SM91EANQD BANNER ENGINEERING, SM91EANQD Datasheet - Page 8

no-image

SM91EANQD

Manufacturer Part Number
SM91EANQD
Description
Photoelectric Sensor
Manufacturer
BANNER ENGINEERING
Datasheet

Specifications of SM91EANQD

Output Current
150mA
Sensor Output
NPN/PNP
Supply Voltage Range Dc
10V To 30V
Peak Reflow Compatible (260 C)
No
Sensor Input
Optical
Sensing Range Max
30m
Leaded Process Compatible
No
334
VALU-BEAM
Supply Voltage and Current
Output Configuration
Output Rating
Output Protection Circuitry
Output Response Time
Repeatability
Adjustments
Indicators
Construction
Environmental Rating
Connections
Operating Conditions
Application Notes
Certifications
Supply Protection Circuitry
®
912 Series Sensors
24 to 250V ac (50/60 Hz), except for SMA91E, ESR and EF emitters, which operate from 10 to 250V ac or dc
Protected against transient voltages
SPST SCR solid-state relay with either normally closed or normally open contact (light/dark operate
selectable); 2-wire hookup
Minimum load current 10 mA, max. steady-state load capability 750 mA to 50°C ambient (122°F), 500 mA
to 70°C ambient (158°F)
Inrush capability 4 amps for 1 sec. (non-repetitive)
Off-state leakage current less than 1.7 mA rms
On-state voltage drop 5 volts rms at 750 mA load, 10 volts rms at 15 mA load
Protected against false pulse on power-up
8 milliseconds ON and OFF (except receiver-only units, which are 8 milliseconds 0N and 4 milliseconds
OFF; independent of signal strength
OFF time does not include load response of up to
Response time specification of the load should be considered when important
(NOTE: 300 millisecond delay on power-up; outputs are non-conducting during this time)
Opposed and Glass Fiber Optic Emitter-Receiver pairs: 1.0 millisecond; Retro, Diffuse, Convergent and
Glass Fiber Optic: 2.6 milliseconds
LIGHT/DARK OPERATE select switch and SENSITIVITY control potentiometer, both located at rear of sensor
Top-mounted red LED indicator lights when output is conducting. Models SMA91E & SM91ESR emitter
have a visible-red “tracer beam” which indicates “power on” and enables easy “line-of-sight” alignment.
Reinforced thermoplastic polyester housing, totally encapsulated, molded acrylic lenses and stainless
steel hardware
Meets NEMA standards 1, 2, 3, 3S, 4, 4X, 12 and 13; IEC IP66
PVC-jacketed 2 m (6.5') or 9 m (30') cables or 3-pin mini-style quick-disconnect (QD) fitting available.
See page 368 and the Accessories section.
Temperature:
Maximum relative humidity: 90% at 50°C (non-condensing)
i) 912 Series ac sensors may be destroyed from overload conditions
ii) Use on low voltage requires careful analysis of the load to determine if the leakage current or on-state
iii) The false-pulse protection feature may cause momentary drop-out of the load when the sensor is
wired in series or parallel with mechanical switch contacts
voltage of the sensor will interfere with proper operation of the load
Banner Engineering Corp. • Minneapolis, U.S.A. • www.bannerengineering.com • Tel: 763.544.3164
912 Series AC Specifications
-20° to +70° C (-4° to +158°F)
1
/
2
ac cycle (8.3 milliseconds)

Related parts for SM91EANQD