32.1135-10021 MC (MULTI CONTACT), 32.1135-10021 Datasheet - Page 45

no-image

32.1135-10021

Manufacturer Part Number
32.1135-10021
Description
CABLE ASSLY, M-F, PV, 4MM, 1M
Manufacturer
MC (MULTI CONTACT)
Datasheet

Specifications of 32.1135-10021

Cable Assembly Type
Low Voltage
Connector Type A
Plug
Connector Type B
Socket
Cable Length
1m
Cable Type
FLEX-SOL-XL
Outer Insulation Colour
Black
Svhc
No SVHC (15-Dec-2010)
Cable Length - Metric
1m
Jacket Colour
Black
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Advanced Contact Technology
Derating Diagramm
Temperaturabhängigkeit der Strom-
belastbarkeit
Die folgende Kurve zeigt die Abhängigkeit
der Strombelastbarkeit der FLEX-SOL-XL
Leitungen von der Umgebungstempera-
tur gemäss 2 PfG 1169 / 08.07.
100% entsprechen jeweils dem ange-
gebenen Bemessungsstrom.
Technische Hinweise
Crimpanschlüsse
Für den Leiteranschluss an die Crimphül-
sen der PV-Steckverbinder empfehlen
wir die angegebenen Crimpwerkzeuge
einzusetzen. Für UL zugelassene Produk-
te können nur die erwähnten Werkzeuge
für die Selbstmontage gemäss den Mon-
tageanleitungen verwendet werden. Die
Crimphülsen sind für flexible Leiter (Klas-
se 5 und 6) der genannten Querschnitts-
bereiche ausgelegt. Der Einsatz mehr-
drähtiger Leiter (Klasse 2) ist möglich.
Verzinnte Leiter sind vorteilhaft.
Anschlussleitung
Zur Sicherstellung einer ausreichenden
Dichtheit
PV-Steckverbinder sind Anschlussleitun-
gen in den, den Isolationsgehäusen zu-
gewiesenen, Durchmesserbereichen ein-
zusetzen.
Verlegebedingungen
Ein scharfkantiges Abbiegen der An-
schlussleitung am Ausgang der PV-Steck-
verbinder ist beim Verlegen der PV-Lei-
tungen zu vermeiden. Wir empfehlen die
Mindestbiegeradien der Anschlussleitung
einzuhalten.
des
120 %
100 %
80 %
60 %
40 %
20 %
0 %
Leitungsausgangs
20
30
Umgebungstemperatur / Ambient temperature / Température ambiante
65
55
45
35
25
15
5
1
info
2
40
3
4
5
Diverse Testreihen
6
7
8
9
10 11 12 13 14 15 16 17 18
Zeit in h
der
19 20
50
Derating diagram
Temperature-dependence of Current-
carrying Capacity
The following curve shows the correlation
between the current-carrying capacity of
the FLEX-SOL-XL cable and the ambient
temperature according to 2 PfG 1169 /
08.07.
100% corresponds to the rated current
stated.
Technical information
Crimped terminations
For termination of the conductors to the
crimping sleeves of the PV plug connec-
tors we recommend using the stated
crimping tools. For UL certified products
only the tools mentioned can be used
for self-assembly according to the as-
sembly
sleeves are designed for highly flexible
conductors of the stated cross-section
ranges. The use of flexible conductors is
possible. It is advantageous to use
tinned conductors.
Connecting cables
To ensure that the cable outlets of the
PV plug connectors are sufficiently wa-
tertight, connecting cables of the speci-
fied diameter ranges for the insulating
casings must be used.
Laying conditions
When laying the PV leads, avoid having
the connecting cable resting on a sharp
edge at the exit from the PV connector.
We recommend observing the mini-
mum bending radius of the connecting
cables.
60
www.multi-contact.com
70
instructions.
80
The
90
crimping
65
55
45
35
25
15
5
100
info
1
2
3
4
5
Diverse Testreihen
6
7
8
9
Zeit in h
10 11 12 13 14 15 16 17 18
19 20
110
Diagramme de derating
Intensité en fonction de la tempéra-
ture
La courbe suivante présente l’évolution
de
FLEX-SOL-XL en fonction de la tempéra-
ture ambiante selon 2 PfG 1169 / 08.07.
100% correspond à l’intensité nominale
spécifiée.
Informations techniques
Le sertissage
Pour le raccordement des câbles sur les
connecteurs PV, nous recommandons
l’utilisation des outils de sertissage spé-
cifiés. Pour les produits certifiés UL,
seuls les outils mentionnés peuvent
être utilisés selon les instructions de
montage. Les fûts à sertir sont dimen-
sionnés pour des conducteurs ex-
tra-souples de section spécifiée. L’utili-
sation de conducteurs souples est
possible.
offrent des avantages.
Câble de raccordement
Afin de garantir un niveau d’étanchéité
suffisant au niveau de la sortie de câble
des connecteurs PV, il convient d’utili-
ser des câbles dont le diamètre sur iso-
lant est compatible avec le capuchon
isolant du connecteur.
Conditions d’installation
Au niveau du connecteur PV, éviter
toute sortie de câble à angle vif. Veiller à
respecter le rayon minimal de courbure
prescrit.
120
FLEX-SOL-XL
l’intensité
130
Les
140
admissible
conducteurs
150
du
160
65
55
45
35
25
15
5
info
1
étamés
2
3
4
5
Diverse Testreihen
6
7
câble
8
9
10 11 12 13 14 15 16 17 18
Zeit in h
45
T
°C
19 20

Related parts for 32.1135-10021