47 & 59: 8oz (0.23kg)
Models 77 & 177: 9oz (0.26kg)
Models 29, 29T & 49: 11oz (0.31kg)
Model 79: 12oz (0.34kg)
Accuracy
Movement
Suspension
Shielding
Center Scale Value
Power Consumption
Warm-up Time
Max. Input:
Voltage (10 sec)
Dial
Case
Operating
Temperature
Pointer:
Scale Length:
Net Weight:
Frequency Meter Specifications
45-55Hz ±0.3Hz (120V-240V)
55-65Hz ±0.3Hz (120V-240V)
380-420Hz ±1.2Hz (120V-240V)
Small core magnet, self-shielding
Pivot and jewel
Calibration is unaffected by magnetic panel mounting
50/60/400Hz
1.6VA
5 minutes
150, 120V normal
280, 240V normal
Sharp clear scale. Each dial arc is calibrated to track
the specific type of movement used
High density black plastic
-4°F to +149°F (-20°C to +65°C)
Spade pointer with black, matte finish
Model 187: 1.8” (45.7mm)
Model 89: 3.5” (89.0mm)
Model 87: 3.9” (99.0mm)
Model 187: 5oz (0.14kg)
Model 87: 8oz (0.23kg)
Model 89: 11oz (0.31kg)