XS1N08PA349 TELEMECANIQUE, XS1N08PA349 Datasheet - Page 38

PROXIMITY SWITCH, M8, PNP

XS1N08PA349

Manufacturer Part Number
XS1N08PA349
Description
PROXIMITY SWITCH, M8, PNP
Manufacturer
TELEMECANIQUE
Type
Inductiver
Datasheets

Specifications of XS1N08PA349

Frequency Response Max
2.5kHz
Sensing Range Max
2.5mm
Sensor Input
Inductive
Supply Voltage Dc Max
24V
Connector Type
Pre-Wired
Contact Current Max
200mA
External Length / Height
33mm
Body Style
Cylindrical
Current, Switching
200 mA
Frequency, Operating
2500 Hz
Function
Proximity
Ip Rating
IP67
Length, Cable
2 m
Material, Housing
Nickel Plated Brass
Mounting Style
Shielded-(Extended Range)
Mounting Type
M8 Threaded
Output
PNP-NO
Primary Type
Proximity
Range, Measurement
2.5 mm
Technology
Inductive
Temperature Range
-25 to +70 °C
Termination
3-Wire Cable
Voltage, Supply
24 VDC
BN/1
BU/3
Accessories :
page 3/59
Flush mountable in metal
Lengths (mm) :
a = Overall
b = Threaded section
Nominal sensing distance (Sn)
References
3-wire a PNP
2-wire c
Weight (kg)
Characteristics
Connection (2)
Degree of protection
Operating temperature (1)
Output state indication
Voltage limits (including ripple)
Switching capacity
Voltage drop, closed state
Current consumption, no-load
Maximum switching frequency
Wiring schemes
3-wire a
(1) Other operating temperature ranges : - 40…+ 70 C (To order, add suffix TF to above refs.), - 25…+ 85 C (To order, add suffix TT to above refs.).
(2) Sensors pre-cabled with other cable lengths :
Length of cable
5 m
10 m
Example : sensor XSA-V11373 with 5 m cable becomes XSA-V11373L05
Other versions
PNP
BK/4
b
a
+
Impulses/minute
6…150
120…3000
Impulses/minute
6…150
120…3000
Inductive proximity sensors
For specific applications : rotation monitoring
Cylindrical type, metal case
References, characteristics, dimensions, schemes
a = 81
b = 57
Ø = M30 x 1.5
10 mm
XSA-V11373
XSA-V12373
0.300
Pre-cabled, 3 x 0.34 mm
length 2 m
IP 67
- 25…+ 70 C
LED
a 10…58 V
0…200 mA with overload
& short-circuit protection
6000 impulses/minute (for XSA-V11iii) ; 48,000 impulses/minute (for XSA-V12 iii)
2-wire c
Suffix to be added to references stated above
L05
L10
Sensors without initial “run-up” delay, or with reduced “run-up” delay on energisation of 3 seconds.
SX2-DV units for monitoring overspeed or underspeed conditions, in the range 0 to 6000 impulses/
minute.
Please consult your Regional customer centre.
1.8 V
10 mA
BU
BN
2
,
10 mm
XSA-V11151
XSA-V12151
0.300
Pre-cabled, 2 x 0.5 mm
c 93…132 V
20…350 mA
(2 A inrush)
4.5 V
2
, length 2 m
10 mm
XSA-V11161
XSA-V12161
0.300
c 187…264 V
Te
Weight increase
0.120 kg
0.320 kg
3/57
3

Related parts for XS1N08PA349